234 related articles for article (PubMed ID: 25390281)
1. The effectiveness of oxygen delivery and reliability of carbon dioxide waveforms: a crossover comparison of 4 nasal cannulae.
Ebert TJ; Novalija J; Uhrich TD; Barney JA
Anesth Analg; 2015 Feb; 120(2):342-8. PubMed ID: 25390281
[TBL] [Abstract][Full Text] [Related]
2. Modified nasal cannula for simultaneous oxygen delivery and end-tidal CO2 monitoring during spontaneous breathing.
Yanagidate F; Dohi S
Eur J Anaesthesiol; 2006 Mar; 23(3):257-60. PubMed ID: 16430798
[TBL] [Abstract][Full Text] [Related]
3. The effect of inhalation of different mixtures of O2 and CO2 on ocular fundus pulsations.
Schmetterer L; Lexer F; Findl O; Graselli U; Eichler HG; Wolzt M
Exp Eye Res; 1996 Oct; 63(4):351-5. PubMed ID: 8944542
[TBL] [Abstract][Full Text] [Related]
4. Noninvasive carbon dioxide monitoring in a porcine model of acute lung injury due to smoke inhalation and burns.
Belenkiy S; Ivey KM; Batchinsky AI; Langer T; Necsoiu C; Baker W; Salinas J; Cancio LC
Shock; 2013 Jun; 39(6):495-500. PubMed ID: 23572088
[TBL] [Abstract][Full Text] [Related]
5. [The behavior of arterial and mixed venous oxygen and carbon dioxide partial pressure and the pH value during and following intubation apnoea. Studies on the occurrence of the Christiansen-Douglas-Haldane effect].
Merkelbach D; Brandt L; Mertzlufft F
Anaesthesist; 1993 Oct; 42(10):691-701. PubMed ID: 8250203
[TBL] [Abstract][Full Text] [Related]
6. Accuracy of end-tidal CO2 measurement through the nose and pharynx in nonintubated patients during digital subtraction cerebral angiography.
Zhang C; Wang M; Wang R; Wang W
J Neurosurg Anesthesiol; 2013 Apr; 25(2):191-6. PubMed ID: 23269088
[TBL] [Abstract][Full Text] [Related]
7. Relationship between arterial carbon dioxide and end-tidal carbon dioxide when a nasal sampling port is used.
McNulty SE; Roy J; Torjman M; Seltzer JL
J Clin Monit; 1990 Apr; 6(2):93-8. PubMed ID: 2112592
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of an oxygen mask-based capnometry device in subjects extubated after abdominal surgery.
Takaki S; Mihara T; Mizutani K; Yamaguchi O; Goto T
Respir Care; 2015 May; 60(5):705-10. PubMed ID: 25587160
[TBL] [Abstract][Full Text] [Related]
9. Comparing Nasal End-Tidal Carbon Dioxide Measurement Variation and Agreement While Delivering Pulsed and Continuous Flow Oxygen in Volunteers and Patients.
Burk KM; Sakata DJ; Kuck K; Orr JA
Anesth Analg; 2020 Mar; 130(3):715-724. PubMed ID: 30633057
[TBL] [Abstract][Full Text] [Related]
10. [Usefulness of NODSS (nasal/oral discriminate sampling system) in end-tidal carbon dioxide gas monitoring].
Imai K; Chinzei M; Oguchi K; Tamai H; Sato Y; Umeyama T; Tagami M; Hanaoka K
Masui; 1996 Jul; 45(7):837-41. PubMed ID: 8741473
[TBL] [Abstract][Full Text] [Related]
11. Airway insufflation: physiologic effects on acute and chronic gas exchange in humans.
Bergofsky EH; Hurewitz AN
Am Rev Respir Dis; 1989 Oct; 140(4):885-90. PubMed ID: 2508522
[TBL] [Abstract][Full Text] [Related]
12. Utility of Prehospital Quantitative End Tidal CO2?
Cooper CJ; Kraatz JJ; Kubiak DS; Kessel JW; Barnes SL
Prehosp Disaster Med; 2013 Apr; 28(2):87-93. PubMed ID: 23343590
[TBL] [Abstract][Full Text] [Related]
13. A clinical determination of optimal fresh gas flow in a baby EAR circuit.
Theerapongpakdee S; Phanpanusit T; Horatanaruang D; Bunsangjaroen P; Limpkulwathanaporn P; Thananun M; Nonlhaopol D
J Med Assoc Thai; 2009 May; 92(5):667-71. PubMed ID: 19459529
[TBL] [Abstract][Full Text] [Related]
14. [Nasal catheters versus Hudson face mask in oxygen therapy].
Lund J; Holm-Knudsen RJ; Nielsen J; Føge Jensen PB
Ugeskr Laeger; 1996 Jul; 158(28):4077-9. PubMed ID: 8701523
[TBL] [Abstract][Full Text] [Related]
15. [Usefulness of a new nasal cannula with an end-tidal carbon dioxide measuring port].
Nishiyama T; Hanaoka K
Masui; 2003 Apr; 52(4):424-6. PubMed ID: 12728498
[TBL] [Abstract][Full Text] [Related]
16. End tidal carbon dioxide monitoring in spontaneously breathing, nonintubated patients. A clinical comparison between conventional sidestream and microstream capnometers.
Casati A; Gallioli G; Passaretta R; Scandroglio M; Bignami E; Torri G
Minerva Anestesiol; 2001 Apr; 67(4):161-4. PubMed ID: 11376503
[TBL] [Abstract][Full Text] [Related]
17. [Air embolism in the sitting position. Oxygen/nitrogen versus oxygen/laughing gas].
Knüttgen D; Stölzle U; Köning W; Müller MR; Doehn M
Anaesthesist; 1989 Sep; 38(9):490-7. PubMed ID: 2686489
[TBL] [Abstract][Full Text] [Related]
18. Cardiovascular effects of hyperbaric oxygen with and without addition of carbon dioxide.
Bergo GW; Tyssebotn I
Eur J Appl Physiol Occup Physiol; 1999 Sep; 80(4):264-75. PubMed ID: 10483795
[TBL] [Abstract][Full Text] [Related]
19. The effect of increased apparatus dead space and tidal volumes on carbon dioxide elimination and oxygen saturations in a low-flow anesthesia system.
Enekvist BJ; Luttropp HH; Johansson A
J Clin Anesth; 2008 May; 20(3):170-4. PubMed ID: 18502358
[TBL] [Abstract][Full Text] [Related]
20. Dependence of BOLD signal fluctuation on arterial blood CO2 and O2: Implication for resting-state functional connectivity.
Nasrallah FA; Yeow LY; Biswal B; Chuang KH
Neuroimage; 2015 Aug; 117():29-39. PubMed ID: 26003858
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]