These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

374 related articles for article (PubMed ID: 25394366)

  • 1. Real-time simultaneous and proportional myoelectric control using intramuscular EMG.
    Smith LH; Kuiken TA; Hargrove LJ
    J Neural Eng; 2014 Dec; 11(6):066013. PubMed ID: 25394366
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of Linear Regression Simultaneous Myoelectric Control Using Intramuscular EMG.
    Smith LH; Kuiken TA; Hargrove LJ
    IEEE Trans Biomed Eng; 2016 Apr; 63(4):737-46. PubMed ID: 26302506
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of probabilistic weights to enhance linear regression myoelectric control.
    Smith LH; Kuiken TA; Hargrove LJ
    J Neural Eng; 2015 Dec; 12(6):066030. PubMed ID: 26595317
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-time simultaneous myoelectric control by transradial amputees using linear and probability-weighted regression.
    Smith LH; Kuiken TA; Hargrove LJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():1119-23. PubMed ID: 26736462
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of surface and intramuscular EMG pattern recognition for simultaneous wrist/hand motion classification.
    Smith LH; Hargrove LJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():4223-6. PubMed ID: 24110664
    [TBL] [Abstract][Full Text] [Related]  

  • 6. On the usability of intramuscular EMG for prosthetic control: a Fitts' Law approach.
    Kamavuako EN; Scheme EJ; Englehart KB
    J Electromyogr Kinesiol; 2014 Oct; 24(5):770-7. PubMed ID: 25048642
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Two degrees of freedom quasi-static EMG-force at the wrist using a minimum number of electrodes.
    Clancy EA; Martinez-Luna C; Wartenberg M; Dai C; Farrell TR
    J Electromyogr Kinesiol; 2017 Jun; 34():24-36. PubMed ID: 28384495
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous and proportional estimation of hand kinematics from EMG during mirrored movements at multiple degrees-of-freedom.
    Muceli S; Farina D
    IEEE Trans Neural Syst Rehabil Eng; 2012 May; 20(3):371-8. PubMed ID: 22180516
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Support vector regression for improved real-time, simultaneous myoelectric control.
    Ameri A; Kamavuako EN; Scheme EJ; Englehart KB; Parker PA
    IEEE Trans Neural Syst Rehabil Eng; 2014 Nov; 22(6):1198-209. PubMed ID: 24846649
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A parallel classification strategy to simultaneous control elbow, wrist, and hand movements.
    Leone F; Gentile C; Cordella F; Gruppioni E; Guglielmelli E; Zollo L
    J Neuroeng Rehabil; 2022 Jan; 19(1):10. PubMed ID: 35090512
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Learning regularized representations of categorically labelled surface EMG enables simultaneous and proportional myoelectric control.
    Olsson AE; Malešević N; Björkman A; Antfolk C
    J Neuroeng Rehabil; 2021 Feb; 18(1):35. PubMed ID: 33588868
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Channel selection for simultaneous and proportional myoelectric prosthesis control of multiple degrees-of-freedom.
    Hwang HJ; Hahne JM; Müller KR
    J Neural Eng; 2014 Oct; 11(5):056008. PubMed ID: 25082779
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Myoelectric Control Performance of Two Degree of Freedom Hand-Wrist Prosthesis by Able-Bodied and Limb-Absent Subjects.
    Zhu Z; Li J; Boyd WJ; Martinez-Luna C; Dai C; Wang H; Wang H; Huang X; Farrell TR; Clancy EA
    IEEE Trans Neural Syst Rehabil Eng; 2022; 30():893-904. PubMed ID: 35349446
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Myoelectric Control System and Task-Specific Characteristics Affect Voluntary Use of Simultaneous Control.
    Smith LH; Kuiken TA; Hargrove LJ
    IEEE Trans Neural Syst Rehabil Eng; 2016 Jan; 24(1):109-16. PubMed ID: 25769167
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Motion Normalized Proportional Control for Improved Pattern Recognition-Based Myoelectric Control.
    Scheme E; Lock B; Hargrove L; Hill W; Kuruganti U; Englehart K
    IEEE Trans Neural Syst Rehabil Eng; 2014 Jan; 22(1):149-57. PubMed ID: 23475378
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simultaneous and Proportional Real-Time Myocontrol of Up to Three Degrees of Freedom of the Wrist and Hand.
    Nowak M; Vujaklija I; Sturma A; Castellini C; Farina D
    IEEE Trans Biomed Eng; 2023 Feb; 70(2):459-469. PubMed ID: 35881594
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of a Simultaneous Myoelectric Control Strategy for a Multi-DoF Transradial Prosthesis.
    Piazza C; Rossi M; Catalano MG; Bicchi A; Hargrove LJ
    IEEE Trans Neural Syst Rehabil Eng; 2020 Oct; 28(10):2286-2295. PubMed ID: 32804650
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Real-time, simultaneous myoelectric control using force and position-based training paradigms.
    Ameri A; Scheme EJ; Kamavuako EN; Englehart KB; Parker PA
    IEEE Trans Biomed Eng; 2014 Feb; 61(2):279-87. PubMed ID: 24058007
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wrist torque estimation during simultaneous and continuously changing movements: surface vs. untargeted intramuscular EMG.
    Kamavuako EN; Scheme EJ; Englehart KB
    J Neurophysiol; 2013 Jun; 109(11):2658-65. PubMed ID: 23515790
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of the real-time controllability of pattern recognition to conventional myoelectric control for discrete and simultaneous movements.
    Young AJ; Smith LH; Rouse EJ; Hargrove LJ
    J Neuroeng Rehabil; 2014 Jan; 11():5. PubMed ID: 24410948
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.