These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
195 related articles for article (PubMed ID: 25392547)
1. Minimally invasive proximal interphalangeal joint arthrodesis using a locking compression plate and tissue engineering in horses: a pilot study. Seo JP; Yamaga T; Tsuzuki N; Yamada K; Haneda S; Furuoka H; Tabata Y; Sasaki N Can Vet J; 2014 Nov; 55(11):1050-6. PubMed ID: 25392547 [TBL] [Abstract][Full Text] [Related]
2. In vitro biomechanical comparison of a 4.5 mm narrow locking compression plate construct versus a 4.5 mm limited contact dynamic compression plate construct for arthrodesis of the equine proximal interphalangeal joint. Ahern BJ; Showalter BL; Elliott DM; Richardson DW; Getman LM Vet Surg; 2013 Apr; 42(3):335-9. PubMed ID: 23445267 [TBL] [Abstract][Full Text] [Related]
3. In vitro biomechanical comparison of a 5-hole 4.5 mm locking compression plate and 5-hole 4.5 mm dynamic compression plate for equine proximal interphalangeal joint arthrodesis. Seo JP; Yamaga T; Tsuzuki N; Yamada K; Haneda S; Furuoka H; Sasaki N Vet Surg; 2014 Jul; 43(5):606-11. PubMed ID: 24512440 [TBL] [Abstract][Full Text] [Related]
4. Proximal interphalangeal joint arthrodesis using a combination plate-screw technique in 53 horses (1994-2003). Knox PM; Watkins JP Equine Vet J; 2006 Nov; 38(6):538-42. PubMed ID: 17124844 [TBL] [Abstract][Full Text] [Related]
5. Retrospective analysis of factors associated with outcome of proximal interphalangeal joint arthrodesis in 82 horses including Warmblood and Thoroughbred sport horses and Quarter Horses (1992-2014). Herthel TD; Rick MC; Judy CE; Cohen ND; Herthel DJ Equine Vet J; 2016 Sep; 48(5):557-64. PubMed ID: 26289294 [TBL] [Abstract][Full Text] [Related]
6. A mechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial locking compression plate and two abaxial transarticular cortical screws versus an axial dynamic compression plate and two abaxial transarticular cortical screws. Sod GA; Riggs LM; Mitchell CF; Martin GS Vet Surg; 2011 Jul; 40(5):571-8. PubMed ID: 21521241 [TBL] [Abstract][Full Text] [Related]
7. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 3-hole 4.5 mm locking compression plate and 3-hole 4.5 mm narrow dynamic compression plate, with two transarticular 5.5 mm cortex screws. Zoppa AL; Santoni B; Puttlitz CM; Cochran K; Hendrickson DA Vet Surg; 2011 Feb; 40(2):253-9. PubMed ID: 21244444 [TBL] [Abstract][Full Text] [Related]
8. Clinical use of the locking compression plate (LCP) in horses: a retrospective study of 31 cases (2004-2006). Levine DG; Richardson DW Equine Vet J; 2007 Sep; 39(5):401-6. PubMed ID: 17910263 [TBL] [Abstract][Full Text] [Related]
9. Comparison of limited-contact dynamic compression plate and locking compression plate constructs for proximal interphalangeal joint arthrodesis in the horse. Rocconi RA; Carmalt JL; Sampson SN; Elder SH; Gilbert EE Can Vet J; 2015 Jun; 56(6):615-9. PubMed ID: 26028685 [TBL] [Abstract][Full Text] [Related]
10. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion. Sod GA; Riggs LM; Mitchell CF; Hubert JD; Martin GS Vet Surg; 2010 Jan; 39(1):83-90. PubMed ID: 20210950 [TBL] [Abstract][Full Text] [Related]
11. Use of a locking compression plate for equine proximal interphalangeal joint arthrodesis: 29 cases (2008-2014). Sakai RR; Goodrich LR; Katzman SA; Moorman VJ; Leise BS; Kawcak CE; Galuppo LD J Am Vet Med Assoc; 2018 Dec; 253(11):1460-1466. PubMed ID: 30451612 [TBL] [Abstract][Full Text] [Related]
12. Proximal interphalangeal arthrodesis in 22 horses. Schaer TP; Bramlage LR; Embertson RM; Hance S Equine Vet J; 2001 Jul; 33(4):360-5. PubMed ID: 11469768 [TBL] [Abstract][Full Text] [Related]
13. Comparison of a 3-hole 4.5-mm Dynamic Compression Plate and a 7-hole 5.5-mm Y Locking Compression Plate for Arthrodesis of the Proximal Interphalangeal Joint in Horses-an Ex Vivo Biomechanical Study. Latorre CAS; de Souza AF; Ramos PAR; Nóbrega FS; van de Graaf GMM; Pereira CAM; Ferrigno CRA; Hendrickson DA; De Zoppa ALDV J Equine Vet Sci; 2020 Nov; 94():103252. PubMed ID: 33077103 [TBL] [Abstract][Full Text] [Related]
14. Does the proximal screw type affect stress and strain in pastern arthrodesis with locking plate in horses? de Souza AF; Pereira CAM; Fürst A; Kümmerle JM; De Zoppa ALDV Res Vet Sci; 2024 Oct; 178():105378. PubMed ID: 39137606 [TBL] [Abstract][Full Text] [Related]
15. Area of cartilage accessible to curettage for subsequent arthrodesis of the equine proximal interphalangeal joint. Comparison of conventional and collateral ligament sparing approaches. Kuemmerle JM; Berchtold S Vet Comp Orthop Traumatol; 2013; 26(6):489-92. PubMed ID: 24008595 [TBL] [Abstract][Full Text] [Related]
16. Arthrodesis of the proximal interphalangeal joint in the horse: a surgical treatment for high ringbone. Schneider JE; Carnine BL; Guffy MM J Am Vet Med Assoc; 1978 Nov; 173(10):1364-9. PubMed ID: 365842 [No Abstract] [Full Text] [Related]
17. A limited surgical approach for pastern arthrodesis in horses with severe osteoarthritis. Jones P; Delco M; Beard W; Lillich JD; Desormaux A Vet Comp Orthop Traumatol; 2009; 22(4):303-8. PubMed ID: 19597626 [TBL] [Abstract][Full Text] [Related]
18. Effect of a collateral ligament sparing surgical approach on mechanical properties of equine proximal interphalangeal joint arthrodesis constructs. Bras JJ; Lillich JD; Beard WL; Anderson DE; Armbrust LJ; Frink E; Lease K Vet Surg; 2011 Jan; 40(1):73-81. PubMed ID: 21077916 [TBL] [Abstract][Full Text] [Related]
19. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 2 different LCP systems. Vidović A; Jansen D; Schwan S; Goldstein A; Ludtka C; Brehm W Tierarztl Prax Ausg G Grosstiere Nutztiere; 2020 Feb; 48(1):25-34. PubMed ID: 32059234 [TBL] [Abstract][Full Text] [Related]
20. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion. Sod GA; Mitchell CF; Hubert JD; Martin GS; Gill MS Vet Surg; 2007 Dec; 36(8):792-9. PubMed ID: 18067621 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]