BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

459 related articles for article (PubMed ID: 25376699)

  • 1. Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoon†.
    Aytemir K; Gurses KM; Yalcin MU; Kocyigit D; Dural M; Evranos B; Yorgun H; Ates AH; Sahiner ML; Kaya EB; Oto MA
    Europace; 2015 Mar; 17(3):379-87. PubMed ID: 25376699
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation.
    Martins RP; Hamon D; Césari O; Behaghel A; Behar N; Sellal JM; Daubert JC; Mabo P; Pavin D
    Heart Rhythm; 2014 Mar; 11(3):386-93. PubMed ID: 24389575
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Single 3-minute freeze for second-generation cryoballoon ablation: one-year follow-up after pulmonary vein isolation.
    Ciconte G; de Asmundis C; Sieira J; Conte G; Di Giovanni G; Mugnai G; Saitoh Y; Baltogiannis G; Irfan G; Coutiño-Moreno HE; Hunuk B; Velagić V; Brugada P; Chierchia GB
    Heart Rhythm; 2015 Apr; 12(4):673-80. PubMed ID: 25542427
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: a comparison between the first- and second-generation balloon.
    Casado-Arroyo R; Chierchia GB; Conte G; Levinstein M; Sieira J; Rodriguez-Mañero M; di Giovanni G; Baltogiannis Y; Wauters K; de Asmundis C; Sarkozy A; Brugada P
    Heart Rhythm; 2013 Sep; 10(9):1318-24. PubMed ID: 23891574
    [TBL] [Abstract][Full Text] [Related]  

  • 5. One-year follow-up after second-generation cryoballoon ablation for atrial fibrillation in a large cohort of patients: a single-centre experience.
    Irfan G; de Asmundis C; Mugnai G; Poelaert J; Verborgh C; Umbrain V; Beckers S; Hacioglu E; Hunuk B; Velagic V; Stroker E; Brugada P; Chierchia GB
    Europace; 2016 Jul; 18(7):987-93. PubMed ID: 26705562
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Circumferential pulmonary vein isolation as index procedure for persistent atrial fibrillation: a comparison between radiofrequency catheter ablation and second-generation cryoballoon ablation.
    Ciconte G; Baltogiannis G; de Asmundis C; Sieira J; Conte G; Di Giovanni G; Saitoh Y; Irfan G; Mugnai G; Hunuk B; Chierchia GB; Brugada P
    Europace; 2015 Apr; 17(4):559-65. PubMed ID: 25582875
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after ablation using the second-generation cryoballoon.
    Ciconte G; Ottaviano L; de Asmundis C; Baltogiannis G; Conte G; Sieira J; Di Giovanni G; Saitoh Y; Irfan G; Mugnai G; Storti C; Montenero AS; Chierchia GB; Brugada P
    Heart Rhythm; 2015 Jan; 12(1):60-6. PubMed ID: 25281891
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cryoballoon versus Radiofrequency Catheter Ablation in Atrial Fibrillation: A Meta-Analysis.
    Cardoso R; Mendirichaga R; Fernandes G; Healy C; Lambrakos LK; Viles-Gonzalez JF; Goldberger JJ; Mitrani RD
    J Cardiovasc Electrophysiol; 2016 Oct; 27(10):1151-1159. PubMed ID: 27422848
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison between radiofrequency with contact force-sensing and second-generation cryoballoon for paroxysmal atrial fibrillation catheter ablation: a multicentre European evaluation.
    Squara F; Zhao A; Marijon E; Latcu DG; Providencia R; Di Giovanni G; Jauvert G; Jourda F; Chierchia GB; De Asmundis C; Ciconte G; Alonso C; Grimard C; Boveda S; Cauchemez B; Saoudi N; Brugada P; Albenque JP; Thomas O
    Europace; 2015 May; 17(5):718-24. PubMed ID: 25840289
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contact-force guided radiofrequency vs. second-generation balloon cryotherapy for pulmonary vein isolation in patients with paroxysmal atrial fibrillation-a prospective evaluation.
    Jourda F; Providencia R; Marijon E; Bouzeman A; Hireche H; Khoueiry Z; Cardin C; Combes N; Combes S; Boveda S; Albenque JP
    Europace; 2015 Feb; 17(2):225-31. PubMed ID: 25186456
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Long-term comparison of cryoballoon and radiofrequency ablation of paroxysmal atrial fibrillation: a propensity score matched analysis.
    Knecht S; Sticherling C; von Felten S; Conen D; Schaer B; Ammann P; Altmann D; Osswald S; Kühne M
    Int J Cardiol; 2014 Oct; 176(3):645-50. PubMed ID: 25149399
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term outcomes of cryoballoon pulmonary vein isolation for paroxysmal and persistent atrial fibrillation in Chinese patients.
    Chan NY; Choy CC; Yuen HC; Chow HF; Fong HF
    J Interv Card Electrophysiol; 2020 Apr; 57(3):425-434. PubMed ID: 31016428
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up.
    Chierchia GB; Di Giovanni G; Ciconte G; de Asmundis C; Conte G; Sieira-Moret J; Rodriguez-Mañero M; Casado R; Baltogiannis G; Namdar M; Saitoh Y; Paparella G; Mugnai G; Brugada P
    Europace; 2014 May; 16(5):639-44. PubMed ID: 24478116
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pulmonary Vein Isolation Using a Second-Generation Cryoballoon in Patients With Paroxysmal Atrial Fibrillation: One-Year Outcome Using a Single Big-Balloon 3-Minute Freeze Technique.
    Miyazaki S; Hachiya H; Nakamura H; Taniguchi H; Takagi T; Hirao K; Iesaka Y
    J Cardiovasc Electrophysiol; 2016 Dec; 27(12):1375-1380. PubMed ID: 27534931
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The incidence of phrenic nerve injury during pulmonary vein isolation using the second-generation 28 mm cryoballoon.
    Metzner A; Rausch P; Lemes C; Reissmann B; Bardyszewski A; Tilz R; Rillig A; Mathew S; Deiss S; Kamioka M; Toennis T; Lin T; Ouyang F; Kuck KH; Wissner E
    J Cardiovasc Electrophysiol; 2014 May; 25(5):466-470. PubMed ID: 24400647
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safety and efficacy of persistent atrial fibrillation ablation using the second-generation cryoballoon.
    Yalin K; Abdin A; Lyan E; Sawan N; Liosis S; Elsner C; Jobs A; Brüggemann B; Koester J; Eitel I; Eitel C; Tilz RR
    Clin Res Cardiol; 2018 Jul; 107(7):570-577. PubMed ID: 29492703
    [TBL] [Abstract][Full Text] [Related]  

  • 17. One-year follow-up after single procedure Cryoballoon ablation: a comparison between the first and second generation balloon.
    Giovanni GD; Wauters K; Chierchia GB; Sieira J; Levinstein M; Conte G; DE Asmundis C; Baltogiannis G; Saitoh Y; Ciconte G; Julia J; Mugnai G; Irfan G; Brugada P
    J Cardiovasc Electrophysiol; 2014 Aug; 25(8):834-839. PubMed ID: 24641307
    [TBL] [Abstract][Full Text] [Related]  

  • 18. One-year clinical success of a 'no-bonus' freeze protocol using the second-generation 28 mm cryoballoon for pulmonary vein isolation.
    Wissner E; Heeger CH; Grahn H; Reissmann B; Wohlmuth P; Lemes C; Rausch P; Mathew S; Rillig A; Deiss S; Maurer T; Lin T; Tilz RR; Ouyang F; Kuck KH; Metzner A
    Europace; 2015 Aug; 17(8):1236-40. PubMed ID: 25868468
    [TBL] [Abstract][Full Text] [Related]  

  • 19. One-year clinical outcome after pulmonary vein isolation in persistent atrial fibrillation using the second-generation 28 mm cryoballoon: a retrospective analysis.
    Lemes C; Wissner E; Lin T; Mathew S; Deiss S; Rillig A; Heeger C; Wohlmuth P; Reissmann B; Tilz R; Ouyang F; Kuck KH; Metzner A
    Europace; 2016 Feb; 18(2):201-5. PubMed ID: 25995389
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Second-Generation Cryoballoon Ablation in the Setting of Lone Paroxysmal Atrial Fibrillation: Single Procedural Outcome at 12 Months.
    DE Regibus V; Mugnai G; Moran D; Hünük B; Ströker E; Hacioglu E; Ruggiero D; Coutiño-Moreno HE; Takarada K; Brugada P; DE Asmundis C; Chierchia GB
    J Cardiovasc Electrophysiol; 2016 Jun; 27(6):677-82. PubMed ID: 27026284
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.