1895 related articles for article (PubMed ID: 25413135)
1. PET attenuation correction using synthetic CT from ultrashort echo-time MR imaging.
Roy S; Wang WT; Carass A; Prince JL; Butman JA; Pham DL
J Nucl Med; 2014 Dec; 55(12):2071-7. PubMed ID: 25413135
[TBL] [Abstract][Full Text] [Related]
2. MRI-based attenuation correction for hybrid PET/MRI systems: a 4-class tissue segmentation technique using a combined ultrashort-echo-time/Dixon MRI sequence.
Berker Y; Franke J; Salomon A; Palmowski M; Donker HC; Temur Y; Mottaghy FM; Kuhl C; Izquierdo-Garcia D; Fayad ZA; Kiessling F; Schulz V
J Nucl Med; 2012 May; 53(5):796-804. PubMed ID: 22505568
[TBL] [Abstract][Full Text] [Related]
3. Magnetic resonance-based attenuation correction for PET/MR hybrid imaging using continuous valued attenuation maps.
Navalpakkam BK; Braun H; Kuwert T; Quick HH
Invest Radiol; 2013 May; 48(5):323-32. PubMed ID: 23442772
[TBL] [Abstract][Full Text] [Related]
4. MR-based attenuation correction for PET/MRI neurological studies with continuous-valued attenuation coefficients for bone through a conversion from R2* to CT-Hounsfield units.
Juttukonda MR; Mersereau BG; Chen Y; Su Y; Rubin BG; Benzinger TLS; Lalush DS; An H
Neuroimage; 2015 May; 112():160-168. PubMed ID: 25776213
[TBL] [Abstract][Full Text] [Related]
5. MR-based attenuation correction using ultrashort-echo-time pulse sequences in dementia patients.
Cabello J; Lukas M; Förster S; Pyka T; Nekolla SG; Ziegler SI
J Nucl Med; 2015 Mar; 56(3):423-9. PubMed ID: 25678486
[TBL] [Abstract][Full Text] [Related]
6. Accurate hybrid template-based and MR-based attenuation correction using UTE images for simultaneous PET/MR brain imaging applications.
Baran J; Chen Z; Sforazzini F; Ferris N; Jamadar S; Schmitt B; Faul D; Shah NJ; Cholewa M; Egan GF
BMC Med Imaging; 2018 Nov; 18(1):41. PubMed ID: 30400875
[TBL] [Abstract][Full Text] [Related]
7. Improved UTE-based attenuation correction for cranial PET-MR using dynamic magnetic field monitoring.
Aitken AP; Giese D; Tsoumpas C; Schleyer P; Kozerke S; Prieto C; Schaeffter T
Med Phys; 2014 Jan; 41(1):012302. PubMed ID: 24387523
[TBL] [Abstract][Full Text] [Related]
8. Prediction of CT Substitutes from MR Images Based on Local Diffeomorphic Mapping for Brain PET Attenuation Correction.
Wu Y; Yang W; Lu L; Lu Z; Zhong L; Huang M; Feng Y; Feng Q; Chen W
J Nucl Med; 2016 Oct; 57(10):1635-1641. PubMed ID: 27230932
[TBL] [Abstract][Full Text] [Related]
9. Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRI.
Mehranian A; Arabi H; Zaidi H
Neuroimage; 2016 Apr; 130():123-133. PubMed ID: 26853602
[TBL] [Abstract][Full Text] [Related]
10. Whole-Body PET/MR Imaging: Quantitative Evaluation of a Novel Model-Based MR Attenuation Correction Method Including Bone.
Paulus DH; Quick HH; Geppert C; Fenchel M; Zhan Y; Hermosillo G; Faul D; Boada F; Friedman KP; Koesters T
J Nucl Med; 2015 Jul; 56(7):1061-6. PubMed ID: 26025957
[TBL] [Abstract][Full Text] [Related]
11. Region specific optimization of continuous linear attenuation coefficients based on UTE (RESOLUTE): application to PET/MR brain imaging.
Ladefoged CN; Benoit D; Law I; Holm S; Kjær A; Højgaard L; Hansen AE; Andersen FL
Phys Med Biol; 2015 Oct; 60(20):8047-65. PubMed ID: 26422177
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of a 2D UNet-Based Attenuation Correction Methodology for PET/MR Brain Studies.
Presotto L; Bettinardi V; Bagnalasta M; Scifo P; Savi A; Vanoli EG; Fallanca F; Picchio M; Perani D; Gianolli L; De Bernardi E
J Digit Imaging; 2022 Jun; 35(3):432-445. PubMed ID: 35091873
[TBL] [Abstract][Full Text] [Related]
13. One registration multi-atlas-based pseudo-CT generation for attenuation correction in PET/MRI.
Arabi H; Zaidi H
Eur J Nucl Med Mol Imaging; 2016 Oct; 43(11):2021-35. PubMed ID: 27260522
[TBL] [Abstract][Full Text] [Related]
14. Rapid dual-echo ramped hybrid encoding MR-based attenuation correction (dRHE-MRAC) for PET/MR.
Jang H; Liu F; Bradshaw T; McMillan AB
Magn Reson Med; 2018 Jun; 79(6):2912-2922. PubMed ID: 28971513
[TBL] [Abstract][Full Text] [Related]
15. Fast Patch-Based Pseudo-CT Synthesis from T1-Weighted MR Images for PET/MR Attenuation Correction in Brain Studies.
Torrado-Carvajal A; Herraiz JL; Alcain E; Montemayor AS; Garcia-Cañamaque L; Hernandez-Tamames JA; Rozenholc Y; Malpica N
J Nucl Med; 2016 Jan; 57(1):136-43. PubMed ID: 26493204
[TBL] [Abstract][Full Text] [Related]
16. Impact of time-of-flight PET on quantification errors in MR imaging-based attenuation correction.
Mehranian A; Zaidi H
J Nucl Med; 2015 Apr; 56(4):635-41. PubMed ID: 25745090
[TBL] [Abstract][Full Text] [Related]
17. MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method.
An HJ; Seo S; Kang H; Choi H; Cheon GJ; Kim HJ; Lee DS; Song IC; Kim YK; Lee JS
J Nucl Med; 2016 Apr; 57(4):587-93. PubMed ID: 26697962
[TBL] [Abstract][Full Text] [Related]
18. Evaluation of Atlas-Based Attenuation Correction for Integrated PET/MR in Human Brain: Application of a Head Atlas and Comparison to True CT-Based Attenuation Correction.
Sekine T; Buck A; Delso G; Ter Voert EE; Huellner M; Veit-Haibach P; Warnock G
J Nucl Med; 2016 Feb; 57(2):215-20. PubMed ID: 26493207
[TBL] [Abstract][Full Text] [Related]
19. Improvement of attenuation correction in time-of-flight PET/MR imaging with a positron-emitting source.
Mollet P; Keereman V; Bini J; Izquierdo-Garcia D; Fayad ZA; Vandenberghe S
J Nucl Med; 2014 Feb; 55(2):329-36. PubMed ID: 24434291
[TBL] [Abstract][Full Text] [Related]
20. PET/MR brain imaging: evaluation of clinical UTE-based attenuation correction.
Aasheim LB; Karlberg A; Goa PE; Håberg A; Sørhaug S; Fagerli UM; Eikenes L
Eur J Nucl Med Mol Imaging; 2015 Aug; 42(9):1439-46. PubMed ID: 25900276
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]