These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

280 related articles for article (PubMed ID: 25430268)

  • 1. Wide-angle ITER-prototype tangential infrared and visible viewing system for DIII-D.
    Lasnier CJ; Allen SL; Ellis RE; Fenstermacher ME; McLean AG; Meyer WH; Morris K; Seppala LG; Crabtree K; Van Zeeland MA
    Rev Sci Instrum; 2014 Nov; 85(11):11D855. PubMed ID: 25430268
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurements of spatial line emission profiles in the main scrape-off layer of the DIII-D tokamak.
    Groth M; Ellis RM; Brooks NH; Fenstermacher ME; Lasnier CJ; Meyer WH; Moeller JM
    Rev Sci Instrum; 2009 Mar; 80(3):033505. PubMed ID: 19334920
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optical design study of an infrared visible viewing system for Wendelstein 7-X divertor observation and control.
    Cantarini J; Hildebrandt D; König R; Klinkhamer F; Moddemeijer K; Vliegenthart W; Wolf R
    Rev Sci Instrum; 2008 Oct; 79(10):10F513. PubMed ID: 19044658
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Imaging divertor strike point splitting in RMP ELM suppression experiments in the DIII-D tokamak.
    Moyer RA; Bykov I; Orlov DM; Evans TE; Lee JS; Teklu AM; Fenstermacher ME; Makowski M; Lasnier CJ; Wang HQ; Watkins JG; Wu W
    Rev Sci Instrum; 2018 Oct; 89(10):10E106. PubMed ID: 30399795
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diagnostic options for radiative divertor feedback control on NSTX-U.
    Soukhanovskii VA; Gerhardt SP; Kaita R; McLean AG; Raman R
    Rev Sci Instrum; 2012 Oct; 83(10):10D716. PubMed ID: 23126890
    [TBL] [Abstract][Full Text] [Related]  

  • 6. CO2 laser polarimeter for Faraday rotation measurements in the DIII-D tokamak.
    Van Zeeland MA; Boivin RL; Carlstrom TN; Deterly TM
    Rev Sci Instrum; 2008 Oct; 79(10):10E719. PubMed ID: 19044536
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A dual-band adaptor for infrared imaging.
    McLean AG; Ahn JW; Maingi R; Gray TK; Roquemore AL
    Rev Sci Instrum; 2012 May; 83(5):053706. PubMed ID: 22667624
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Visible wide angle view imaging system of KTM tokamak based on multielement image fiber bundle.
    Chektybayev B; Shapovalov G; Kolodeshnikov A
    Rev Sci Instrum; 2015 May; 86(5):053505. PubMed ID: 26026523
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Concept development for the ITER equatorial port visible∕infrared wide angle viewing system.
    Reichle R; Beaumont B; Boilson D; Bouhamou R; Direz MF; Encheva A; Henderson M; Huxford R; Kazarian F; Lamalle P; Lisgo S; Mitteau R; Patel KM; Pitcher CS; Pitts RA; Prakash A; Raffray R; Schunke B; Snipes J; Diaz AS; Udintsev VS; Walker C; Walsh M
    Rev Sci Instrum; 2012 Oct; 83(10):10E520. PubMed ID: 23127027
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a mirror-based endoscope for divertor spectroscopy on JET with the new ITER-like wall (invited).
    Huber A; Brezinsek S; Mertens P; Schweer B; Sergienko G; Terra A; Arnoux G; Balshaw N; Clever M; Edlingdon T; Egner S; Farthing J; Hartl M; Horton L; Kampf D; Klammer J; Lambertz HT; Matthews GF; Morlock C; Murari A; Reindl M; Riccardo V; Samm U; Sanders S; Stamp M; Williams J; Zastrow KD; Zauner C;
    Rev Sci Instrum; 2012 Oct; 83(10):10D511. PubMed ID: 23130790
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of high-speed and wide-angle visible observation diagnostics on Experimental Advanced Superconducting Tokamak using catadioptric optics.
    Yang JH; Yang XF; Hu LQ; Zang Q; Han XF; Shao CQ; Sun TF; Chen H; Wang TF; Li FJ; Hu AL
    Rev Sci Instrum; 2013 Aug; 84(8):085102. PubMed ID: 24007102
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Extended fast-ion D-alpha diagnostic on DIII-D.
    Muscatello CM; Heidbrink WW; Taussig D; Burrell KH
    Rev Sci Instrum; 2010 Oct; 81(10):10D316. PubMed ID: 21033842
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Realization of a gas puff imaging system on the Wendelstein 7-X stellarator.
    Terry JL; von Stechow A; Baek SG; Ballinger SB; Grulke O; von Sehren C; Laube R; Killer C; Scharmer F; Brunner KJ; Knauer J; Bois S;
    Rev Sci Instrum; 2024 Sep; 95(9):. PubMed ID: 39254433
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Visible wide-angle view imaging system for the first plasma on the HL-2M tokamak.
    Liu L; He XF; Yu DL; Shi ZB; Lu J; Xia F; Zheng DL; Zhang N; He XX; Wei YL; Zang LG; Yang ZC; Yan LW; Liu Y; Yang QW
    Appl Opt; 2021 Apr; 60(11):3211-3216. PubMed ID: 33983221
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Progress of the ITER equatorial vis/IR wide angle viewing system optical design.
    Davi M; Corre Y; Guilhem D; Jullien F; Reichle R; Salasca S; Travère JM; de la Cal E; Manzanares A; de Pablos JL; Migozzi JB
    Rev Sci Instrum; 2008 Oct; 79(10):10F509. PubMed ID: 19044654
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Near-infrared spectroscopy for divertor plasma diagnosis and control in DIII-D tokamak.
    Soukhanovskii VA; McLean AG; Allen SL
    Rev Sci Instrum; 2014 Nov; 85(11):11E418. PubMed ID: 25430325
    [TBL] [Abstract][Full Text] [Related]  

  • 17. First measurements of a scintillator based fast-ion loss detector near the ASDEX Upgrade divertor.
    Gonzalez-Martin J; Ayllon-Guerola J; Garcia-Munoz M; Herrmann A; Leitenstern P; De Marne P; Zoletnik S; Kovacsik A; Galdon-Quiroga J; Rivero-Rodriguez J; Rodriguez-Ramos M; Sanchis-Sanchez L; Dominguez J; ;
    Rev Sci Instrum; 2018 Oct; 89(10):10I106. PubMed ID: 30399966
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Active spectroscopy measurements of the deuterium temperature, rotation, and density from the core to scrape off layer on the DIII-D tokamak (invited).
    Haskey SR; Grierson BA; Stagner L; Chrystal C; Ashourvan A; Bortolon A; Boyer MD; Burrell KH; Collins C; Groebner RJ; Kaplan DH; Pablant NA
    Rev Sci Instrum; 2018 Oct; 89(10):10D110. PubMed ID: 30399818
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Coherence imaging of scrape-off-layer and divertor impurity flows in the Mega Amp Spherical Tokamak (invited).
    Silburn SA; Harrison JR; Howard J; Gibson KJ; Meyer H; Michael CA; Sharples RM
    Rev Sci Instrum; 2014 Nov; 85(11):11D703. PubMed ID: 25430213
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modeling the response of a fast ion loss detector using orbit tracing techniques in a neutral beam prompt-loss study on the DIII-D tokamak.
    Pace DC; Fisher RK; García-Muñoz M; Darrow DS; Heidbrink WW; Muscatello CM; Nazikian R; Van Zeeland MA; Zhu YB
    Rev Sci Instrum; 2010 Oct; 81(10):10D305. PubMed ID: 21033831
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.