  • 1. In-situ calibration of clinical built-in KAP meters with traceability to a primary standard using a reference KAP meter.
    Malusek A; Helmrot E; Sandborg M; Grindborg JE; Carlsson GA
    Phys Med Biol; 2014 Dec; 59(23):7195-210. PubMed ID: 25369212
    [TBL] [Abstract][Full Text] [Related]  

  • 2. BEAM QUALITY CORRECTION FACTORS FOR KAP METERS FOR LIGHTLY AND HEAVILY FILTERED X-RAY BEAMS.
    Herrnsdorf L; Petersson H
    Radiat Prot Dosimetry; 2016 Jun; 169(1-4):347-52. PubMed ID: 26994096
    [TBL] [Abstract][Full Text] [Related]  

  • 3. ACCURATE KAP METER CALIBRATION AS A PREREQUISITE FOR OPTIMISATION IN PROJECTION RADIOGRAPHY.
    Malusek A; Sandborg M; Carlsson GA
    Radiat Prot Dosimetry; 2016 Jun; 169(1-4):353-9. PubMed ID: 26743261
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of fluoroscopic X-ray beam spectrum on air-kerma measurement accuracy: implications for establishing correction coefficients on interventional fluoroscopes with KAP meters.
    Wunderle KA; Rakowski JT; Dong FF
    J Appl Clin Med Phys; 2016 May; 17(3):467-474. PubMed ID: 27167287
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The energy dependence of the response of a patient dose calibrator.
    Toroi P; Kosunen A
    Phys Med Biol; 2009 May; 54(9):N151-6. PubMed ID: 19351985
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration of reference KAP-meters at SSDL and cross calibration of clinical KAP-meters.
    Hetland PO; Friberg EG; Ovrebø KM; Bjerke HH
    Acta Oncol; 2009; 48(2):289-94. PubMed ID: 18759141
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A tandem calibration method for kerma-area product meters.
    Toroi P; Komppa T; Kosunen A
    Phys Med Biol; 2008 Sep; 53(18):4941-58. PubMed ID: 18711243
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo study of the dependence of the KAP-meter calibration coefficient on beam aperture, x-ray tube voltage and reference plane.
    Malusek A; Larsson JP; Carlsson GA
    Phys Med Biol; 2007 Feb; 52(4):1157-70. PubMed ID: 17264377
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transmission ionization chambers for measurements of air collision kerma integrated over beam area. Factors limiting the accuracy of calibration.
    Larsson JP; Persliden J; Sandborg M; Carlsson GA
    Phys Med Biol; 1996 Nov; 41(11):2381-98. PubMed ID: 8938033
    [TBL] [Abstract][Full Text] [Related]  

  • 10. SURFACE DOSE ESTIMATION BY A KAP METER FOR KILOVOLTAGE X-RAY BEAMS.
    Araki F; Umeno S
    Radiat Prot Dosimetry; 2021 Sep; 195(2):124-131. PubMed ID: 34423373
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ionization chambers for measuring air kerma integrated over beam area. Deviations in calibration values using simplified calibration methods.
    Larsson JP; Persliden J; Carlsson GA
    Phys Med Biol; 1998 Mar; 43(3):599-607. PubMed ID: 9533138
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An international calibration of Kerma-Area Product meters for patient dose optimisation study.
    Jankowski J; Domienik J; Papierz S; Padovani R; Vano E; Faulkner K
    Radiat Prot Dosimetry; 2008; 129(1-3):328-32. PubMed ID: 18319283
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of equalization filters on measurements with kerma-area product meter in a cardiovascular angiography system.
    Ichikawa N; Fukuda A; Hayashi T; Matsubara K
    J Appl Clin Med Phys; 2021 Dec; 22(12):177-185. PubMed ID: 34610646
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Calibration and features of air-kerma length product meters.
    Merimaa K; Tapiovaara M; Kosunen A; Toroi P
    Radiat Prot Dosimetry; 2012 Dec; 152(4):384-92. PubMed ID: 22539532
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Establishing IAEA TRS-457 diagnostic X-ray beam qualities at the Australian primary standard dosimetry laboratory.
    Lee KL; Butler D; Bailey T
    Australas Phys Eng Sci Med; 2017 Dec; 40(4):881-893. PubMed ID: 29159764
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison and uncertainty evaluation of different calibration protocols and ionization chambers for low-energy surface brachytherapy dosimetry.
    Candela-Juan C; Vijande J; García-Martínez T; Niatsetski Y; Nauta G; Schuurman J; Ouhib Z; Ballester F; Perez-Calatayud J
    Med Phys; 2015 Aug; 42(8):4954-64. PubMed ID: 26233221
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
    Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
    Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Evaluation of Radiation Exposure on Mass Screening Examination for Gastric Cancer Using an Air Kerma-area Product Meter].
    Suzuki C; Yamauchi Y; Yamamura D; Takei Y; Suzuki S
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2018 Dec; 74(12):1434-1442. PubMed ID: 30568094
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Review of Kerma-Area Product and total energy incident on patients in radiography, mammography and CT.
    Yao H; Huda W; Mah E; He W
    Radiat Prot Dosimetry; 2015 Feb; 163(2):251-60. PubMed ID: 24821931
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A technique for calibrating a high dose rate ¹⁹²Ir brachytherapy source.
    Fourie OL; Crabtree TG
    Australas Phys Eng Sci Med; 2012 Mar; 35(1):85-92. PubMed ID: 22187355
    [TBL] [Abstract][Full Text] [Related]  