331 related articles for article (PubMed ID: 25410507)
1. Evaluation of the effectiveness of the angular stable locking system in patients with distal tibial fractures treated with intramedullary nailing: a multicenter randomized controlled trial.
Höntzsch D; Schaser KD; Hofmann GO; Pohlemann T; Hem ES; Rothenbach E; Krettek C; Attal R
J Bone Joint Surg Am; 2014 Nov; 96(22):1889-97. PubMed ID: 25410507
[TBL] [Abstract][Full Text] [Related]
2. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
[TBL] [Abstract][Full Text] [Related]
3. [Intramedullary nailing of the distal tibia. Does angular stable locking make a difference?].
Augat P; Bühren V
Unfallchirurg; 2015 Apr; 118(4):311-7. PubMed ID: 25835206
[TBL] [Abstract][Full Text] [Related]
4. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study.
Horn J; Linke B; Höntzsch D; Gueorguiev B; Schwieger K
Injury; 2009 Jul; 40(7):767-71. PubMed ID: 19450799
[TBL] [Abstract][Full Text] [Related]
5. Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures.
Vallier HA; Cureton BA; Patterson BM
J Orthop Trauma; 2011 Dec; 25(12):736-41. PubMed ID: 21904230
[TBL] [Abstract][Full Text] [Related]
6. Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture non-union.
Mohammed A; Saravanan R; Zammit J; King R
Int Orthop; 2008 Aug; 32(4):547-9. PubMed ID: 17410364
[TBL] [Abstract][Full Text] [Related]
7. Treatment of distal intraarticular tibial fractures: A biomechanical evaluation of intramedullary nailing vs. angle-stable plate osteosynthesis.
Kuhn S; Greenfield J; Arand C; Jarmolaew A; Appelmann P; Mehler D; Rommens PM
Injury; 2015 Oct; 46 Suppl 4():S99-S103. PubMed ID: 26542874
[TBL] [Abstract][Full Text] [Related]
8. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
[TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures.
Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P
J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777
[TBL] [Abstract][Full Text] [Related]
10. Single or double distal locking in intramedullary nailing of tibial shaft fractures: a prospective randomized study.
Hapa O; Muratli HH; Yüksel HY; Celebi L; Doğruyol D; Biçimoğlu A
Ulus Travma Acil Cerrahi Derg; 2010 Jan; 16(1):33-7. PubMed ID: 20209393
[TBL] [Abstract][Full Text] [Related]
11. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.
Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM
Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228
[TBL] [Abstract][Full Text] [Related]
12. [Treatment of adult tibial diaphysis fractures with reamed and locked intramedullary nailing].
Burç H; Dursun M; Orhun H; Gürkan V; Bayhan I
Acta Orthop Traumatol Turc; 2009; 43(1):7-13. PubMed ID: 19293610
[TBL] [Abstract][Full Text] [Related]
13. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study.
Gueorguiev B; Ockert B; Schwieger K; Wähnert D; Lawson-Smith M; Windolf M; Stoffel K
J Orthop Trauma; 2011 Jun; 25(6):340-6. PubMed ID: 21577069
[TBL] [Abstract][Full Text] [Related]
14. Angular stable locking in a novel intramedullary nail improves construct stability in a distal tibia fracture model.
Zderic I; Gueorguiev B; Blauth M; Weber A; Koch R; Dauwe J; Schader JF; Stoffel K; Finkemeier C; Hessmann M
Injury; 2022 Mar; 53(3):878-884. PubMed ID: 34782117
[TBL] [Abstract][Full Text] [Related]
15. [Borderline indications for locked intramedullary nailing of femur and tibia].
Vécsei V; Seitz H; Greitbauer M; Heinz T
Orthopade; 1996 Jun; 25(3):234-46. PubMed ID: 8766662
[TBL] [Abstract][Full Text] [Related]
16. Fracture strain and stability with additional locking screws in intramedullary nailing: a biomechanical study.
Sayana MK; Davis BJ; Kapoor B; Rahmatalla A; Maffulli N
J Trauma; 2006 May; 60(5):1053-7. PubMed ID: 16688070
[TBL] [Abstract][Full Text] [Related]
17. The clinical performance of a small diameter tibial nailing system with a mechanical distal aiming device.
Karachalios T; Babis G; Tsarouchas J; Sapkas G; Pantazopoulos T
Injury; 2000 Jul; 31(6):451-9. PubMed ID: 10831746
[TBL] [Abstract][Full Text] [Related]
18. Long-term follow-up of tibial shaft fractures treated with intramedullary nailing.
Lefaivre KA; Guy P; Chan H; Blachut PA
J Orthop Trauma; 2008 Sep; 22(8):525-9. PubMed ID: 18758282
[TBL] [Abstract][Full Text] [Related]
19. Results of angular-stable locked intramedullary nails in the treatment of distal tibia fractures.
Boyer P; Charles P; Loriaut P; Alkhaili J; Mylle G; Pelissier A; Massin P
Orthop Traumatol Surg Res; 2014 Dec; 100(8):901-5. PubMed ID: 25459452
[TBL] [Abstract][Full Text] [Related]
20. Interlocking intramedullary nailing in the treatment of tibial fractures. A report of 45 cases.
Ekeland A; Thoresen BO; Alho A; Strömsöe K; Follerås G; Haukebø A
Clin Orthop Relat Res; 1988 Jun; (231):205-15. PubMed ID: 3370875
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]