207 related articles for article (PubMed ID: 25391865)
1. [Reduced-dose mode with low-voltage and low contrast agent in coronary artery CT angiography-a preliminary study].
Lu L; Xu K; Wang C; Li S; Xie L; Wang J; Li C; Rong Y
Zhonghua Yi Xue Za Zhi; 2014 Aug; 94(29):2251-5. PubMed ID: 25391865
[TBL] [Abstract][Full Text] [Related]
2. Application of Low Tube Voltage, Low-concentration Contrast Agent Using a 320-row CT in Coronary CT Angiography: Evaluation of Image Quality, Radiation Dose and Iodine Intake.
Pan YY; Zhou SC; Wang YJ; Li Q; Zhu TT; Liu CX; Guan HX
Curr Med Sci; 2020 Feb; 40(1):178-183. PubMed ID: 32166681
[TBL] [Abstract][Full Text] [Related]
3. [Study of low radiation exposure dose and low contrast medium dose in coronary CT angiography with High-pitch spiral acquisition mode of dual source CT].
Dai Y; Guo L; Dai Q; Liu Y; Ma X
Zhonghua Yi Xue Za Zhi; 2014 Aug; 94(29):2247-50. PubMed ID: 25391864
[TBL] [Abstract][Full Text] [Related]
4. [The application of setting tube voltage and iodine delivery rate in weight-grouped for reducing the radiation and contrast medium dose in coronary CT angiography].
Zhang Y; Wu JX; Wang Y; Yuan HS
Zhonghua Yi Xue Za Zhi; 2024 Mar; 104(10):751-757. PubMed ID: 38462355
[No Abstract] [Full Text] [Related]
5. A prospective evaluation of contrast and radiation dose and image quality in cardiac CT in children with complex congenital heart disease using low-concentration iodinated contrast agent and low tube voltage and current.
Hou QR; Gao W; Sun AM; Wang Q; Qiu HS; Wang F; Hu LW; Li JY; Zhong YM
Br J Radiol; 2017 Feb; 90(1070):20160669. PubMed ID: 27925466
[TBL] [Abstract][Full Text] [Related]
6. Effect of reduced x-ray tube voltage, low iodine concentration contrast medium, and sinogram-affirmed iterative reconstruction on image quality and radiation dose at coronary CT angiography: results of the prospective multicenter REALISE trial.
Yin WH; Lu B; Gao JB; Li PL; Sun K; Wu ZF; Yang WJ; Zhang XQ; Zheng MW; McQuiston AD; Meinel FG; Schoepf UJ
J Cardiovasc Comput Tomogr; 2015; 9(3):215-24. PubMed ID: 25843243
[TBL] [Abstract][Full Text] [Related]
7. Using the K-edge to improve contrast conspicuity and to lower radiation dose with a 16-MDCT: a phantom and human study.
Kalva SP; Sahani DV; Hahn PF; Saini S
J Comput Assist Tomogr; 2006; 30(3):391-7. PubMed ID: 16778612
[TBL] [Abstract][Full Text] [Related]
8. Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: a comparative study.
Cao JX; Wang YM; Lu JG; Zhang Y; Wang P; Yang C
Eur J Radiol; 2014 Feb; 83(2):309-14. PubMed ID: 24315475
[TBL] [Abstract][Full Text] [Related]
9. A prospective evaluation of the contrast, radiation dose and image quality of contrast-enhanced CT scans of paediatric abdomens using a low-concentration iodinated contrast agent and low tube voltage combined with 70% ASIR algorithm.
Wang X; Zhong Y; Hu L; Xue L; Shi M; Qiu H; Li J
Int J Clin Pract; 2016 Sep; 70 Suppl 9B():B16-21. PubMed ID: 27577509
[TBL] [Abstract][Full Text] [Related]
10. [Preliminary study of improved quality of computed tomographic angiography on tumor blood supply arteries of gastrointestinal tract malignant tumors with low tube voltage and low concentration contrast medium].
Li Y; Liu A; Cao H; Tian S; Liu J; Wang H; Zhang T; Liu Y; Pu R; Liu X
Zhonghua Yi Xue Za Zhi; 2015 Mar; 95(11):819-22. PubMed ID: 26080912
[TBL] [Abstract][Full Text] [Related]
11. Application of low tube voltage coronary CT angiography with low-dose iodine contrast agent in patients with a BMI of 26-30 kg/m2.
Sun G; Hou YB; Zhang B; Yu L; Li SX; Tan LL; Chen DJ
Clin Radiol; 2015 Feb; 70(2):138-45. PubMed ID: 25468636
[TBL] [Abstract][Full Text] [Related]
12. [Application of iodine contrast agent optimization protocol with fixed injection time in triple-rule-out CT examination of chest pain].
Hua L; Zhang J; Zhang S; Zhang C; Wang Z; Zhang Y
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2019 May; 31(5):582-587. PubMed ID: 31198144
[TBL] [Abstract][Full Text] [Related]
13. Coronary Computed Tomographic Angiography at Low Concentration of Contrast Agent and Low Tube Voltage in Patients with Obesity:: A Feasibility Study.
Pan YN; Li AJ; Chen XM; Wang J; Ren DW; Huang QL
Acad Radiol; 2016 Apr; 23(4):438-45. PubMed ID: 26872868
[TBL] [Abstract][Full Text] [Related]
14. Application of 80-kVp tube voltage, low-concentration contrast agent and iterative reconstruction in coronary CT angiography: evaluation of image quality and radiation dose.
Wu Q; Wang Y; Kai H; Wang T; Tang X; Wang X; Pan C
Int J Clin Pract; 2016 Sep; 70 Suppl 9B():B50-5. PubMed ID: 27577515
[TBL] [Abstract][Full Text] [Related]
15. Imaging quality evaluation of low tube voltage coronary CT angiography using low concentration contrast medium.
Zhang C; Yu Y; Zhang Z; Wang Q; Zheng L; Feng Y; Zhou Z; Zhang G; Li K
PLoS One; 2015; 10(3):e0120539. PubMed ID: 25811785
[TBL] [Abstract][Full Text] [Related]
16. Low contrast and radiation dose coronary CT angiography using a 320-row system and a refined contrast injection and timing method.
Oda S; Utsunomiya D; Yuki H; Kai N; Hatemura M; Funama Y; Kidoh M; Yoshida M; Namimoto T; Yamashita Y
J Cardiovasc Comput Tomogr; 2015; 9(1):19-27. PubMed ID: 25677790
[TBL] [Abstract][Full Text] [Related]
17. Low-concentration contrast medium for 128-slice dual-source CT coronary angiography at a very low radiation dose using prospectively ECG-triggered high-pitch spiral acquisition.
Zheng M; Wu Y; Wei M; Liu Y; Zhao H; Li J
Acad Radiol; 2015 Feb; 22(2):195-202. PubMed ID: 25457735
[TBL] [Abstract][Full Text] [Related]
18. [Value of CT Angiography Using Low Tube Voltage and Low Contrast Combined with Iterative Model Reconstruction in Patients with Coronary Artery Bypass Grafts].
Luo CC; Tang T; Li T; Yang L; Li JF; Zhang XH; Zhang J
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2018 Dec; 40(6):744-749. PubMed ID: 30606383
[TBL] [Abstract][Full Text] [Related]
19. Comparing feasibility of different tube voltages and different concentrations of contrast medium in coronary CT angiography of overweight patients.
Liu ZC; Zhao S; Ma ZP; Zhang TL; Zhao YX
J Xray Sci Technol; 2022; 30(6):1261-1272. PubMed ID: 36214032
[TBL] [Abstract][Full Text] [Related]
20. Cerebral computed tomography angiography using a low tube voltage (80 kVp) and a moderate concentration of iodine contrast material: a quantitative and qualitative comparison with conventional computed tomography angiography.
Cho ES; Chung TS; Oh DK; Choi HS; Suh SH; Lee HK; Lee KH
Invest Radiol; 2012 Feb; 47(2):142-7. PubMed ID: 22104960
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]