These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 25331565)

  • 1. Reducing the radiation dose for computed tomography colonography using model-based iterative reconstruction.
    Millerd PJ; Paden RG; Lund JT; Hara AK; Stiles WL; He M; Wu Q; Johnson CD
    Abdom Imaging; 2015 Jun; 40(5):1183-9. PubMed ID: 25331565
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Model-based Iterative Reconstruction in Low-radiation-dose Computed Tomography Colonography: Preoperative Assessment in Patients with Colorectal Cancer.
    Taguchi N; Oda S; Imuta M; Yamamura S; Nakaura T; Utsunomiya D; Kidoh M; Nagayama Y; Yuki H; Hirata K; Iyama Y; Funama Y; Baba H; Yamashita Y
    Acad Radiol; 2018 Apr; 25(4):415-422. PubMed ID: 29191684
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Standard and reduced radiation dose liver CT images: adaptive statistical iterative reconstruction versus model-based iterative reconstruction-comparison of findings and image quality.
    Shuman WP; Chan KT; Busey JM; Mitsumori LM; Choi E; Koprowicz KM; Kanal KM
    Radiology; 2014 Dec; 273(3):793-800. PubMed ID: 25170546
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of hybrid and pure iterative reconstruction techniques with conventional filtered back projection: dose reduction potential in the abdomen.
    Singh S; Kalra MK; Do S; Thibault JB; Pien H; O'Connor OJ; Blake MA
    J Comput Assist Tomogr; 2012; 36(3):347-53. PubMed ID: 22592622
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sub-milliSievert (sub-mSv) CT colonography: a prospective comparison of image quality and polyp conspicuity at reduced-dose versus standard-dose imaging.
    Lubner MG; Pooler BD; Kitchin DR; Tang J; Li K; Kim DH; Munoz del Rio A; Chen GH; Pickhardt PJ
    Eur Radiol; 2015 Jul; 25(7):2089-102. PubMed ID: 25903700
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Model-based iterative reconstruction in low-dose CT colonography-feasibility study in 65 patients for symptomatic investigation.
    Vardhanabhuti V; James J; Nensey R; Hyde C; Roobottom C
    Acad Radiol; 2015 May; 22(5):563-71. PubMed ID: 25683499
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study.
    Flicek KT; Hara AK; Silva AC; Wu Q; Peter MB; Johnson CD
    AJR Am J Roentgenol; 2010 Jul; 195(1):126-31. PubMed ID: 20566805
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Image comparative assessment using iterative reconstructions: clinical comparison of low-dose abdominal/pelvic computed tomography between adaptive statistical, model-based iterative reconstructions and traditional filtered back projection in 65 patients.
    Vardhanabhuti V; Riordan RD; Mitchell GR; Hyde C; Roobottom CA
    Invest Radiol; 2014 Apr; 49(4):209-16. PubMed ID: 24368613
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of a model-based, iterative reconstruction algorithm (MBIR) regarding image quality and dose reduction in liver computed tomography.
    Chang W; Lee JM; Lee K; Yoon JH; Yu MH; Han JK; Choi BI
    Invest Radiol; 2013 Aug; 48(8):598-606. PubMed ID: 23511193
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ultralow-dose CT of the craniofacial bone for navigated surgery using adaptive statistical iterative reconstruction and model-based iterative reconstruction: 2D and 3D image quality.
    Widmann G; Schullian P; Gassner EM; Hoermann R; Bale R; Puelacher W
    AJR Am J Roentgenol; 2015 Mar; 204(3):563-9. PubMed ID: 25714286
    [TBL] [Abstract][Full Text] [Related]  

  • 11. One-mSv CT colonography: Effect of different iterative reconstruction algorithms on radiologists' performance.
    Shin CI; Kim SH; Im JP; Kim SG; Yu MH; Lee ES; Han JK
    Eur J Radiol; 2016 Mar; 85(3):641-8. PubMed ID: 26860679
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Image quality improvement using model-based iterative reconstruction in low dose chest CT for children with necrotizing pneumonia.
    Sun J; Yu T; Liu J; Duan X; Hu D; Liu Y; Peng Y
    BMC Med Imaging; 2017 Mar; 17(1):24. PubMed ID: 28302073
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reducing the Radiation Dose for CT Colonography: Effect of Low Tube Voltage and Iterative Reconstruction.
    Yamamura S; Oda S; Imuta M; Utsunomiya D; Yoshida M; Namimoto T; Yuki H; Kidoh M; Funama Y; Baba H; Yamashita Y
    Acad Radiol; 2016 Feb; 23(2):155-62. PubMed ID: 25872861
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography.
    Lambert L; Ourednicek P; Jahoda J; Lambertova A; Danes J
    Br J Radiol; 2015 Apr; 88(1048):20140667. PubMed ID: 25605346
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultra-low-dose CT of the lung: effect of iterative reconstruction techniques on image quality.
    Yanagawa M; Gyobu T; Leung AN; Kawai M; Kawata Y; Sumikawa H; Honda O; Tomiyama N
    Acad Radiol; 2014 Jun; 21(6):695-703. PubMed ID: 24713541
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Adaptive statistical iterative reconstruction and Veo: assessment of image quality and diagnostic performance in CT colonography at various radiation doses.
    Yoon MA; Kim SH; Lee JM; Woo HS; Lee ES; Ahn SJ; Han JK
    J Comput Assist Tomogr; 2012; 36(5):596-601. PubMed ID: 22992612
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms.
    Vardhanabhuti V; Loader RJ; Mitchell GR; Riordan RD; Roobottom CA
    AJR Am J Roentgenol; 2013 Mar; 200(3):545-52. PubMed ID: 23436843
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Model-based iterative reconstruction compared to adaptive statistical iterative reconstruction and filtered back-projection in CT of the kidneys and the adjacent retroperitoneum.
    Olcott EW; Shin LK; Sommer G; Chan I; Rosenberg J; Molvin FL; Boas FE; Fleischmann D
    Acad Radiol; 2014 Jun; 21(6):774-84. PubMed ID: 24809318
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Submillisievert chest CT with filtered back projection and iterative reconstruction techniques.
    Padole A; Singh S; Ackman JB; Wu C; Do S; Pourjabbar S; Khawaja RD; Otrakji A; Digumarthy S; Shepard JA; Kalra M
    AJR Am J Roentgenol; 2014 Oct; 203(4):772-81. PubMed ID: 25247943
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of dose reduction and image quality in CT colonography: comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection.
    Nagata K; Fujiwara M; Kanazawa H; Mogi T; Iida N; Mitsushima T; Lefor AT; Sugimoto H
    Eur Radiol; 2015 Jan; 25(1):221-9. PubMed ID: 25097128
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.