BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 25422185)

  • 1. Comparison of automated breast volume scanning and hand- held ultrasound in the detection of breast cancer: an analysis of 5,566 patient evaluations.
    Choi WJ; Cha JH; Kim HH; Shin HJ; Kim H; Chae EY; Hong MJ
    Asian Pac J Cancer Prev; 2014; 15(21):9101-5. PubMed ID: 25422185
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of automated versus hand-held breast US in supplemental screening in asymptomatic women with dense breasts: is there a difference regarding woman preference, lesion detection and lesion characterization?
    Tutar B; Esen Icten G; Guldogan N; Kara H; Arıkan AE; Tutar O; Uras C
    Arch Gynecol Obstet; 2020 May; 301(5):1257-1265. PubMed ID: 32215718
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnostic performance of combined use of automated breast volume scanning & hand-held ultrasound for breast lesions.
    Liu J; Zhou Y; Wu J; Li P; Liang X; Duan H; Wu X; Hou X; Li X
    Indian J Med Res; 2021 Aug; 154(2):347-354. PubMed ID: 35295015
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Usefulness of automated breast volume scanner (ABVS) for monitoring tumor response to neoadjuvant treatment in breast cancer patients: preliminary results.
    D'Angelo A; Rinaldi P; Belli P; D'Amico R; Carlino G; Grippo C; Giuliani M; Orlandi A; Infante A; Manfredi R
    Eur Rev Med Pharmacol Sci; 2019 Jan; 23(1):225-231. PubMed ID: 30657564
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diagnostic Performance of Automated Breast Volume Scanning (ABVS) Compared to Handheld Ultrasonography With Breast MRI as the Gold Standard.
    Schmachtenberg C; Fischer T; Hamm B; Bick U
    Acad Radiol; 2017 Aug; 24(8):954-961. PubMed ID: 28336007
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Differentiation of benign and malignant breast lesions: a comparison between automatically generated breast volume scans and handheld ultrasound examinations.
    Wang HY; Jiang YX; Zhu QL; Zhang J; Dai Q; Liu H; Lai XJ; Sun Q
    Eur J Radiol; 2012 Nov; 81(11):3190-200. PubMed ID: 22386134
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of an automated breast volume ultrasound system for assessment of the pre-operative extent of pure ductal carcinoma in situ: comparison with a conventional handheld ultrasound examination.
    Li N; Jiang YX; Zhu QL; Zhang J; Dai Q; Liu H; Yang Q; Wang HY; Lai XJ; Sun Q
    Ultrasound Med Biol; 2013 Dec; 39(12):2255-63. PubMed ID: 24035630
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of an automated breast volume scanner according to the fifth edition of BI-RADS for breast ultrasound compared with hand-held ultrasound.
    Choi EJ; Choi H; Park EH; Song JS; Youk JH
    Eur J Radiol; 2018 Feb; 99():138-145. PubMed ID: 29362145
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Initial experience of automated breast volume scanning (ABVS) and ultrasound elastography in predicting breast cancer subtypes and staging.
    Wang XL; Tao L; Zhou XL; Wei H; Sun JW
    Breast; 2016 Dec; 30():130-135. PubMed ID: 27718417
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results.
    Golatta M; Franz D; Harcos A; Junkermann H; Rauch G; Scharf A; Schuetz F; Sohn C; Heil J
    Eur J Radiol; 2013 Aug; 82(8):e332-6. PubMed ID: 23540947
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Breast cancer staging: Combined digital breast tomosynthesis and automated breast ultrasound versus magnetic resonance imaging.
    Girometti R; Tomkova L; Cereser L; Zuiani C
    Eur J Radiol; 2018 Oct; 107():188-195. PubMed ID: 30292265
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Three-Dimensional Assessment of Automated Breast Volume Scanner Compared with Handheld Ultrasound in Pre-Operative Breast Invasive Ductal Carcinomas: A Pilot Study of 51 Cases.
    Xu C; Wei S; Xie Y; Guan X; Yang B
    Ultrasound Med Biol; 2016 Sep; 42(9):2089-96. PubMed ID: 27339762
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Automated breast ultrasound: lesion detection and BI-RADS classification--a pilot study.
    Wenkel E; Heckmann M; Heinrich M; Schwab SA; Uder M; Schulz-Wendtland R; Bautz WA; Janka R
    Rofo; 2008 Sep; 180(9):804-8. PubMed ID: 18704878
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of eighty-one cases with breast lesions using automated breast volume scanner and comparison with handheld ultrasound.
    Lin X; Wang J; Han F; Fu J; Li A
    Eur J Radiol; 2012 May; 81(5):873-8. PubMed ID: 21420814
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative study of automated breast 3-D ultrasound and handheld B-mode ultrasound for differentiation of benign and malignant breast masses.
    Chen L; Chen Y; Diao XH; Fang L; Pang Y; Cheng AQ; Li WP; Wang Y
    Ultrasound Med Biol; 2013 Oct; 39(10):1735-42. PubMed ID: 23849390
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Sonographic criteria for the differentiation of benign and malignant breast lesions using real-time spatial compound imaging in combination with XRES adaptive image processing].
    Hahn M; Roessner L; Krainick-Strobel U; Gruber IV; Krämer B; Gall C; Siegmann KC; Wallwiener D; Kagan KO
    Ultraschall Med; 2012 Jun; 33(3):270-4. PubMed ID: 20614412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Breast cancers initially detected by hand-held ultrasound: detection performance of radiologists using automated breast ultrasound data.
    Chang JM; Moon WK; Cho N; Park JS; Kim SJ
    Acta Radiol; 2011 Feb; 52(1):8-14. PubMed ID: 21498319
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Recall rate of screening ultrasound with automated breast volumetric scanning (ABVS) in women with dense breasts: a first quarter experience.
    Arleo EK; Saleh M; Ionescu D; Drotman M; Min RJ; Hentel K
    Clin Imaging; 2014; 38(4):439-444. PubMed ID: 24768327
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of handheld ultrasound and automated breast ultrasound in women recalled after mammography screening.
    Hellgren R; Dickman P; Leifland K; Saracco A; Hall P; Celebioglu F
    Acta Radiol; 2017 May; 58(5):515-520. PubMed ID: 27565633
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Is there an extraclinical value of automated breast volume scanner compared with hand-held ultrasound?: A pilot study.
    Zhan J; Diao XH; Pang Y; Wang Y; Chen L; Chen Y
    Medicine (Baltimore); 2017 Sep; 96(37):e7765. PubMed ID: 28906361
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.