BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 25407859)

  • 41. Proton versus photon deep inspiration breath hold technique in patients with hodgkin lymphoma and mediastinal radiation : A PLANNING COMPARISON OF DEEP INSPIRATION BREATH HOLD INTENSITY MODULATION RADIOTHERAPY AND INTENSITY MODULATED PROTON THERAPY.
    Baues C; Marnitz S; Engert A; Baus W; Jablonska K; Fogliata A; Vásquez-Torres A; Scorsetti M; Cozzi L
    Radiat Oncol; 2018 Jul; 13(1):122. PubMed ID: 29970105
    [TBL] [Abstract][Full Text] [Related]  

  • 42. The rationale for intensity-modulated proton therapy in geometrically challenging cases.
    Safai S; Trofimov A; Adams JA; Engelsman M; Bortfeld T
    Phys Med Biol; 2013 Sep; 58(18):6337-53. PubMed ID: 23965339
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Robustly optimized hybrid intensity-modulated proton therapy for craniospinal irradiation.
    Noufal MP; Sharma SD; Krishnan G; Sawant M; Gaikwad U; Jalali R
    J Cancer Res Ther; 2022; 18(6):1597-1603. PubMed ID: 36412417
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Dosimetric impact of systematic spot position errors in spot scanning proton therapy of head and neck tumor.
    Yasui K; Omi Y; Shimomura A; Muramatsu R; Iwata H; Ogino H; Hayashi N
    J Cancer Res Ther; 2023 Apr; 19(Supplement):S0. PubMed ID: 37147973
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Robust intensity-modulated proton therapy to reduce high linear energy transfer in organs at risk.
    An Y; Shan J; Patel SH; Wong W; Schild SE; Ding X; Bues M; Liu W
    Med Phys; 2017 Dec; 44(12):6138-6147. PubMed ID: 28976574
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Temporal lobe reactions after carbon ion radiation therapy: comparison of relative biological effectiveness-weighted tolerance doses predicted by local effect models I and IV.
    Gillmann C; Jäkel O; Schlampp I; Karger CP
    Int J Radiat Oncol Biol Phys; 2014 Apr; 88(5):1136-41. PubMed ID: 24661667
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Clinical implementation of intensity modulated proton therapy for thoracic malignancies.
    Chang JY; Li H; Zhu XR; Liao Z; Zhao L; Liu A; Li Y; Sahoo N; Poenisch F; Gomez DR; Wu R; Gillin M; Zhang X
    Int J Radiat Oncol Biol Phys; 2014 Nov; 90(4):809-18. PubMed ID: 25260491
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Improve dosimetric outcome in stage III non-small-cell lung cancer treatment using spot-scanning proton arc (SPArc) therapy.
    Li X; Kabolizadeh P; Yan D; Qin A; Zhou J; Hong Y; Guerrero T; Grills I; Stevens C; Ding X
    Radiat Oncol; 2018 Feb; 13(1):35. PubMed ID: 29486782
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Use of single-energy proton pencil beam scanning Bragg peak for intensity-modulated proton therapy FLASH treatment planning in liver-hypofractionated radiation therapy.
    Wei S; Lin H; Shi C; Xiong W; Chen CC; Huang S; Press RH; Hasan S; Chhabra AM; Choi JI; Simone CB; Kang M
    Med Phys; 2022 Oct; 49(10):6560-6574. PubMed ID: 35929404
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparing biological effectiveness guided plan optimization strategies for cranial proton therapy: potential and challenges.
    Hahn C; Heuchel L; Ödén J; Traneus E; Wulff J; Plaude S; Timmermann B; Bäumer C; Lühr A
    Radiat Oncol; 2022 Oct; 17(1):169. PubMed ID: 36273132
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Multi-scenario based robust intensity-modulated proton therapy (IMPT) plans can account for set-up errors more effectively in terms of normal tissue sparing than planning target volume (PTV) based intensity-modulated photon plans in the head and neck region.
    Stuschke M; Kaiser A; Abu Jawad J; Pöttgen C; Levegrün S; Farr J
    Radiat Oncol; 2013 Jun; 8():145. PubMed ID: 23773560
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Per-voxel constraints to minimize hot spots in linear energy transfer-guided robust optimization for base of skull head and neck cancer patients in IMPT.
    Feng H; Shan J; Anderson JD; Wong WW; Schild SE; Foote RL; Patrick CL; Tinnon KB; Fatyga M; Bues M; Patel SH; Liu W
    Med Phys; 2022 Jan; 49(1):632-647. PubMed ID: 34843119
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Robustness of IMPT treatment plans with respect to inter-fractional set-up uncertainties: impact of various beam arrangements for cranial targets.
    Hopfgartner J; Stock M; Knäusl B; Georg D
    Acta Oncol; 2013 Apr; 52(3):570-9. PubMed ID: 23244675
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Preliminary evaluation of multifield and single-field optimization for the treatment planning of spot-scanning proton therapy of head and neck cancer.
    Quan EM; Liu W; Wu R; Li Y; Frank SJ; Zhang X; Zhu XR; Mohan R
    Med Phys; 2013 Aug; 40(8):081709. PubMed ID: 23927306
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Robust optimization in lung treatment plans accounting for geometric uncertainty.
    Zhang X; Rong Y; Morrill S; Fang J; Narayanasamy G; Galhardo E; Maraboyina S; Croft C; Xia F; Penagaricano J
    J Appl Clin Med Phys; 2018 May; 19(3):19-26. PubMed ID: 29524301
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Superiority in Robustness of Multifield Optimization Over Single-Field Optimization for Pencil-Beam Proton Therapy for Oropharynx Carcinoma: An Enhanced Robustness Analysis.
    Stützer K; Lin A; Kirk M; Lin L
    Int J Radiat Oncol Biol Phys; 2017 Nov; 99(3):738-749. PubMed ID: 29280468
    [TBL] [Abstract][Full Text] [Related]  

  • 57. SU-E-T-624: Comparison of PTV+PRV-Based Optimization and Robust Optimization in Intensity-Modulated Proton Therapy.
    Liu W; Zhu X; Li X; Li Y; Zhang X; Frank S; Mohan R
    Med Phys; 2012 Jun; 39(6Part20):3849-3850. PubMed ID: 28517515
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors.
    Gu W; O'Connor D; Nguyen D; Yu VY; Ruan D; Dong L; Sheng K
    Med Phys; 2018 Apr; 45(4):1338-1350. PubMed ID: 29394454
    [TBL] [Abstract][Full Text] [Related]  

  • 59. PTV-based VMAT vs. robust IMPT for head-and-neck cancer: A probabilistic uncertainty analysis of clinical plan evaluation with the Dutch model-based selection.
    Rojo-Santiago J; Korevaar E; Perkó Z; Both S; Habraken SJM; Hoogeman MS
    Radiother Oncol; 2023 Sep; 186():109729. PubMed ID: 37301261
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A novel and individualized robust optimization method using normalized dose interval volume constraints (NDIVC) for intensity-modulated proton radiotherapy.
    Shan J; Sio TT; Liu C; Schild SE; Bues M; Liu W
    Med Phys; 2019 Jan; 46(1):382-393. PubMed ID: 30387870
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.