These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
331 related articles for article (PubMed ID: 25410507)
1. Evaluation of the effectiveness of the angular stable locking system in patients with distal tibial fractures treated with intramedullary nailing: a multicenter randomized controlled trial. Höntzsch D; Schaser KD; Hofmann GO; Pohlemann T; Hem ES; Rothenbach E; Krettek C; Attal R J Bone Joint Surg Am; 2014 Nov; 96(22):1889-97. PubMed ID: 25410507 [TBL] [Abstract][Full Text] [Related]
2. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures. Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426 [TBL] [Abstract][Full Text] [Related]
3. [Intramedullary nailing of the distal tibia. Does angular stable locking make a difference?]. Augat P; Bühren V Unfallchirurg; 2015 Apr; 118(4):311-7. PubMed ID: 25835206 [TBL] [Abstract][Full Text] [Related]
4. Angle stable interlocking screws improve construct stability of intramedullary nailing of distal tibia fractures: a biomechanical study. Horn J; Linke B; Höntzsch D; Gueorguiev B; Schwieger K Injury; 2009 Jul; 40(7):767-71. PubMed ID: 19450799 [TBL] [Abstract][Full Text] [Related]
5. Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures. Vallier HA; Cureton BA; Patterson BM J Orthop Trauma; 2011 Dec; 25(12):736-41. PubMed ID: 21904230 [TBL] [Abstract][Full Text] [Related]
6. Intramedullary tibial nailing in distal third tibial fractures: distal locking screws and fracture non-union. Mohammed A; Saravanan R; Zammit J; King R Int Orthop; 2008 Aug; 32(4):547-9. PubMed ID: 17410364 [TBL] [Abstract][Full Text] [Related]
8. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating. Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116 [TBL] [Abstract][Full Text] [Related]
9. Biomechanical comparison of locked plate osteosynthesis, reamed and unreamed nailing in conventional interlocking technique, and unreamed angle stable nailing in distal tibia fractures. Hoegel FW; Hoffmann S; Weninger P; Bühren V; Augat P J Trauma Acute Care Surg; 2012 Oct; 73(4):933-8. PubMed ID: 22710777 [TBL] [Abstract][Full Text] [Related]
10. Single or double distal locking in intramedullary nailing of tibial shaft fractures: a prospective randomized study. Hapa O; Muratli HH; Yüksel HY; Celebi L; Doğruyol D; Biçimoğlu A Ulus Travma Acil Cerrahi Derg; 2010 Jan; 16(1):33-7. PubMed ID: 20209393 [TBL] [Abstract][Full Text] [Related]
11. The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures. Kuhn S; Appelmann P; Pairon P; Mehler D; Rommens PM Injury; 2014 Jan; 45 Suppl 1():S81-6. PubMed ID: 24225228 [TBL] [Abstract][Full Text] [Related]
12. [Treatment of adult tibial diaphysis fractures with reamed and locked intramedullary nailing]. Burç H; Dursun M; Orhun H; Gürkan V; Bayhan I Acta Orthop Traumatol Turc; 2009; 43(1):7-13. PubMed ID: 19293610 [TBL] [Abstract][Full Text] [Related]
13. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study. Gueorguiev B; Ockert B; Schwieger K; Wähnert D; Lawson-Smith M; Windolf M; Stoffel K J Orthop Trauma; 2011 Jun; 25(6):340-6. PubMed ID: 21577069 [TBL] [Abstract][Full Text] [Related]
14. Angular stable locking in a novel intramedullary nail improves construct stability in a distal tibia fracture model. Zderic I; Gueorguiev B; Blauth M; Weber A; Koch R; Dauwe J; Schader JF; Stoffel K; Finkemeier C; Hessmann M Injury; 2022 Mar; 53(3):878-884. PubMed ID: 34782117 [TBL] [Abstract][Full Text] [Related]
15. [Borderline indications for locked intramedullary nailing of femur and tibia]. Vécsei V; Seitz H; Greitbauer M; Heinz T Orthopade; 1996 Jun; 25(3):234-46. PubMed ID: 8766662 [TBL] [Abstract][Full Text] [Related]
16. Fracture strain and stability with additional locking screws in intramedullary nailing: a biomechanical study. Sayana MK; Davis BJ; Kapoor B; Rahmatalla A; Maffulli N J Trauma; 2006 May; 60(5):1053-7. PubMed ID: 16688070 [TBL] [Abstract][Full Text] [Related]
17. The clinical performance of a small diameter tibial nailing system with a mechanical distal aiming device. Karachalios T; Babis G; Tsarouchas J; Sapkas G; Pantazopoulos T Injury; 2000 Jul; 31(6):451-9. PubMed ID: 10831746 [TBL] [Abstract][Full Text] [Related]
18. Long-term follow-up of tibial shaft fractures treated with intramedullary nailing. Lefaivre KA; Guy P; Chan H; Blachut PA J Orthop Trauma; 2008 Sep; 22(8):525-9. PubMed ID: 18758282 [TBL] [Abstract][Full Text] [Related]
19. Results of angular-stable locked intramedullary nails in the treatment of distal tibia fractures. Boyer P; Charles P; Loriaut P; Alkhaili J; Mylle G; Pelissier A; Massin P Orthop Traumatol Surg Res; 2014 Dec; 100(8):901-5. PubMed ID: 25459452 [TBL] [Abstract][Full Text] [Related]
20. Interlocking intramedullary nailing in the treatment of tibial fractures. A report of 45 cases. Ekeland A; Thoresen BO; Alho A; Strömsöe K; Follerås G; Haukebø A Clin Orthop Relat Res; 1988 Jun; (231):205-15. PubMed ID: 3370875 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]