BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 25367066)

  • 1. Feasibility and efficacy of percutaneously delivered leadless cardiac pacing in an in vivo ovine model.
    Koruth JS; Rippy MK; Khairkhahan A; Ligon DA; Hubbard CA; St Goar F; Lee R; Ribeiro L; Miller M; Dukkipati S; Neuzil P; Reddy VY
    J Cardiovasc Electrophysiol; 2015 Mar; 26(3):322-8. PubMed ID: 25367066
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Combined leadless pacemaker and subcutaneous implantable defibrillator therapy: feasibility, safety, and performance.
    Tjong FV; Brouwer TF; Smeding L; Kooiman KM; de Groot JR; Ligon D; Sanghera R; Schalij MJ; Wilde AA; Knops RE
    Europace; 2016 Nov; 18(11):1740-1747. PubMed ID: 26941338
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Chronic performance of a leadless cardiac pacemaker: 1-year follow-up of the LEADLESS trial.
    Knops RE; Tjong FV; Neuzil P; Sperzel J; Miller MA; Petru J; Simon J; Sediva L; de Groot JR; Dukkipati SR; Koruth JS; Wilde AA; Kautzner J; Reddy VY
    J Am Coll Cardiol; 2015 Apr; 65(15):1497-504. PubMed ID: 25881930
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Percutaneous Implantation of an Entirely Intracardiac Leadless Pacemaker.
    Reddy VY; Exner DV; Cantillon DJ; Doshi R; Bunch TJ; Tomassoni GF; Friedman PA; Estes NA; Ip J; Niazi I; Plunkitt K; Banker R; Porterfield J; Ip JE; Dukkipati SR;
    N Engl J Med; 2015 Sep; 373(12):1125-35. PubMed ID: 26321198
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Permanent leadless cardiac pacing: results of the LEADLESS trial.
    Reddy VY; Knops RE; Sperzel J; Miller MA; Petru J; Simon J; Sediva L; de Groot JR; Tjong FV; Jacobson P; Ostrosff A; Dukkipati SR; Koruth JS; Wilde AA; Kautzner J; Neuzil P
    Circulation; 2014 Apr; 129(14):1466-71. PubMed ID: 24664277
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Initial implantation experience and short-term follow-up results of implanting leadless intracardiac transcatheter pacing system].
    Liang J; Zhao YX; Shi DM; Li YP; Yu Y; Xu XH; Peng PA; Yu M; Wu YF; Sun TN; Zhou YJ
    Zhonghua Xin Xue Guan Bing Za Zhi; 2020 Oct; 48(10):866-870. PubMed ID: 33076625
    [No Abstract]   [Full Text] [Related]  

  • 7. Multiple leadless pacemakers implanted in the right ventricle of swine.
    Chen K; Zheng X; Dai Y; Wang H; Tang Y; Lan T; Zhang J; Tian Y; Zhang B; Zhou X; Bonner M; Zhang S
    Europace; 2016 Nov; 18(11):1748-1752. PubMed ID: 26830889
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the wireless stimulation endocardially for CRT (WiSE-CRT) study.
    Auricchio A; Delnoy PP; Butter C; Brachmann J; Van Erven L; Spitzer S; Moccetti T; Seifert M; Markou T; Laszo K; Regoli F;
    Europace; 2014 May; 16(5):681-8. PubMed ID: 24497573
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long-term outcomes in leadless Micra transcatheter pacemakers with elevated thresholds at implantation: Results from the Micra Transcatheter Pacing System Global Clinical Trial.
    Piccini JP; Stromberg K; Jackson KP; Laager V; Duray GZ; El-Chami M; Ellis CR; Hummel J; Jones DR; Kowal RC; Narasimhan C; Omar R; Ritter P; Roberts PR; Soejima K; Zhang S; Reynolds D;
    Heart Rhythm; 2017 May; 14(5):685-691. PubMed ID: 28111349
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multi-Axes Lead With Tetrahedral Electrode Tip for Cardiac-Implantable Devices: Creative Concept for Pacing and Sensing Technology.
    Bhaskaran A; Liang T; Niri A; Azam MA; Massé S; Asta J; Magtibay K; Lai PFH; Labos C; Ha ACT; Nanthakumar K
    Can J Cardiol; 2021 Nov; 37(11):1808-1817. PubMed ID: 34333028
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Safety and feasibility of a midseptal implantation technique of a leadless pacemaker.
    Hai JJ; Fang J; Tam CC; Wong CK; Un KC; Siu CW; Lau CP; Tse HF
    Heart Rhythm; 2019 Jun; 16(6):896-902. PubMed ID: 30550834
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Leadless Cardiac Pacemakers: Pacing Paradigm Change.
    Neuzil P; Reddy VY
    Curr Cardiol Rep; 2015 Aug; 17(8):68. PubMed ID: 26233700
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Monocentric experience of leadless pacing with focus on challenging cases for conventional pacemaker.
    Garweg C; Ector J; Voros G; Greyling A; Vandenberk B; Foulon S; Willems R
    Acta Cardiol; 2018 Oct; 73(5):459-468. PubMed ID: 29189109
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preclinical safety and electrical performance of novel atrial leadless pacemaker with dual-helix fixation.
    Rashtian M; Banker RS; Neuzil P; Breeman K; Nee P; Badie N; Victorine K; Ligon D; Rippy MK; Eldadah Z; Doshi R; Cantillon DJ; Knops RE
    Heart Rhythm; 2022 May; 19(5):776-781. PubMed ID: 35066177
    [TBL] [Abstract][Full Text] [Related]  

  • 15. First-in-man implantation of leadless ultrasound-based cardiac stimulation pacing system: novel endocardial left ventricular resynchronization therapy in heart failure patients.
    Auricchio A; Delnoy PP; Regoli F; Seifert M; Markou T; Butter C;
    Europace; 2013 Aug; 15(8):1191-7. PubMed ID: 23703364
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Advances in cardiac pacing: beyond the transvenous right ventricular apical lead.
    Kapa S; Bruce CJ; Friedman PA; Asirvatham SJ
    Cardiovasc Ther; 2010 Dec; 28(6):369-79. PubMed ID: 20553288
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The rationale and design of the Micra Transcatheter Pacing Study: safety and efficacy of a novel miniaturized pacemaker.
    Ritter P; Duray GZ; Zhang S; Narasimhan C; Soejima K; Omar R; Laager V; Stromberg K; Williams E; Reynolds D;
    Europace; 2015 May; 17(5):807-13. PubMed ID: 25855677
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Selective-site pacing in paediatric patients: a new application of the Select Secure system.
    Cantù F; De Filippo P; Gabbarini F; Borghi A; Brambilla R; Ferrero P; Comisso J; Marotta T; De Luca A; Gavazzi A
    Europace; 2009 May; 11(5):601-6. PubMed ID: 19269985
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Long-term performance of a novel communicating antitachycardia pacing-enabled leadless pacemaker and subcutaneous implantable cardioverter-defibrillator system: A comprehensive preclinical study.
    Breeman KTN; Swackhamer B; Brisben AJ; Quast ABE; Carter N; Shuros A; Soltis B; Koop BE; Burke MC; Wilde AAM; Tjong FVY; Knops RE
    Heart Rhythm; 2022 May; 19(5):837-846. PubMed ID: 35066181
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcutaneous lead implantation connected to an externalized pacemaker in patients with implantable cardiac defibrillator/pacemaker infection and pacemaker dependency.
    Pecha S; Aydin MA; Yildirim Y; Sill B; Reiter B; Wilke I; Reichenspurner H; Treede H
    Europace; 2013 Aug; 15(8):1205-9. PubMed ID: 23426553
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.