275 related articles for article (PubMed ID: 25324103)
1. Tissue harmonic synthetic aperture ultrasound imaging.
Hemmsen MC; Rasmussen JH; Jensen JA
J Acoust Soc Am; 2014 Oct; 136(4):2050-6. PubMed ID: 25324103
[TBL] [Abstract][Full Text] [Related]
2. Clinical evaluation of synthetic aperture harmonic imaging for scanning focal malignant liver lesions.
Brandt AH; Hemmsen MC; Hansen PM; Madsen SS; Krohn PS; Lange T; Hansen KL; Jensen JA; Nielsen MB
Ultrasound Med Biol; 2015 Sep; 41(9):2368-75. PubMed ID: 26095533
[TBL] [Abstract][Full Text] [Related]
3. Sequential beamforming for synthetic aperture imaging.
Kortbek J; Jensen JA; Gammelmark KL
Ultrasonics; 2013 Jan; 53(1):1-16. PubMed ID: 22809678
[TBL] [Abstract][Full Text] [Related]
4. An Adaptive Synthetic Aperture Method Applied to Ultrasound Tissue Harmonic Imaging.
Varnosfaderani MHH; Mohammadzadeh Asl B; Faridsoltani S
IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Apr; 65(4):557-569. PubMed ID: 29610086
[TBL] [Abstract][Full Text] [Related]
5. Dual stage beamforming in the absence of front-end receive focusing.
Bera D; Bosch JG; Verweij MD; de Jong N; Vos HJ
Phys Med Biol; 2017 Jul; 62(16):6631-6648. PubMed ID: 28604358
[TBL] [Abstract][Full Text] [Related]
6. In vivo evaluation of synthetic aperture sequential beamforming.
Hemmsen MC; Hansen PM; Lange T; Hansen JM; Hansen KL; Nielsen MB; Jensen JA
Ultrasound Med Biol; 2012 Apr; 38(4):708-16. PubMed ID: 22390993
[TBL] [Abstract][Full Text] [Related]
7. In-vivo evaluation of convex array synthetic aperture imaging.
Pedersen MH; Gammelmark KL; Jensen JA
Ultrasound Med Biol; 2007 Jan; 33(1):37-47. PubMed ID: 17189045
[TBL] [Abstract][Full Text] [Related]
8. Clinical evaluation of synthetic aperture sequential beamforming ultrasound in patients with liver tumors.
Hansen PM; Hemmsen M; Brandt A; Rasmussen J; Lange T; Krohn PS; Lönn L; Jensen JA; Nielsen MB
Ultrasound Med Biol; 2014 Dec; 40(12):2805-10. PubMed ID: 25308936
[TBL] [Abstract][Full Text] [Related]
9. A Primer on the Physical Principles of Tissue Harmonic Imaging.
Anvari A; Forsberg F; Samir AE
Radiographics; 2015; 35(7):1955-64. PubMed ID: 26562232
[TBL] [Abstract][Full Text] [Related]
10. Comparing differential tissue harmonic imaging with tissue harmonic and fundamental gray scale imaging of the liver.
Chiou SY; Forsberg F; Fox TB; Needleman L
J Ultrasound Med; 2007 Nov; 26(11):1557-63. PubMed ID: 17957050
[TBL] [Abstract][Full Text] [Related]
11. Ultrasound research scanner for real-time synthetic aperture data acquisition.
Jensen JA; Holm O; Jensen LJ; Bendsen H; Nikolov SI; Tomov BG; Munk P; Hansen M; Salomonsen K; Hansen J; Gormsen K; Pedersen HM; Gammelmark KL
IEEE Trans Ultrason Ferroelectr Freq Control; 2005 May; 52(5):881-91. PubMed ID: 16048189
[TBL] [Abstract][Full Text] [Related]
12. Intravascular Ultrasound Transducer by Using Polarization Inversion Technique for Tissue Harmonic Imaging: Modeling and Experiments.
Sung JH; Jeong EY; Jeong JS
IEEE Trans Biomed Eng; 2020 Dec; 67(12):3380-3391. PubMed ID: 32286955
[TBL] [Abstract][Full Text] [Related]
13. Compounding in synthetic aperture imaging.
Hansen JM; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Sep; 59(9):2054-65. PubMed ID: 23007781
[TBL] [Abstract][Full Text] [Related]
14. Imaging with concave large-aperture therapeutic ultrasound arrays using conventional synthetic-aperture beamforming.
Wan Y; Ebbini ES
IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Aug; 55(8):1705-18. PubMed ID: 18986915
[TBL] [Abstract][Full Text] [Related]
15. Development of Dual-Frequency Oblong-Shaped-Focused Transducers for Intravascular Ultrasound Tissue Harmonic Imaging.
Lee J; Shin EJ; Lee C; Chang JH
IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Sep; 65(9):1571-1582. PubMed ID: 29994203
[TBL] [Abstract][Full Text] [Related]
16. Three-dimensional synthetic aperture focusing using a rocking convex array transducer.
Andresen H; Nikolov SI; Pedersen MM; Buckton D; Jensen JA
IEEE Trans Ultrason Ferroelectr Freq Control; 2010 May; 57(5):1051-63. PubMed ID: 20442016
[TBL] [Abstract][Full Text] [Related]
17. Empirical mode decomposition and tissue harmonic imaging.
Bennett M; McLaughlin S; Anderson T; McDicken N
Ultrasound Med Biol; 2005 Aug; 31(8):1051-61. PubMed ID: 16085096
[TBL] [Abstract][Full Text] [Related]
18. Investigation of the effect of subcutaneous fat on image quality performance of 2D conventional imaging and tissue harmonic imaging.
Browne JE; Watson AJ; Hoskins PR; Elliott AT
Ultrasound Med Biol; 2005 Jul; 31(7):957-64. PubMed ID: 15972201
[TBL] [Abstract][Full Text] [Related]
19. Short-lag Spatial Coherence Ultrasound Imaging with Adaptive Synthetic Transmit Aperture Focusing.
Zhao J; Wang Y; Yu J; Guo W; Zhang S; Aliabadi S
Ultrason Imaging; 2017 Jul; 39(4):224-239. PubMed ID: 28068874
[TBL] [Abstract][Full Text] [Related]
20. Pulse inversion sequences for mechanically scanned transducers.
Frijlink ME; Goertz DE; de Jong N; van der Steen AF
IEEE Trans Ultrason Ferroelectr Freq Control; 2008 Oct; 55(10):2154-63. PubMed ID: 18986864
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]