These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 25430195)

  • 1. Measuring the x-ray resolving power of bent potassium acid phthalate diffraction crystals.
    Haugh MJ; Wu M; Jacoby KD; Loisel GP
    Rev Sci Instrum; 2014 Nov; 85(11):11D619. PubMed ID: 25430195
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measuring and predicting the diffraction properties of cylindrically bent potassium acid phthalate, KAP(001), crystals.
    Haugh MJ; Jacoby KD
    Rev Sci Instrum; 2017 Feb; 88(2):023113. PubMed ID: 28249466
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement and models of bent KAP(001) crystal integrated reflectivity and resolution (invited).
    Loisel GP; Wu M; Stolte W; Kruschwitz C; Lake P; Dunham GS; Bailey JE; Rochau GA
    Rev Sci Instrum; 2016 Nov; 87(11):11D502. PubMed ID: 27910652
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A methodology for calibrating wavelength dependent spectral resolution for crystal spectrometers.
    Loisel G; Bailey JE; Rochau GA; Dunham GS; Nielsen-Weber LB; Ball CR
    Rev Sci Instrum; 2012 Oct; 83(10):10E133. PubMed ID: 23126954
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diffraction properties of cylindrically bent KAP crystals in energy range of 2.3-7.5  keV using synchrotron radiation.
    Wu M; Kruschwitz CA; Lake P; Loisel GP; Bailey JE; Stolte WC
    Appl Opt; 2021 Jan; 60(3):558-570. PubMed ID: 33690429
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Integrated x-ray reflectivity measurements of elliptically curved pentaerythritol crystals.
    Haugh MJ; Regan SP; Jacoby KD; Ross PW; Magoon J; Barrios MA; Emig JA; Shoup MJ; Fournier KB
    Rev Sci Instrum; 2012 Oct; 83(10):10E122. PubMed ID: 23126944
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultra-thin curved transmission crystals for high resolving power (up to E/ΔE = 6300) x-ray spectroscopy in the 6-13  keV energy range.
    Seely JF; Hudson LT; Glover JL; Henins A; Pereira N
    Opt Lett; 2014 Dec; 39(24):6839-42. PubMed ID: 25503010
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measuring the diffraction properties of an imaging quartz(211) crystal.
    Haugh MJ; Jacoby KD; Koch JA; Chen H; Hill KW; Schneider MB
    Rev Sci Instrum; 2016 Jun; 87(6):063103. PubMed ID: 27370422
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of amino acid additives on the growth and physical properties of potassium acid phthalate (KAP) crystals.
    Kumaran AE; Kanchana P; Sekar C
    Spectrochim Acta A Mol Biomol Spectrosc; 2012 Jun; 91():370-4. PubMed ID: 22402478
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of divalent metal ion impurities (Ba²⁺, Ca²⁺ and Mg²⁺) on the growth, structural and physical properties of KAP crystals.
    Kanchana P; Elakkina Kumaran A; Hayakawa Y; Sekar C
    Spectrochim Acta A Mol Biomol Spectrosc; 2013 Feb; 103():187-92. PubMed ID: 23261612
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of trivalent metal ion impurities (Al3+, Cr3+ and Fe3+) on the growth, structural and physical properties of potassium acid phthalate (KAP) crystals.
    Kanchana P; Elakkina Kumaran A; Sekar C
    Spectrochim Acta A Mol Biomol Spectrosc; 2013 Aug; 112():21-6. PubMed ID: 23651775
    [TBL] [Abstract][Full Text] [Related]  

  • 12. X-Ray Crystal Spectroscopy of Sub-picosecond Laser-Produced Plasmas beyond 50 keV.
    Hölzer G; Förster E; Grätz M; Tillman C; Svanberg S
    J Xray Sci Technol; 1997 Jan; 7(1):50-70. PubMed ID: 21307539
    [TBL] [Abstract][Full Text] [Related]  

  • 13. High x-ray resolving power utilizing asymmetric diffraction from a quartz transmission crystal measured in the 6  keV to 22  keV energy range.
    Seely JF; Galtier E; Hudson LT; Henins A; Feldman U
    Appl Opt; 2019 Jul; 58(19):5225-5232. PubMed ID: 31503618
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Diagnosis of x-ray heated Mg/Fe opacity research plasmas.
    Bailey JE; Rochau GA; Mancini RC; Iglesias CA; MacFarlane JJ; Golovkin IE; Pain JC; Gilleron F; Blancard C; Cosse P; Faussurier G; Chandler GA; Nash TJ; Nielsen DS; Lake PW
    Rev Sci Instrum; 2008 Nov; 79(11):113104. PubMed ID: 19045886
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A high-resolution imaging x-ray crystal spectrometer for high energy density plasmas.
    Chen H; Bitter M; Hill KW; Kerr S; Magee E; Nagel SR; Park J; Schneider MB; Stone G; Williams GJ; Beiersdorfer P
    Rev Sci Instrum; 2014 Nov; 85(11):11E606. PubMed ID: 25430352
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range.
    Szabo CI; Feldman U; Seltzer S; Hudson LT; O'Brien M; Park HS; Seely JF
    Opt Lett; 2011 Apr; 36(8):1335-7. PubMed ID: 21499348
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spatially resolved high resolution x-ray spectroscopy for magnetically confined fusion plasmas (invited).
    Ince-Cushman A; Rice JE; Bitter M; Reinke ML; Hill KW; Gu MF; Eikenberry E; Broennimann Ch; Scott S; Podpaly Y; Lee SG; Marmar ES
    Rev Sci Instrum; 2008 Oct; 79(10):10E302. PubMed ID: 19044464
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A dual-channel, curved-crystal spectrograph for petawatt laser, x-ray backlighter source studies.
    Theobald W; Stoeckl C; Jaanimagi PA; Nilson PM; Storm M; Meyerhofer DD; Sangster TC; Hey D; MacKinnon AJ; Park HS; Patel PK; Shepherd R; Snavely RA; Key MH; King JA; Zhang B; Stephens RB; Akli KU; Highbarger K; Daskalova RL; Van Woerkom L; Freeman RR; Green JS; Gregori G; Lancaster K; Norreys PA
    Rev Sci Instrum; 2009 Aug; 80(8):083501. PubMed ID: 19725649
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Calibration of the OHREX high-resolution imaging crystal spectrometer at the Livermore electron beam ion traps.
    Hell N; Beiersdorfer P; Magee EW; Brown GV
    Rev Sci Instrum; 2016 Nov; 87(11):11D604. PubMed ID: 27910351
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Recent enhancements in the performance of the Orion high-resolution x-ray spectrometers.
    Hell N; Beiersdorfer P; Brown GV; Lockard TE; Magee EW; Shepherd R; Hoarty DJ; Brown CRD; Hill MP; Hobbs LMR; James SF; Lynch C; Caughey TA
    Rev Sci Instrum; 2021 Apr; 92(4):043507. PubMed ID: 34243402
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.