168 related articles for article (PubMed ID: 25377182)
1. A comparison of fibrinogen measurement using TEG(®) functional fibrinogen and Clauss in cardiac surgery patients.
Agarwal S; Johnson RI; Shaw M
Int J Lab Hematol; 2015 Aug; 37(4):459-65. PubMed ID: 25377182
[TBL] [Abstract][Full Text] [Related]
2. A comparative study of fibrinogen measurement using TEG® functional fibrinogen and Clauss in adolescents undergoing scoliosis surgery.
Chen W; Hu A; Chen Q; Zhang Y; Yu X; Huang Y
Int J Lab Hematol; 2020 Aug; 42(4):380-386. PubMed ID: 32222095
[TBL] [Abstract][Full Text] [Related]
3. Performance of functional fibrinogen thromboelastography in children undergoing congenital heart surgery.
Gautam NK; Cai C; Pawelek O; Rafique MB; Cattano D; Pivalizza EG
Paediatr Anaesth; 2017 Feb; 27(2):181-189. PubMed ID: 27901294
[TBL] [Abstract][Full Text] [Related]
4. FIBTEM PLUS provides an improved thromboelastometry test for measurement of fibrin-based clot quality in cardiac surgery patients.
Solomon C; Baryshnikova E; Schlimp CJ; Schöchl H; Asmis LM; Ranucci M
Anesth Analg; 2013 Nov; 117(5):1054-62. PubMed ID: 24108255
[TBL] [Abstract][Full Text] [Related]
5. Comparison of Thrombelastography-Derived Fibrinogen Values at Rewarming and Following Cardiopulmonary Bypass in Cardiac Surgery Patients.
Fabbro M; Gutsche JT; Miano TA; Augoustides JG; Patel PA
Anesth Analg; 2016 Sep; 123(3):570-7. PubMed ID: 27541720
[TBL] [Abstract][Full Text] [Related]
6. Functional fibrinogen assay indicates that fibrinogen is critical in correcting abnormal clot strength following trauma.
Harr JN; Moore EE; Ghasabyan A; Chin TL; Sauaia A; Banerjee A; Silliman CC
Shock; 2013 Jan; 39(1):45-9. PubMed ID: 23247121
[TBL] [Abstract][Full Text] [Related]
7. Comparison of Thromboelastography Devices TEG
Emani S; Emani VS; Diallo FB; Dutta P; Matte GS; Nathan M; Ibla JC; Emani SM
J Extra Corpor Technol; 2022 Mar; 54(1):42-49. PubMed ID: 36380826
[TBL] [Abstract][Full Text] [Related]
8. Clinical applicability of rapid thrombelastography and functional fibrinogen thrombelastography to adult liver transplantation.
Yang Lu S; Tanaka KA; Abuelkasem E; Planinsic RM; Sakai T
Liver Transpl; 2014 Sep; 20(9):1097-105. PubMed ID: 24889921
[TBL] [Abstract][Full Text] [Related]
9. Validation of viscoelastic coagulation tests during cardiopulmonary bypass.
Ortmann E; Rubino A; Altemimi B; Collier T; Besser MW; Klein AA
J Thromb Haemost; 2015 Jul; 13(7):1207-16. PubMed ID: 25903995
[TBL] [Abstract][Full Text] [Related]
10. Noncitrated whole blood is optimal for evaluation of postinjury coagulopathy with point-of-care rapid thrombelastography.
Kashuk JL; Moore EE; Le T; Lawrence J; Pezold M; Johnson JL; Cothren CC; Biffl WL; Barnett C; Sabel A
J Surg Res; 2009 Sep; 156(1):133-8. PubMed ID: 19577246
[TBL] [Abstract][Full Text] [Related]
11. Kaolin-activated thromboelastography and standard coagulation assays in cyanotic and acyanotic infants undergoing complex cardiac surgery: a prospective cohort study.
Rizza A; Ricci Z; Pezzella C; Favia I; Di Felice G; Ranucci M; Cogo P
Paediatr Anaesth; 2017 Feb; 27(2):170-180. PubMed ID: 27935164
[TBL] [Abstract][Full Text] [Related]
12. Point-of-Care Viscoelastic Hemostatic Assays in Cardiac Surgery Patients: Comparison of Thromboelastography 6S, Thromboelastometry Sigma, and Quantra.
Demailly Z; Wurtz V; Barbay V; Surlemont E; Scherrer V; Compère V; Billoir P; Clavier T; Besnier E
J Cardiothorac Vasc Anesth; 2023 Jun; 37(6):948-955. PubMed ID: 36931905
[TBL] [Abstract][Full Text] [Related]
13. Functional fibrinogen (FLEV-TEG) versus the Clauss method in an obstetric population: a comparative study.
Spasiano A; Matellon C; Orso D; Brussa A; Cafagna M; Marangone A; Dogareschi T; Bove T; Giacomello R; Fontana D; Vetrugno L; Della Rocca G
BMC Anesthesiol; 2019 Jun; 19(1):90. PubMed ID: 31153366
[TBL] [Abstract][Full Text] [Related]
14. Are the point-of-care diagnostics MULTIPLATE and ROTEM valid in the setting of high concentrations of heparin and its reversal with protamine?
Gertler R; Wiesner G; Tassani-Prell P; Braun SL; Martin K
J Cardiothorac Vasc Anesth; 2011 Dec; 25(6):981-6. PubMed ID: 21315618
[TBL] [Abstract][Full Text] [Related]
15. Fibrinogen and platelet contributions to clot formation: implications for trauma resuscitation and thromboprophylaxis.
Kornblith LZ; Kutcher ME; Redick BJ; Calfee CS; Vilardi RF; Cohen MJ
J Trauma Acute Care Surg; 2014 Feb; 76(2):255-6; discussion 262-3. PubMed ID: 24458031
[TBL] [Abstract][Full Text] [Related]
16. Thromboelastography (TEG®) compared to conventional coagulation tests in surgical patients--a laboratory evaluation.
Ågren A; Wikman AT; Holmström M; Östlund A; Edgren G
Scand J Clin Lab Invest; 2013 Apr; 73(3):214-20. PubMed ID: 23402666
[TBL] [Abstract][Full Text] [Related]
17. Validity of Thromboelastometry for Rapid Assessment of Fibrinogen Levels in Heparinized Samples During Cardiac Surgery: A Retrospective, Single-center, Observational Study.
Mace H; Lightfoot N; McCluskey S; Selby R; Roy D; Timoumi T; Karkouti K
J Cardiothorac Vasc Anesth; 2016 Jan; 30(1):90-5. PubMed ID: 26296822
[TBL] [Abstract][Full Text] [Related]
18. Comparison of whole blood fibrin-based clot tests in thrombelastography and thromboelastometry.
Solomon C; Sørensen B; Hochleitner G; Kashuk J; Ranucci M; Schöchl H
Anesth Analg; 2012 Apr; 114(4):721-30. PubMed ID: 22314689
[TBL] [Abstract][Full Text] [Related]
19. Heparinase thromboelastography compared with activated coagulation time for protamine titration after cardiopulmonary bypass.
Levin AI; Heine AM; Coetzee JF; Coetzee A
J Cardiothorac Vasc Anesth; 2014 Apr; 28(2):224-9. PubMed ID: 24461364
[TBL] [Abstract][Full Text] [Related]
20. The relationship among thromboelastography, hemostatic variables, and bleeding after cardiopulmonary bypass surgery in children.
Moganasundram S; Hunt BJ; Sykes K; Holton F; Parmar K; Durward A; Murdoch IA; Austin C; Anderson D; Tibby SM
Anesth Analg; 2010 Apr; 110(4):995-1002. PubMed ID: 20142345
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]