These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

167 related articles for article (PubMed ID: 25370671)

  • 1. CT imaging during microwave ablation: analysis of spatial and temporal tissue contraction.
    Liu D; Brace CL
    Med Phys; 2014 Nov; 41(11):113303. PubMed ID: 25370671
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of tissue deformation during radiofrequency and microwave ablation procedures: Influence of output energy delivery.
    Liu D; Brace CL
    Med Phys; 2019 Sep; 46(9):4127-4134. PubMed ID: 31260115
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Direction of Tissue Contraction after Microwave Ablation: A Comparative Experimental Study in
    Lee J; Rhim H; Lee MW; Kang TW; Song KD; Lee JK
    Korean J Radiol; 2022 Jan; 23(1):42-51. PubMed ID: 34983092
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Numerical simulation of microwave ablation incorporating tissue contraction based on thermal dose.
    Liu D; Brace CL
    Phys Med Biol; 2017 Mar; 62(6):2070-2086. PubMed ID: 28151729
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A dual-slot microwave antenna for more spherical ablation zones: ex vivo and in vivo validation.
    Chiang J; Hynes KA; Bedoya M; Brace CL
    Radiology; 2013 Aug; 268(2):382-9. PubMed ID: 23579048
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Planar strain analysis of liver undergoing microwave thermal ablation using x-ray CT.
    Weiss N; Goldberg SN; Nissenbaum Y; Sosna J; Azhari H
    Med Phys; 2015 Jan; 42(1):372-80. PubMed ID: 25563277
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noninvasive microwave ablation zone radii estimation using x-ray CT image analysis.
    Weiss N; Goldberg SN; Nissenbaum Y; Sosna J; Azhari H
    Med Phys; 2016 Aug; 43(8):4476. PubMed ID: 27487864
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Tissue contraction caused by radiofrequency and microwave ablation: a laboratory study in liver and lung.
    Brace CL; Diaz TA; Hinshaw JL; Lee FT
    J Vasc Interv Radiol; 2010 Aug; 21(8):1280-6. PubMed ID: 20537559
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Predicting the coagulation volume induced by microwave ablation of hepatocellular carcinoma: the role of deposited energy,
    Crocetti L; Amabile C; Scalise P; Tosoratti N; Bozzi E; Rossi P; Cervelli R; Cassarino S; Cioni R
    Int J Hyperthermia; 2021; 38(1):1486-1494. PubMed ID: 34927518
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of the target tissue size on the shape of ex vivo microwave ablation zones.
    Cavagnaro M; Amabile C; Cassarino S; Tosoratti N; Pinto R; Lopresto V
    Int J Hyperthermia; 2015 Feb; 31(1):48-57. PubMed ID: 25677838
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterisation of tissue shrinkage during microwave thermal ablation.
    Farina L; Weiss N; Nissenbaum Y; Cavagnaro M; Lopresto V; Pinto R; Tosoratti N; Amabile C; Cassarino S; Goldberg SN
    Int J Hyperthermia; 2014 Nov; 30(7):419-28. PubMed ID: 25323026
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tissue shrinkage in microwave ablation of liver: an ex vivo predictive model.
    Amabile C; Farina L; Lopresto V; Pinto R; Cassarino S; Tosoratti N; Goldberg SN; Cavagnaro M
    Int J Hyperthermia; 2017 Feb; 33(1):101-109. PubMed ID: 27439333
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiofrequency and microwave ablation in a porcine liver model: non-contrast CT and ultrasound radiologic-pathologic correlation.
    Ziemlewicz TJ; Hinshaw JL; Lubner MG; Knott EA; Willey BJ; Lee FT; Brace CL
    Int J Hyperthermia; 2020; 37(1):799-807. PubMed ID: 32620055
    [No Abstract]   [Full Text] [Related]  

  • 14. A comparison of direct heating during radiofrequency and microwave ablation in ex vivo liver.
    Andreano A; Brace CL
    Cardiovasc Intervent Radiol; 2013 Apr; 36(2):505-11. PubMed ID: 22572764
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Combination Therapies: Quantifying the Effects of Transarterial Embolization on Microwave Ablation Zones.
    Knavel EM; Green CM; Gendron-Fitzpatrick A; Brace CL; Laeseke PF
    J Vasc Interv Radiol; 2018 Jul; 29(7):1050-1056. PubMed ID: 29754849
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sphere-enhanced microwave ablation (sMWA) versus bland microwave ablation (bMWA): technical parameters, specific CT 3D rendering and histopathology.
    Gockner TL; Zelzer S; Mokry T; Gnutzmann D; Bellemann N; Mogler C; Beierfuß A; Köllensperger E; Germann G; Radeleff BA; Stampfl U; Kauczor HU; Pereira PL; Sommer CM
    Cardiovasc Intervent Radiol; 2015 Apr; 38(2):442-52. PubMed ID: 25167958
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Microwave ablation at 10.0 GHz achieves comparable ablation zones to 1.9 GHz in ex vivo bovine liver.
    Luyen H; Gao F; Hagness SC; Behdad N
    IEEE Trans Biomed Eng; 2014 Jun; 61(6):1702-10. PubMed ID: 24845280
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vivo noninvasive three-dimensional (3D) assessment of microwave thermal ablation zone using non-contrast-enhanced x-ray CT.
    Ziv O; Goldberg SN; Nissenbaum Y; Sosna J; Weiss N; Azhari H
    Med Phys; 2020 Oct; 47(10):4721-4734. PubMed ID: 32745257
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microwave ablation energy delivery: influence of power pulsing on ablation results in an ex vivo and in vivo liver model.
    Bedoya M; del Rio AM; Chiang J; Brace CL
    Med Phys; 2014 Dec; 41(12):123301. PubMed ID: 25471983
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Adjuvant Thermal Accelerant Gel Use Increases Microwave Ablation Zone Temperature in Porcine Liver as Measured by MR Thermometry.
    Maxwell AWP; Park WKC; Baird GL; Walsh EG; Dupuy DE
    J Vasc Interv Radiol; 2020 Aug; 31(8):1357-1364. PubMed ID: 32457010
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.