These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

315 related articles for article (PubMed ID: 25406342)

  • 1. New generation neonatal high frequency ventilators: effect of oscillatory frequency and working principles on performance.
    Grazioli S; Karam O; Rimensberger PC
    Respir Care; 2015 Mar; 60(3):363-70. PubMed ID: 25406342
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Neonatal and adult ICU ventilators to provide ventilation in neonates, infants, and children: a bench model study.
    Vignaux L; Piquilloud L; Tourneux P; Jolliet P; Rimensberger PC
    Respir Care; 2014 Oct; 59(10):1463-75. PubMed ID: 25118306
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro performance characteristics of high-frequency oscillatory ventilators.
    Pillow JJ; Wilkinson MH; Neil HL; Ramsden CA
    Am J Respir Crit Care Med; 2001 Sep; 164(6):1019-24. PubMed ID: 11587990
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro performance comparison of the Sensormedics 3100A and B high-frequency oscillatory ventilators.
    Custer JW; Ahmed A; Kaczka DW; Mulreany DG; Hager DN; Simon BA; Easley RB
    Pediatr Crit Care Med; 2011 Jul; 12(4):e176-80. PubMed ID: 21037502
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of imposed resistance on tidal volume with 5 neonatal nasal continuous positive airway pressure systems.
    Cook SE; Fedor KL; Chatburn RL
    Respir Care; 2010 May; 55(5):544-8. PubMed ID: 20420723
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of high-frequency neonatal ventilator performances.
    Jouvet P; Hubert P; Isabey D; Pinquier D; Dahan E; Cloup M; Harf A
    Intensive Care Med; 1997 Feb; 23(2):208-13. PubMed ID: 9069008
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tidal volume delivery during high-frequency oscillatory ventilation in adults with acute respiratory distress syndrome.
    Hager DN; Fessler HE; Kaczka DW; Shanholtz CB; Fuld MK; Simon BA; Brower RG
    Crit Care Med; 2007 Jun; 35(6):1522-9. PubMed ID: 17440422
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Provo multicenter early high-frequency oscillatory ventilation trial: improved pulmonary and clinical outcome in respiratory distress syndrome.
    Gerstmann DR; Minton SD; Stoddard RA; Meredith KS; Monaco F; Bertrand JM; Battisti O; Langhendries JP; Francois A; Clark RH
    Pediatrics; 1996 Dec; 98(6 Pt 1):1044-57. PubMed ID: 8951252
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of neonatal ventilators in volume targeted ventilation mode.
    Sharma A; Milner AD; Greenough A
    Acta Paediatr; 2007 Feb; 96(2):176-80. PubMed ID: 17429900
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relationship between oscillatory volume and oscillatory pressure in neonatal high-frequency oscillatory ventilators: an in vitro study.
    Zannin E; Rigotti C; DellacĂ  RL; Ventura ML
    Arch Dis Child; 2024 Jul; 109(8):666-672. PubMed ID: 38789116
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Volume Oscillations Delivered to a Lung Model Using 4 Different Bubble CPAP Systems.
    Poli JA; Richardson CP; DiBlasi RM
    Respir Care; 2015 Mar; 60(3):371-81. PubMed ID: 25425706
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators.
    Hatcher D; Watanabe H; Ashbury T; Vincent S; Fisher J; Froese A
    Crit Care Med; 1998 Jun; 26(6):1081-8. PubMed ID: 9635659
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the Sensormedics 3100A and Bronchotron transporter in a neonatal piglet ARDS model.
    Messier SE; Digeronimo RJ; Gillette RK
    Pediatr Pulmonol; 2009 Jul; 44(7):693-700. PubMed ID: 19499589
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Are All Oscillators Created Equal? In vitro Performance Characteristics of Eight High-Frequency Oscillatory Ventilators.
    Tingay DG; John J; Harcourt ER; Black D; Dargaville PA; Mills JF; Davis PG
    Neonatology; 2015; 108(3):220-8. PubMed ID: 26304262
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Performance of ventilators compatible with magnetic resonance imaging: a bench study.
    Chikata Y; Okuda N; Izawa M; Onodera M; Nishimura M
    Respir Care; 2015 Mar; 60(3):341-6. PubMed ID: 25492962
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volume-targeted modes of modern neonatal ventilators: how stable is the delivered tidal volume?
    Jaecklin T; Morel DR; Rimensberger PC
    Intensive Care Med; 2007 Feb; 33(2):326-35. PubMed ID: 17119922
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Are tidal volume measurements in neonatal pressure-controlled ventilation accurate?
    Chow LC; Vanderhal A; Raber J; Sola A
    Pediatr Pulmonol; 2002 Sep; 34(3):196-202. PubMed ID: 12203848
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Oscillation Transmission of Modern High-Frequency Neonatal Ventilators Under Different Lung Mechanics Conditions.
    Centorrino R; Dell'Orto V; Boussard C; Debray A; Ben-Ammar R; De Luca D
    Respir Care; 2022 Jul; 67(7):850-856. PubMed ID: 35610034
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.