3. [Reproducibility of dynamic contour tonometry. Comparison with TonoPenXL and Goldmann applanation tonometry - a clinical study on 323 normal eyes]. Viestenz A; Langenbucher A; Viestenz A Klin Monbl Augenheilkd; 2006 Oct; 223(10):813-9. PubMed ID: 17063423 [TBL] [Abstract][Full Text] [Related]
4. [Dynamic Contour Tonometry and Goldmann Applanation Tonometry: Difference of Intraocular Pressure Values Between Eyes with and without Glaucomatous Damage in Thin Corneas]. Umurhan Akkan JC; Akkan F; Sezgin Akcay BI; Ayintap E; Tuncer K Klin Monbl Augenheilkd; 2015 Oct; 232(10):1190-7. PubMed ID: 26512850 [TBL] [Abstract][Full Text] [Related]
5. Comparison of dynamic contour tonometry and goldmann applanation tonometry in glaucoma patients and healthy subjects. Barleon L; Hoffmann EM; Berres M; Pfeiffer N; Grus FH Am J Ophthalmol; 2006 Oct; 142(4):583-90. PubMed ID: 17011849 [TBL] [Abstract][Full Text] [Related]
6. [Comparison of dynamic contour tonometry, Goldmann and pneumotonometer in ocular hypertension patients and their relationship to pachymetry and ocular pulse amplitude]. Colás-Tomás T; Prieto-Del Cura M; Villafruela-Güemes I; Clariana-Martín A; Valdivia-Pérez A Arch Soc Esp Oftalmol; 2012 Dec; 87(12):401-6. PubMed ID: 23121701 [TBL] [Abstract][Full Text] [Related]
7. Effect of corneal thickness on dynamic contour, rebound, and goldmann tonometry. Martinez-de-la-Casa JM; Garcia-Feijoo J; Vico E; Fernandez-Vidal A; Benitez del Castillo JM; Wasfi M; Garcia-Sanchez J Ophthalmology; 2006 Dec; 113(12):2156-62. PubMed ID: 16996599 [TBL] [Abstract][Full Text] [Related]
8. Intraocular pressure measurement precision with the Goldmann applanation, dynamic contour, and ocular response analyzer tonometers. Kotecha A; White E; Schlottmann PG; Garway-Heath DF Ophthalmology; 2010 Apr; 117(4):730-7. PubMed ID: 20122737 [TBL] [Abstract][Full Text] [Related]
9. [Goldmann applanation tonometry and dynamic contour tonometry. Comparison of intraocular pressure measurements in the course of product certification according to EN ISO 8612:2001]. Hoffmann EM; Pfeiffer N; Barleon L; Grus FH Ophthalmologe; 2006 Apr; 103(4):317-20. PubMed ID: 16520991 [TBL] [Abstract][Full Text] [Related]
10. Comparisons between Pascal dynamic contour tonometry, the TonoPen, and Goldmann applanation tonometry in patients with glaucoma. Salvetat ML; Zeppieri M; Tosoni C; Brusini P Acta Ophthalmol Scand; 2007 May; 85(3):272-9. PubMed ID: 17488456 [TBL] [Abstract][Full Text] [Related]
11. The relative effects of corneal thickness and age on Goldmann applanation tonometry and dynamic contour tonometry. Kotecha A; White ET; Shewry JM; Garway-Heath DF Br J Ophthalmol; 2005 Dec; 89(12):1572-5. PubMed ID: 16299132 [TBL] [Abstract][Full Text] [Related]
12. Clinical comparison of pascal dynamic contour tonometry and goldmann applanation tonometry in asymmetric open-angle glaucoma. Sullivan-Mee M; Halverson KD; Qualls C J Glaucoma; 2007 Dec; 16(8):694-9. PubMed ID: 18091457 [TBL] [Abstract][Full Text] [Related]
13. [Clinical evaluation of the Pascal dynamic contour tonometer]. Detry-Morel M; Jamart J; Detry MB; Ledoux A; Pourjavan S J Fr Ophtalmol; 2007 Mar; 30(3):260-70. PubMed ID: 17417152 [TBL] [Abstract][Full Text] [Related]
14. Comparison of dynamic contour tonometry with Goldmann applanation tonometry following Descemet's stripping automated endothelial keratoplasty (DSAEK). Bochmann F; Kaufmann C; Becht C; Bachmann LM; Thiel MA Klin Monbl Augenheilkd; 2009 Apr; 226(4):241-4. PubMed ID: 19384775 [TBL] [Abstract][Full Text] [Related]
15. Comparison of Goldmann applanation, non-contact, dynamic contour and tonopen tonometry measurements in healthy and glaucomatous eyes, and effect of central corneal thickness on the measurement results. Yildiz A; Yasar T Med Glas (Zenica); 2018 Aug; 15(2):152-157. PubMed ID: 30047543 [TBL] [Abstract][Full Text] [Related]
16. Comparison of Goldmann applanation tonometry and dynamic contour tonometry in healthy and glaucomatous eyes. Ceruti P; Morbio R; Marraffa M; Marchini G Eye (Lond); 2009 Feb; 23(2):262-9. PubMed ID: 18219335 [TBL] [Abstract][Full Text] [Related]
17. Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, ocular response analyzer, and Goldmann tonometry in glaucomatous eyes. Hager A; Loge K; Schroeder B; Füllhas MO; Wiegand W J Glaucoma; 2008 Aug; 17(5):361-5. PubMed ID: 18703945 [TBL] [Abstract][Full Text] [Related]
18. Intraocular pressure and ocular pulse amplitude comparisons in different types of glaucoma using dynamic contour tonometry. Punjabi OS; Ho HK; Kniestedt C; Bostrom AG; Stamper RL; Lin SC Curr Eye Res; 2006 Oct; 31(10):851-62. PubMed ID: 17050277 [TBL] [Abstract][Full Text] [Related]
19. Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature. Andreanos K; Koutsandrea C; Papaconstantinou D; Diagourtas A; Kotoulas A; Dimitrakas P; Moschos MM Clin Ophthalmol; 2016; 10():2477-2484. PubMed ID: 28003737 [TBL] [Abstract][Full Text] [Related]