These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

140 related articles for article (PubMed ID: 25330783)

  • 1. Effects of spot size and spot spacing on lateral penumbra reduction when using a dynamic collimation system for spot scanning proton therapy.
    Hyer DE; Hill PM; Wang D; Smith BR; Flynn RT
    Phys Med Biol; 2014 Nov; 59(22):N187-96. PubMed ID: 25330783
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A dynamic collimation system for penumbra reduction in spot-scanning proton therapy: proof of concept.
    Hyer DE; Hill PM; Wang D; Smith BR; Flynn RT
    Med Phys; 2014 Sep; 41(9):091701. PubMed ID: 25186376
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The dosimetric enhancement of GRID profiles using an external collimator in pencil beam scanning proton therapy.
    Smith BR; Nelson NP; Geoghegan TJ; Patwardhan KA; Hill PM; Yu J; Gutiérrez AN; Allen BG; Hyer DE
    Med Phys; 2022 Apr; 49(4):2684-2698. PubMed ID: 35120278
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Toward improved target conformity for two spot scanning proton therapy delivery systems using dynamic collimation.
    Moignier A; Gelover E; Smith BR; Wang D; Flynn RT; Kirk ML; Lin L; Solberg TD; Lin A; Hyer DE
    Med Phys; 2016 Mar; 43(3):1421-7. PubMed ID: 26936726
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design of a focused collimator for proton therapy spot scanning using Monte Carlo methods.
    Geoghegan TJ; Nelson NP; Flynn RT; Hill PM; Rana S; Hyer DE
    Med Phys; 2020 Jul; 47(7):2725-2734. PubMed ID: 32170750
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy.
    Nelson NP; Culberson WS; Hyer DE; Geoghegan TJ; Patwardhan KA; Smith BR; Flynn RT; Yu J; Rana S; Gutiérrez AN; Hill PM
    Med Phys; 2021 Jun; 48(6):3172-3185. PubMed ID: 33740253
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fan-beam intensity modulated proton therapy.
    Hill P; Westerly D; Mackie T
    Med Phys; 2013 Nov; 40(11):111704. PubMed ID: 24320412
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Optimization of proton pencil beam positioning in collimated fields.
    Behrends C; Bäumer C; Verbeek NG; Wulff J; Timmermann B
    Med Phys; 2023 Apr; 50(4):2540-2551. PubMed ID: 36609847
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Patient-specific quality assurance of dynamically-collimated proton therapy treatment plans.
    Bennett LC; Hyer DE; Vu J; Patwardhan K; Erhart K; Gutierrez AN; Pons E; Jensen E; Ubau M; Zapata J; Wroe A; Wake K; Nelson NP; Culberson WS; Smith BR; Hill PM; Flynn RT
    Med Phys; 2024 Sep; 51(9):5901-5910. PubMed ID: 38977285
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy.
    Nelson NP; Culberson WS; Hyer DE; Smith BR; Flynn RT; Hill PM
    Biomed Phys Eng Express; 2022 Feb; 8(2):. PubMed ID: 35130520
    [No Abstract]   [Full Text] [Related]  

  • 11. Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy.
    Smith BR; Pankuch M; Hyer DE; Culberson WS
    Med Phys; 2020 Oct; 47(10):5343-5356. PubMed ID: 33411329
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Theoretical Benefits of Dynamic Collimation in Pencil Beam Scanning Proton Therapy for Brain Tumors: Dosimetric and Radiobiological Metrics.
    Moignier A; Gelover E; Wang D; Smith B; Flynn R; Kirk M; Lin L; Solberg T; Lin A; Hyer D
    Int J Radiat Oncol Biol Phys; 2016 May; 95(1):171-180. PubMed ID: 26614424
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Contour scanning, multi-leaf collimation and the combination thereof for proton pencil beam scanning.
    Winterhalter C; Meier G; Oxley D; Weber DC; Lomax AJ; Safai S
    Phys Med Biol; 2018 Dec; 64(1):015002. PubMed ID: 30523928
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Implication of spot position error on plan quality and patient safety in pencil-beam-scanning proton therapy.
    Yu J; Beltran CJ; Herman MG
    Med Phys; 2014 Aug; 41(8):081706. PubMed ID: 25086516
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An analytical dose-averaged LET calculation algorithm considering the off-axis LET enhancement by secondary protons for spot-scanning proton therapy.
    Hirayama S; Matsuura T; Ueda H; Fujii Y; Fujii T; Takao S; Miyamoto N; Shimizu S; Fujimoto R; Umegaki K; Shirato H
    Med Phys; 2018 Jul; 45(7):3404-3416. PubMed ID: 29788552
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy.
    Nelson NP; Culberson WS; Hyer DE; Geoghegan TJ; Patwardhan KA; Smith BR; Flynn RT; Yu J; Gutiérrez AN; Hill PM
    Phys Med Biol; 2023 Feb; 68(5):. PubMed ID: 36706460
    [No Abstract]   [Full Text] [Related]  

  • 17. Optimizing mini-ridge filter thickness to reduce proton treatment times in a spot-scanning synchrotron system.
    Courneyea L; Beltran C; Tseung HS; Yu J; Herman MG
    Med Phys; 2014 Jun; 41(6):061713. PubMed ID: 24877808
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of spot parameters in pencil beam scanning treatment planning.
    Kraan AC; Depauw N; Clasie B; Giunta M; Madden T; Kooy HM
    Med Phys; 2018 Jan; 45(1):60-73. PubMed ID: 29148575
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of minimum monitor unit threshold on spot scanning proton plan quality.
    Howard M; Beltran C; Mayo CS; Herman MG
    Med Phys; 2014 Sep; 41(9):091703. PubMed ID: 25186378
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Technical Note: A treatment plan comparison between dynamic collimation and a fixed aperture during spot scanning proton therapy for brain treatment.
    Smith B; Gelover E; Moignier A; Wang D; Flynn RT; Lin L; Kirk M; Solberg T; Hyer DE
    Med Phys; 2016 Aug; 43(8):4693. PubMed ID: 27487886
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.