These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

432 related articles for article (PubMed ID: 25425709)

  • 1. Effect of applying positive pressure with or without endotracheal suctioning during extubation: a laboratory study.
    Andreu MF; Salvati IG; Donnianni MC; Ibañez B; Cotignola M; Bezzi M
    Respir Care; 2014 Dec; 59(12):1905-11. PubMed ID: 25425709
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system.
    Dave MH; Frotzler A; Madjdpour C; Koepfer N; Weiss M
    J Intensive Care Med; 2011; 26(5):326-9. PubMed ID: 21300670
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Positive Airway Pressure at Extubation Minimizes Subglottic Secretion Leak In Vitro.
    Wang TP; Li HH; Lin HL
    J Clin Med; 2022 Jan; 11(2):. PubMed ID: 35054001
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effects of extubation with an inflated versus deflated endotracheal tube cuff on endotracheal fluid volume in the dog.
    Vance A; Hofmeister EH; Laas C; Williams J
    Vet Anaesth Analg; 2011 May; 38(3):203-7. PubMed ID: 21492385
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of closed system suction on airway pressures when using the Servo 300 ventilator.
    Frengley RW; Closey DN; Sleigh JW; Torrance JM
    Crit Care Resusc; 2001 Dec; 3(4):230-5. PubMed ID: 16573511
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Can ventilator settings reduce the negative effects of endotracheal suctioning? Investigations in a mechanical lung model.
    Nakstad ER; Opdahl H; Heyerdahl F; Borchsenius F; Skjønsberg OH
    BMC Anesthesiol; 2016 Jun; 16(1):30. PubMed ID: 27350249
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Physiological responses to endotracheal and oral suctioning in paediatric patients: the influence of endotracheal tube sizes and suction pressures.
    Singh NC; Kissoon N; Frewen T; Tiffin N
    Clin Intensive Care; 1991; 2(6):345-50. PubMed ID: 10149098
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An Artificial Cough Maneuver to Remove Secretions From Below the Endotracheal Tube Cuff.
    Zanella A; Florio G; Rezoagli E; Pastore M; Cadringer P; Biancolilli O; Carlesso E; Scaravilli V; Ristagno G; Pesenti AM
    Respir Care; 2019 Apr; 64(4):372-383. PubMed ID: 30622174
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Manual ventilation and open suction procedures contribute to negative pressures in a mechanical lung model.
    Nakstad ER; Opdahl H; Heyerdahl F; Borchsenius F; Skjønsberg OH
    BMJ Open Respir Res; 2017; 4(1):e000176. PubMed ID: 28725445
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Could "safe practice" be compromising safe practice? Should anesthetists have to deflate the cuff of the endotracheal tube before extubation?
    Priebe HJ
    Minerva Anestesiol; 2016 Feb; 82(2):236-9. PubMed ID: 26126979
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A novel technique for assessment of post-extubation airway obstruction can successfully replace the conventional cuff leak test: a pilot study.
    Tokunaga K; Ejima T; Nakashima T; Kuwahara M; Narimatsu N; Sagishima K; Mizumoto T; Sakagami T; Yamamoto T
    BMC Anesthesiol; 2022 Feb; 22(1):38. PubMed ID: 35105303
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Endotracheal Tube Seal and Suction Performance in a Novel Biorealistic Tracheal Model.
    Rozycki SK; Dixon FP; Yopp MA; Maxvold NJ; Rubin BK
    Respir Care; 2015 Aug; 60(8):1113-9. PubMed ID: 25944945
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Suctioning through a double-lumen endotracheal tube helps to prevent alveolar collapse and to preserve ventilation.
    Reissmann H; Böhm SH; Suárez-Sipmann F; Tusman G; Buschmann C; Maisch S; Pesch T; Thamm O; Plümers C; Schulte am Esch J; Hedenstierna G
    Intensive Care Med; 2005 Mar; 31(3):431-40. PubMed ID: 15690150
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants.
    Spence K; Gillies D; Waterworth L
    Cochrane Database Syst Rev; 2003; (3):CD003309. PubMed ID: 12917961
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The impact of closed endotracheal suctioning systems on mechanical ventilator performance.
    El Masry A; Williams PF; Chipman DW; Kratohvil JP; Kacmarek RM
    Respir Care; 2005 Mar; 50(3):345-53. PubMed ID: 15737244
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effects of closed endotracheal suction on ventilation during conventional and high-frequency oscillatory ventilation.
    Kiraly NJ; Tingay DG; Mills JF; Morley CJ; Dargaville PA; Copnell B
    Pediatr Res; 2009 Oct; 66(4):400-4. PubMed ID: 19581839
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Deep versus shallow suction of endotracheal tubes in ventilated neonates and young infants.
    Gillies D; Spence K
    Cochrane Database Syst Rev; 2011 Jul; 2011(7):CD003309. PubMed ID: 21735391
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physiologic impact of closed-system endotracheal suctioning in spontaneously breathing patients receiving mechanical ventilation.
    Seymour CW; Cross BJ; Cooke CR; Gallop RL; Fuchs BD
    Respir Care; 2009 Mar; 54(3):367-74. PubMed ID: 19245731
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Variables affecting leakage past endotracheal tube cuffs: a bench study.
    Pitts R; Fisher D; Sulemanji D; Kratohvil J; Jiang Y; Kacmarek R
    Intensive Care Med; 2010 Dec; 36(12):2066-73. PubMed ID: 20852839
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Warning! Suctioning. A lung model evaluation of closed suctioning systems.
    Stenqvist O; Lindgren S; Kárason S; Söndergaard S; Lundin S
    Acta Anaesthesiol Scand; 2001 Feb; 45(2):167-72. PubMed ID: 11167161
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 22.