These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

245 related articles for article (PubMed ID: 25430280)

  • 1. A diamond based neutron spectrometer for diagnostics of deuterium-tritium fusion plasmas.
    Cazzaniga C; Nocente M; Rebai M; Tardocchi M; Calvani P; Croci G; Giacomelli L; Girolami M; Griesmayer E; Grosso G; Pillon M; Trucchi DM; Gorini G
    Rev Sci Instrum; 2014 Nov; 85(11):11E101. PubMed ID: 25430280
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Single crystal diamond detector measurements of deuterium-deuterium and deuterium-tritium neutrons in Joint European Torus fusion plasmas.
    Cazzaniga C; Sundén EA; Binda F; Croci G; Ericsson G; Giacomelli L; Gorini G; Griesmayer E; Grosso G; Kaveney G; Nocente M; Perelli Cippo E; Rebai M; Syme B; Tardocchi M;
    Rev Sci Instrum; 2014 Apr; 85(4):043506. PubMed ID: 24784606
    [TBL] [Abstract][Full Text] [Related]  

  • 3. First neutron spectroscopy measurements with a pixelated diamond detector at JET.
    Muraro A; Giacomelli L; Nocente M; Rebai M; Rigamonti D; Belli F; Calvani P; Figueiredo J; Girolami M; Gorini G; Grosso G; Murari A; Popovichev S; Trucchi DM; Tardocchi M;
    Rev Sci Instrum; 2016 Nov; 87(11):11D833. PubMed ID: 27910565
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detector Response to D-D Neutrons and Stability Measurements with 4H Silicon Carbide Detectors.
    Kushoro MH; Rebai M; Tardocchi M; Altana C; Cazzaniga C; De Marchi E; La Via F; Meda L; Meli A; Parisi M; Perelli Cippo E; Pillon M; Trotta A; Tudisco S; Gorini G
    Materials (Basel); 2021 Jan; 14(3):. PubMed ID: 33530362
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Response function of single crystal synthetic diamond detectors to 1-4 MeV neutrons for spectroscopy of D plasmas.
    Rebai M; Giacomelli L; Milocco A; Nocente M; Rigamonti D; Tardocchi M; Camera F; Cazzaniga C; Chen ZJ; Du TF; Fan TS; Giaz A; Hu ZM; Marchi T; Peng XY; Gorini G;
    Rev Sci Instrum; 2016 Nov; 87(11):11D823. PubMed ID: 27910604
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neutron emission spectroscopy of DT plasmas at enhanced energy resolution with diamond detectors.
    Giacomelli L; Nocente M; Rebai M; Rigamonti D; Milocco A; Tardocchi M; Chen ZJ; Du TF; Fan TS; Hu ZM; Peng XY; Hjalmarsson A; Gorini G;
    Rev Sci Instrum; 2016 Nov; 87(11):11D822. PubMed ID: 27910679
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Response of LaBr3(Ce) scintillators to 2.5 MeV fusion neutrons.
    Cazzaniga C; Nocente M; Tardocchi M; Croci G; Giacomelli L; Angelone M; Pillon M; Villari S; Weller A; Petrizzi L; Gorini G; ;
    Rev Sci Instrum; 2013 Dec; 84(12):123505. PubMed ID: 24393076
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thermal neutron dosimeter by synthetic single crystal diamond devices.
    Almaviva S; Marinelli M; Milani E; Prestopino G; Tucciarone A; Verona C; Verona-Rinati G; Angelone M; Pillon M
    Appl Radiat Isot; 2009 Jul; 67(7-8 Suppl):S183-5. PubMed ID: 19375336
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development and application of CVD diamond detectors to 14 MeV neutron flux monitoring.
    Angelone M; Pillon M; Marinelli M; Milani E; Paoletti A; Tucciarone A; Pucella G; Verona-Rinati G
    Radiat Prot Dosimetry; 2004; 110(1-4):233-6. PubMed ID: 15353651
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simultaneous measurement of energy spectrum and fluence of neutrons using a diamond detector.
    Liu J; Jiang H; Cui Z; Hu Y; Bai H; Fan T; Chen J; Gao Y; Yang X; Zhang G
    Sci Rep; 2022 Jul; 12(1):12022. PubMed ID: 35835805
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new tangential gamma-ray spectrometer for fast ion measurements in deuterium and deuterium-tritium plasmas of the Joint European Torus.
    Nocente M; Craciunescu T; Gorini G; Kiptily V; Tardocchi M; Braic V; Curuia M; Dal Molin A; Figueiredo J; Giacomelli L; Iliasova M; Kazakov Y; Khilkevitch E; Marcer G; Panontin E; Rigamonti D; Salewski M; Shevelev A; Soare S; Zoita V; Zychor I;
    Rev Sci Instrum; 2021 Apr; 92(4):043537. PubMed ID: 34243441
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of neutron spectrometer toward deuterium plasma diagnostics in LHD.
    Tomita H; Iwai H; Iguchi T; Isobe M; Kawarabayashi J; Konno C
    Rev Sci Instrum; 2010 Oct; 81(10):10D309. PubMed ID: 21033835
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A diamond 14 MeV neutron energy spectrometer with high energy resolution.
    Shimaoka T; Kaneko JH; Ochiai K; Tsubota M; Shimmyo H; Chayahara A; Umezawa H; Watanabe H; Shikata S; Isobe M; Osakabe M
    Rev Sci Instrum; 2016 Feb; 87(2):023503. PubMed ID: 26931845
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A high-resolution neutron spectroscopic camera for the SPARC tokamak based on the Jet European Torus deuterium-tritium experience.
    Tardocchi M; Rebai M; Rigamonti D; Tinguely RA; Caruggi F; Croci G; Dal Molin A; Ghani Z; Giacomelli L; Girolami M; Grosso G; Kushoro M; Marcer G; Mastellone M; Muraro A; Nocente M; Perelli Cippo E; Petruzzo M; Putignano O; Scionti J; Serpente V; Trucchi DM; Mackie S; Saltos AA; De Marchi E; Parisi M; Trotta A; de la Luna E; Garcia J; Kazakov Y; Maslov M; Stancar Z; Gorini G;
    Rev Sci Instrum; 2022 Nov; 93(11):113512. PubMed ID: 36461481
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Response measurement of single-crystal chemical vapor deposition diamond radiation detector for intense X-rays aiming at neutron bang-time and neutron burn-history measurement on an inertial confinement fusion with fast ignition.
    Shimaoka T; Kaneko JH; Arikawa Y; Isobe M; Sato Y; Tsubota M; Nagai T; Kojima S; Abe Y; Sakata S; Fujioka S; Nakai M; Shiraga H; Azechi H; Chayahara A; Umezawa H; Shikata S
    Rev Sci Instrum; 2015 May; 86(5):053503. PubMed ID: 26026521
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Tomographic analysis of neutron and gamma pulse shape distributions from liquid scintillation detectors at Joint European Torus.
    Giacomelli L; Conroy S; Gorini G; Horton L; Murari A; Popovichev S; Syme DB;
    Rev Sci Instrum; 2014 Feb; 85(2):023505. PubMed ID: 24593359
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Relationship between neutron yield rate of tokamak plasmas and spectrometer measured flux for different sight lines.
    Gorini G; Källne J; Ognissanto F; Tardocchi M
    Rev Sci Instrum; 2011 Mar; 82(3):033507. PubMed ID: 21456737
    [TBL] [Abstract][Full Text] [Related]  

  • 18. New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited).
    Murari A; Angelone M; Bonheure G; Cecil E; Craciunescu T; Darrow D; Edlington T; Ericsson G; Gatu-Johnson M; Gorini G; Hellesen C; Kiptily V; Mlynar J; Perez von Thun C; Pillon M; Popovichev S; Syme B; Tardocchi M; Zoita VL;
    Rev Sci Instrum; 2010 Oct; 81(10):10E136. PubMed ID: 21061488
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prospects for measuring the fuel ion ratio in burning ITER plasmas using a DT neutron emission spectrometer.
    Hellesen C; Skiba M; Dzysiuk N; Weiszflog M; Hjalmarsson A; Ericsson G; Conroy S; Andersson-Sundén E; Eriksson J; Binda F
    Rev Sci Instrum; 2014 Nov; 85(11):11D825. PubMed ID: 25430238
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Light output function and assembly of the time-of-flight enhanced diagnostics neutron spectrometer plastic scintillators for background reduction by double kinematic selection at EAST.
    Peng XY; Chen ZJ; Zhang X; Hu ZM; Du TF; Cui ZQ; Xie XF; Ge LJ; Yuan X; Gorini G; Nocente M; Tardocchi M; Hu LQ; Zhong GQ; Lin SY; Wan BN; Li XQ; Zhang GH; Chen JX; Fan TS
    Rev Sci Instrum; 2014 Nov; 85(11):11E112. PubMed ID: 25430291
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.