These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
348 related articles for article (PubMed ID: 25421390)
1. The added predictive value of biphasic events in ST analysis of the fetal electrocardiogram for intrapartum fetal monitoring. Becker JH; Krikhaar A; Schuit E; Mårtendal A; Maršál K; Kwee A; Visser GH; Amer-Wåhlin I Acta Obstet Gynecol Scand; 2015 Feb; 94(2):175-82. PubMed ID: 25421390 [TBL] [Abstract][Full Text] [Related]
2. Delay in intervention increases neonatal morbidity in births monitored with cardiotocography and ST-waveform analysis. Kessler J; Moster D; Albrechtsen S Acta Obstet Gynecol Scand; 2014 Feb; 93(2):175-81. PubMed ID: 24251909 [TBL] [Abstract][Full Text] [Related]
3. Predictive value of the baseline T-QRS ratio of the fetal electrocardiogram in intrapartum fetal monitoring: a prospective cohort study. Becker JH; Kuipers LJ; Schuit E; Visser GH; Van Den Akker ES; Van Beek E; Bolte AC; Rijnders RJ; Mol BW; Porath MM; Drogtrop AP; Schuitemaker NW; Willekes C; Westerhuis ME; Moons KG; Kwee A Acta Obstet Gynecol Scand; 2012 Feb; 91(2):189-97. PubMed ID: 22066545 [TBL] [Abstract][Full Text] [Related]
4. Intrapartum monitoring with cardiotocography and ST-waveform analysis in breech presentation: an observational study. Kessler J; Moster D; Albrechtsen S BJOG; 2015 Mar; 122(4):528-35. PubMed ID: 25040705 [TBL] [Abstract][Full Text] [Related]
5. Identification of cases with adverse neonatal outcome monitored by cardiotocography versus ST analysis: secondary analysis of a randomized trial. Westerhuis ME; Porath MM; Becker JH; Van Den Akker ES; Van Beek E; Van Dessel HJ; Drogtrop AP; Van Geijn HP; Graziosi GC; Groenendaal F; Van Lith JM; Mol BW; Moons KG; Nijhuis JG; Oei SG; Oosterbaan HP; Rijnders RJ; Schuitemaker NW; Wijnberger LD; Willekes C; Wouters MG; Visser GH; Kwee A Acta Obstet Gynecol Scand; 2012 Jul; 91(7):830-7. PubMed ID: 22536843 [TBL] [Abstract][Full Text] [Related]
6. Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial. Amer-Wåhlin I; Hellsten C; Norén H; Hagberg H; Herbst A; Kjellmer I; Lilja H; Lindoff C; Månsson M; Mårtensson L; Olofsson P; Sundström A; Marsál K Lancet; 2001 Aug; 358(9281):534-8. PubMed ID: 11520523 [TBL] [Abstract][Full Text] [Related]
7. ST analysis of the fetal electrocardiogram in intrapartum fetal monitoring: a meta-analysis. Becker JH; Bax L; Amer-Wåhlin I; Ojala K; Vayssière C; Westerhuis ME; Mol BW; Visser GH; Maršál K; Kwee A; Moons KG Obstet Gynecol; 2012 Jan; 119(1):145-54. PubMed ID: 22183222 [TBL] [Abstract][Full Text] [Related]
8. STAN S21 fetal heart monitor for fetal surveillance during labor: an observational study in 637 patients. Kwee A; van der Hoorn-van den Beld CW; Veerman J; Dekkers AH; Visser GH J Matern Fetal Neonatal Med; 2004 Jun; 15(6):400-7. PubMed ID: 15280112 [TBL] [Abstract][Full Text] [Related]
9. The importance of the learning process in ST analysis interpretation and its impact in improving clinical and neonatal outcomes. Timonen S; Holmberg K Am J Obstet Gynecol; 2018 Jun; 218(6):620.e1-620.e7. PubMed ID: 29577914 [TBL] [Abstract][Full Text] [Related]
10. [Intrapartum fetal monitoring by electrocardiography]. Xiong Q Zhonghua Fu Chan Ke Za Zhi; 1990 Sep; 25(5):291-4, 317. PubMed ID: 2282853 [TBL] [Abstract][Full Text] [Related]
11. Significant reduction in umbilical artery metabolic acidosis after implementation of intrapartum ST waveform analysis of the fetal electrocardiogram. Landman AJEMC; Immink-Duijker ST; Mulder EJH; Koster MPH; Xodo S; Visser GHA; Groenendaal F; Kwee A Am J Obstet Gynecol; 2019 Jul; 221(1):63.e1-63.e13. PubMed ID: 30826340 [TBL] [Abstract][Full Text] [Related]
12. A randomised clinical trial on cardiotocography plus fetal blood sampling versus cardiotocography plus ST-analysis of the fetal electrocardiogram (STAN) for intrapartum monitoring. Westerhuis ME; Moons KG; van Beek E; Bijvoet SM; Drogtrop AP; van Geijn HP; van Lith JM; Mol BW; Nijhuis JG; Oei SG; Porath MM; Rijnders RJ; Schuitemaker NW; van der Tweel I; Visser GH; Willekes C; Kwee A BMC Pregnancy Childbirth; 2007 Jul; 7():13. PubMed ID: 17655764 [TBL] [Abstract][Full Text] [Related]
13. Randomised trial of cardiotocography alone or with ST waveform analysis for intrapartum monitoring. Westgate J; Harris M; Curnow JS; Greene KR Lancet; 1992 Jul; 340(8813):194-8. PubMed ID: 1353134 [TBL] [Abstract][Full Text] [Related]
14. Fetal electrocardiogram ST-segment analysis and prediction of neonatal acidosis. Vayssiere C; Haberstich R; Sebahoun V; David E; Roth E; Langer B Int J Gynaecol Obstet; 2007 May; 97(2):110-4. PubMed ID: 17368461 [TBL] [Abstract][Full Text] [Related]
15. Fetal electrocardiography in labor and neonatal outcome: data from the Swedish randomized controlled trial on intrapartum fetal monitoring. Norén H; Amer-Wåhlin I; Hagberg H; Herbst A; Kjellmer I; Marşál K; Olofsson P; Rosén KG Am J Obstet Gynecol; 2003 Jan; 188(1):183-92. PubMed ID: 12548215 [TBL] [Abstract][Full Text] [Related]
16. Cardiotocography alone is outdated and ST analysis is the way forward in fetal monitoring: FOR: Does the use of ST analysis in conjunction with cardiotocography improve perinatal outcome and/or reduce interventions for fetal distress? Visser GH; Kwee A BJOG; 2016 Sep; 123(10):1636. PubMed ID: 27531326 [No Abstract] [Full Text] [Related]
17. ST waveform analysis versus cardiotocography alone for intrapartum fetal monitoring: a meta-analysis of randomized trials. Potti S; Berghella V Am J Perinatol; 2012 Sep; 29(8):657-64. PubMed ID: 22639349 [TBL] [Abstract][Full Text] [Related]
18. Is intrapartum fever associated with ST-waveform changes of the fetal electrocardiogram? A retrospective cohort study. Becker JH; van Rijswijk J; Versteijnen B; Evers AC; van den Akker ES; van Beek E; Bolte AC; Rijnders RJ; Mol BW; Moons Kg; Porath MM; Drogtrop AP; Schuitemaker NW; Willekes C; Westerhuis ME; Visser GH; Kwee A BJOG; 2012 Oct; 119(11):1410-6. PubMed ID: 22827811 [TBL] [Abstract][Full Text] [Related]
19. Fetal blood sampling in addition to intrapartum ST-analysis of the fetal electrocardiogram: evaluation of the recommendations in the Dutch STAN® trial. Becker JH; Westerhuis ME; Sterrenburg K; van den Akker ES; van Beek E; Bolte AC; van Dessel TJ; Drogtrop AP; van Geijn HP; Graziosi GC; van Lith JM; Mol BW; Moons KG; Nijhuis JG; Oei SG; Oosterbaan HP; Porath MM; Rijnders RJ; Schuitemaker NW; Wijnberger LD; Willekes C; Visser GH; Kwee A BJOG; 2011 Sep; 118(10):1239-46. PubMed ID: 21668767 [TBL] [Abstract][Full Text] [Related]
20. ST waveform analysis versus cardiotocography alone for intrapartum fetal monitoring: a systematic review and meta-analysis of randomized trials. Blix E; Brurberg KG; Reierth E; Reinar LM; Øian P Acta Obstet Gynecol Scand; 2016 Jan; 95(1):16-27. PubMed ID: 26610052 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]