These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

225 related articles for article (PubMed ID: 25343223)

  • 1. Comparison of hinge microflow fields of bileaflet mechanical heart valves implanted in different sinus shape and downstream geometry.
    Kuan YH; Kabinejadian F; Nguyen VT; Su B; Yoganathan AP; Leo HL
    Comput Methods Biomech Biomed Engin; 2015; 18(16):1785-96. PubMed ID: 25343223
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Numerical analysis of the hemodynamic performance of bileaflet mechanical heart valves at different implantation angles.
    Kuan YH; Nguyen VT; Kabinejadian F; Su B; Kim S; Yoganathan AP; Leo HL
    J Heart Valve Dis; 2014 Sep; 23(5):642-50. PubMed ID: 25799715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of hinge gap width on the microflow structures in 27-mm bileaflet mechanical heart valves.
    Leo HL; Simon HA; Dasi LP; Yoganathan AP
    J Heart Valve Dis; 2006 Nov; 15(6):800-8. PubMed ID: 17152788
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A numerical investigation of blood damage in the hinge area of aortic bileaflet mechanical heart valves during the leakage phase.
    Yun BM; Wu J; Simon HA; Arjunon S; Sotiropoulos F; Aidun CK; Yoganathan AP
    Ann Biomed Eng; 2012 Jul; 40(7):1468-85. PubMed ID: 22215278
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simulation of the three-dimensional hinge flow fields of a bileaflet mechanical heart valve under aortic conditions.
    Simon HA; Ge L; Borazjani I; Sotiropoulos F; Yoganathan AP
    Ann Biomed Eng; 2010 Mar; 38(3):841-53. PubMed ID: 19960368
    [TBL] [Abstract][Full Text] [Related]  

  • 6. An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flow.
    Saxena R; Lemmon J; Ellis J; Yoganathan A
    J Thorac Cardiovasc Surg; 2003 Jul; 126(1):90-8. PubMed ID: 12878943
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve design.
    Leo HL; He Z; Ellis JT; Yoganathan AP
    J Thorac Cardiovasc Surg; 2002 Sep; 124(3):561-74. PubMed ID: 12202873
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of heart rate on the hemodynamics of bileaflet mechanical heart valves' prostheses (St. Jude Medical) in the aortic position and in the opening phase: A computational study.
    Jahandardoost M; Fradet G; Mohammadi H
    Proc Inst Mech Eng H; 2016 Mar; 230(3):175-90. PubMed ID: 26786673
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Non-Newtonian Blood Flow Simulation of Diastolic Phase in Bileaflet Mechanical Heart Valve Implanted in a Realistic Aortic Root Containing Coronary Arteries.
    Hanafizadeh P; Mirkhani N; Davoudi MR; Masouminia M; Sadeghy K
    Artif Organs; 2016 Oct; 40(10):E179-E191. PubMed ID: 27739601
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Micro particle image velocimetry measurements of steady diastolic leakage flow in the hinge of a St. Jude Medical® regent™ mechanical heart valve.
    Jun BH; Saikrishnan N; Yoganathan AP
    Ann Biomed Eng; 2014 Mar; 42(3):526-40. PubMed ID: 24085344
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: comparison of experimental and numerical results.
    King MJ; Corden J; David T; Fisher J
    J Biomech; 1996 May; 29(5):609-18. PubMed ID: 8707787
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Numerical investigation on the effect of bileaflet mechanical heart valve's implantation tilting angle and aortic root geometry on intermittent regurgitation and platelet activation.
    Abbas SS; Nasif MS; Al-Waked R; Meor Said MA
    Artif Organs; 2020 Feb; 44(2):E20-E39. PubMed ID: 31378963
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of hinge gap width of a St. Jude medical bileaflet mechanical heart valve on blood damage potential--an in vitro micro particle image velocimetry study.
    Jun BH; Saikrishnan N; Arjunon S; Yun BM; Yoganathan AP
    J Biomech Eng; 2014 Sep; 136(9):091008. PubMed ID: 24976188
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computational Hemodynamic Investigation of Bileaflet and Trileaflet Mechanical Heart Valves.
    Kuan YH; Nguyen VT; Kabinejadian F; Leo HL
    J Heart Valve Dis; 2015 May; 24(3):393-403. PubMed ID: 26901919
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On-X Heart Valve Prosthesis: Numerical Simulation of Hemodynamic Performance in Accelerating Systole.
    Mirkhani N; Davoudi MR; Hanafizadeh P; Javidi D; Saffarian N
    Cardiovasc Eng Technol; 2016 Sep; 7(3):223-37. PubMed ID: 27164902
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves.
    Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-resolution fluid-structure interaction simulations of flow through a bi-leaflet mechanical heart valve in an anatomic aorta.
    Borazjani I; Ge L; Sotiropoulos F
    Ann Biomed Eng; 2010 Feb; 38(2):326-44. PubMed ID: 19806458
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the hinge flow fields of two bileaflet mechanical heart valves under aortic and mitral conditions.
    Simon HA; Leo HL; Carberry J; Yoganathan AP
    Ann Biomed Eng; 2004 Dec; 32(12):1607-17. PubMed ID: 15675674
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of Aortic Wall Deformation with Healthy and Calcified Annulus on Hemodynamic Performance of Implanted On-X Valve.
    Sadipour M; Hanafizadeh P; Sadeghy K; Sattari A
    Cardiovasc Eng Technol; 2020 Apr; 11(2):141-161. PubMed ID: 31912432
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of platelet activation through hinge vs bulk flow in bileaflet mechanical heart valves.
    Hedayat M; Borazjani I
    J Biomech; 2019 Jan; 83():280-290. PubMed ID: 30579576
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.