These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
133 related articles for article (PubMed ID: 25360557)
21. Assessment of cardiac-driven liver movements with filtered harmonic phase image representation, optical flow quantification, and motion amplification. Hahn S; Absil J; Debeir O; Metens T Magn Reson Med; 2019 Apr; 81(4):2788-2798. PubMed ID: 30485536 [TBL] [Abstract][Full Text] [Related]
22. Cardiac material markers from tagged MR images. Kerwin WS; Prince JL Med Image Anal; 1998 Dec; 2(4):339-53. PubMed ID: 10072201 [TBL] [Abstract][Full Text] [Related]
23. Analytic signal phase-based myocardial motion estimation in tagged MRI sequences by a bilinear model and motion compensation. Wang L; Basarab A; Girard PR; Croisille P; Clarysse P; Delachartre P Med Image Anal; 2015 Aug; 24(1):149-162. PubMed ID: 26176412 [TBL] [Abstract][Full Text] [Related]
24. Application of spatial modulation of magnetization (SPAMM) to children: the effect of image resolution on tagging pattern. Haselgrove JC; Fogel MA J Cardiovasc Magn Reson; 2005; 7(2):433-40. PubMed ID: 15881526 [TBL] [Abstract][Full Text] [Related]
26. Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images. O'Dell WG; Moore CC; Hunter WC; Zerhouni EA; McVeigh ER Radiology; 1995 Jun; 195(3):829-35. PubMed ID: 7754016 [TBL] [Abstract][Full Text] [Related]
27. Phase Vector Incompressible Registration Algorithm for Motion Estimation From Tagged Magnetic Resonance Images. Xing F; Woo J; Gomez AD; Pham DL; Bayly PV; Stone M; Prince JL IEEE Trans Med Imaging; 2017 Oct; 36(10):2116-2128. PubMed ID: 28692967 [TBL] [Abstract][Full Text] [Related]
28. Liver stiffness assessment with tagged MRI of cardiac-induced liver motion in cirrhosis patients. Chung S; Kim KE; Park MS; Bhagavatula S; Babb J; Axel L J Magn Reson Imaging; 2014 May; 39(5):1301-7. PubMed ID: 24719241 [TBL] [Abstract][Full Text] [Related]
29. Motion tracking and strain map computation for quasi-static magnetic resonance elastography. Fu YB; Chui CK; Teo CL; Kobayashi E Med Image Comput Comput Assist Interv; 2011; 14(Pt 1):428-35. PubMed ID: 22003646 [TBL] [Abstract][Full Text] [Related]
30. Regenerating MR tagged images using harmonic phase (HARP) methods. Osman NF; Prince JL IEEE Trans Biomed Eng; 2004 Aug; 51(8):1428-33. PubMed ID: 15311829 [TBL] [Abstract][Full Text] [Related]
31. Fast tracking of cardiac motion using 3D-HARP. Pan L; Prince JL; Lima JA; Osman NF IEEE Trans Biomed Eng; 2005 Aug; 52(8):1425-35. PubMed ID: 16119238 [TBL] [Abstract][Full Text] [Related]
32. Accurate harmonic phase tracking of tagged MRI using locally-uniform myocardium displacement constraint. ElDeeb SM; Fahmy AS Med Eng Phys; 2016 Nov; 38(11):1305-1313. PubMed ID: 27595475 [TBL] [Abstract][Full Text] [Related]
34. Shortest path refinement for motion estimation from tagged MR images. Liu X; Prince JL IEEE Trans Med Imaging; 2010 Aug; 29(8):1560-72. PubMed ID: 20304720 [TBL] [Abstract][Full Text] [Related]
35. SIFT-based dense pixel tracking on 0.35 T cine-MR images acquired during image-guided radiation therapy with application to gating optimization. Mazur TR; Fischer-Valuck BW; Wang Y; Yang D; Mutic S; Li HH Med Phys; 2016 Jan; 43(1):279. PubMed ID: 26745921 [TBL] [Abstract][Full Text] [Related]
36. Single shot MR tagging to quantify local tissue deformation during MRI-guided needle interventions: a feasibility study. van den Bosch MR; de Leeuw H; Zwanenburg JJ; Lagendijk JJ; Moerland MA Med Phys; 2011 Oct; 38(10):5321-9. PubMed ID: 21992350 [TBL] [Abstract][Full Text] [Related]
37. Direct pixel to pixel principal strain mapping from tagging MRI using end to end deep convolutional neural network (DeepStrain). Abd-Elmoniem KZ; Yassine IA; Metwalli NS; Hamimi A; Ouwerkerk R; Matta JR; Wessel M; Solomon MA; Elinoff JM; Ghanem AM; Gharib AM Sci Rep; 2021 Nov; 11(1):23021. PubMed ID: 34836988 [TBL] [Abstract][Full Text] [Related]
38. A robust and accurate center-frequency estimation (RACE) algorithm for improving motion estimation performance of SinMod on tagged cardiac MR images without known tagging parameters. Liu H; Wang J; Xu X; Song E; Wang Q; Jin R; Hung CC; Fei B Magn Reson Imaging; 2014 Nov; 32(9):1139-55. PubMed ID: 25087857 [TBL] [Abstract][Full Text] [Related]
39. Deformation analysis of 3D tagged cardiac images using an optical flow method. Xu C; Pilla JJ; Isaac G; Gorman JH; Blom AS; Gorman RC; Ling Z; Dougherty L J Cardiovasc Magn Reson; 2010 Mar; 12(1):19. PubMed ID: 20353600 [TBL] [Abstract][Full Text] [Related]
40. Quantitative assessment of regional myocardial function with MR-tagging in a multi-center study: interobserver and intraobserver agreement of fast strain analysis with Harmonic Phase (HARP) MRI. Castillo E; Osman NF; Rosen BD; El-Shehaby I; Pan L; Jerosch-Herold M; Lai S; Bluemke DA; Lima JA J Cardiovasc Magn Reson; 2005; 7(5):783-91. PubMed ID: 16358393 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]