200 related articles for article (PubMed ID: 25415154)
1. Tools & Techniques - Clinical: 3D transoesophageal echocardiography for selecting and guiding in percutaneous mitral valve repair using MitraClip.
Debonnaire P; Delgado V; Bax JJ; Marsan NA
EuroIntervention; 2014 Nov; 10(7):884-6. PubMed ID: 25415154
[No Abstract] [Full Text] [Related]
2. Incremental value of three-dimensional transoesophageal echocardiography for guiding double percutaneous MitraClip ® implantation in a 'no option' patient.
Ciobanu A; Bennett S; Azam M; Clark A; Vinereanu D
Eur J Echocardiogr; 2011 Feb; 12(2):E11. PubMed ID: 20876188
[TBL] [Abstract][Full Text] [Related]
3. Percutaneous Transcatheter Edge-to-Edge MitraClip Technique: A Practical "Step-by-Step" 3-Dimensional Transesophageal Echocardiography Guide.
Bushari LI; Reeder GS; Eleid MF; Chandrasekaran K; Eriquez-Sarano M; Rihal CS; Maalouf JF
Mayo Clin Proc; 2019 Jan; 94(1):89-102. PubMed ID: 30611459
[TBL] [Abstract][Full Text] [Related]
4. Guidance of the MitraClip
Labrousse L; Dijos M; Leroux L; Oses P; Seguy B; Markof M; Lafitte S
Arch Cardiovasc Dis; 2018; 111(6-7):432-440. PubMed ID: 30041732
[TBL] [Abstract][Full Text] [Related]
5. Isolated mitral valve P3 prolapse with severe regurgitation - transoesophageal 2D/3D echo-guidance in transapical -artificial neochordae implantation in challenging patient.
Kurnicka K; Wrobel K; Zakarkaite D; Biederman A; Pruszczyk P
Acta Cardiol; 2017 Jun; 72(3):347-348. PubMed ID: 28636512
[No Abstract] [Full Text] [Related]
6. Transesophageal echocardiography during MitraClip® procedure.
Guarracino F; Baldassarri R; Ferro B; Giannini C; Bertini P; Petronio AS; Di Bello V; Landoni G; Alfieri O
Anesth Analg; 2014 Jun; 118(6):1188-96. PubMed ID: 24842173
[TBL] [Abstract][Full Text] [Related]
7. Paravalvular leak after mitral valve replacement: advantage of 3D echo.
Singh SP; Hasija S; Chauhan S
Ann Card Anaesth; 2014; 17(2):137-8. PubMed ID: 24732614
[No Abstract] [Full Text] [Related]
8. Feasibility of anterior mitral leaflet flail repair with transapical beating-heart neochord implantation.
Colli A; Manzan E; Zucchetta F; Sarais C; Pittarello D; Gerosa G
JACC Cardiovasc Interv; 2014 Nov; 7(11):1320-1. PubMed ID: 25326735
[No Abstract] [Full Text] [Related]
9. 3D echocardiography in cardiac surgery.
Saxena P; Malouf JF; Click R; Suri RM
J Card Surg; 2014 Jan; 29(1):51-4. PubMed ID: 24304195
[TBL] [Abstract][Full Text] [Related]
10. Real-time 3-dimensional transesophageal echocardiography in the assessment of ventriculoatrial shunt (Gerbode defect) complicating simultaneous mitral and tricuspid valve repair.
Chamsi-Pasha MA; Sayyed SH; Moulton MJ
J Am Coll Cardiol; 2014 Apr; 63(15):e37. PubMed ID: 24583307
[No Abstract] [Full Text] [Related]
11. How should I treat a challenging case of MitraClip implantation?
Duino V; Fiocca L; Musumeci G; Cerchierini E; Gori M; D'Elia E; Ferrero P; Iacovoni A; Valsecchi O; Maisano F; Senni M; Feldman T; Smart S; Bozdag-Turan I; Kische S; Paranskaya L; Ortak J; Ince H
EuroIntervention; 2014 Nov; 10(7):887-90. PubMed ID: 24755272
[TBL] [Abstract][Full Text] [Related]
12. MitraClip procedure for the treatment of a pseudo-cleft in the posterior mitral leaflet.
Öztürk C; Schueler R; Werner N; Nickenig G; Hammerstingl C
Eur Heart J Cardiovasc Imaging; 2015 Jan; 16(1):112. PubMed ID: 25114030
[No Abstract] [Full Text] [Related]
13. 4-Dimensional Intracardiac Echocardiography in Transcatheter Mitral Valve Repair With the Mitraclip System.
Sanchez CE; Yakubov SJ; Singh G; Rogers JH; Kander NH; Tang GHL
JACC Cardiovasc Imaging; 2021 Oct; 14(10):2033-2040. PubMed ID: 33454248
[No Abstract] [Full Text] [Related]
14. Transcatheter Mitral Valve Repair Using the Edge-to-Edge Clip.
Nyman CB; Mackensen GB; Jelacic S; Little SH; Smith TW; Mahmood F
J Am Soc Echocardiogr; 2018 Apr; 31(4):434-453. PubMed ID: 29482977
[TBL] [Abstract][Full Text] [Related]
15. Transesophageal echocardiography in NeoChord procedure.
Demetrio P; Andrea C; Gianclaudio F; Antonio M; Gino G; Carlo O
Ann Card Anaesth; 2015; 18(2):191-7. PubMed ID: 25849688
[TBL] [Abstract][Full Text] [Related]
16. Trileaflet Mitral Valve Treated with the MitraClip® System.
Rodríguez-Santamarta M; Estévez-Loureiro R; Benito-González T; Gualis J; Garrote C; Pérez de Prado A; Fernández-Vázquez F
J Heart Valve Dis; 2017 Sep; 26(5):589-591. PubMed ID: 29762929
[TBL] [Abstract][Full Text] [Related]
17. Two- and three-dimensional transoesophageal echocardiography in large swine used as model for transcatheter heart valve therapies: standard planes and values.
Sündermann SH; Cesarovic N; Falk V; Bettex D
Interact Cardiovasc Thorac Surg; 2016 May; 22(5):580-6. PubMed ID: 26831678
[TBL] [Abstract][Full Text] [Related]
18. Mechanism and severity of mitral regurgitation by transesophageal echocardiography in patients referred for percutaneous valve repair.
Grayburn PA; Roberts BJ; Aston S; Anwar A; Hebeler RF; Brown DL; Mack MJ
Am J Cardiol; 2011 Sep; 108(6):882-7. PubMed ID: 21741608
[TBL] [Abstract][Full Text] [Related]
19. Successful repair for isolated cleft mitral valve diagnosed by three-dimensional transesophageal echocardiography.
Matsue H; Masai T; Yoshikawa Y; Kawamura M; Miyata T
J Heart Valve Dis; 2012 May; 21(3):412. PubMed ID: 22808853
[No Abstract] [Full Text] [Related]
20. Usefulness of 3D transoesophageal echocardiography for guiding wires and closure devices in mitral perivalvular leaks.
Becerra JM; Almeria C; de Isla LP; Zamorano J
Eur J Echocardiogr; 2009 Dec; 10(8):979-81. PubMed ID: 19752009
[TBL] [Abstract][Full Text] [Related]