These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 25435384)

  • 1. Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test.
    Ramos Verri F; Santiago Junior JF; de Faria Almeida DA; de Oliveira GB; de Souza Batista VE; Marques Honório H; Noritomi PY; Pellizzer EP
    J Biomech; 2015 Jan; 48(1):138-45. PubMed ID: 25435384
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of crown-to-implant ratio on peri-implant stress: a finite element analysis.
    Verri FR; Batista VE; Santiago JF; Almeida DA; Pellizzer EP
    Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():234-40. PubMed ID: 25491825
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of increased crown height on stress distribution in short dental implant components and their surrounding bone: A finite element analysis.
    Bulaqi HA; Mousavi Mashhadi M; Safari H; Samandari MM; Geramipanah F
    J Prosthet Dent; 2015 Jun; 113(6):548-57. PubMed ID: 25794917
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A 3-D finite element study of the influence of crown-implant ratio on stress distribution.
    de Moraes SL; Verri FR; Santiago JF; Almeida DA; de Mello CC; Pellizzer EP
    Braz Dent J; 2013; 24(6):635-41. PubMed ID: 24474362
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-dimensional finite element analysis of stress distribution in retention screws of different crown-implant ratios.
    Moraes SL; Pellizzer EP; Verri FR; Santiago JF; Silva JV
    Comput Methods Biomech Biomed Engin; 2015; 18(7):689-96. PubMed ID: 23947571
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical Evaluation of Different Implant-Abutment Connections, Retention Systems, and Restorative Materials in the Implant-Supported Single Crowns Using 3D Finite Element Analysis.
    Lemos CAA; Verri FR; Noritomi PY; de Souza Batista VE; Cruz RS; de Luna Gomes JM; de Oliveira Limírio JPJ; Pellizzer EP
    J Oral Implantol; 2022 Jun; 48(3):194-201. PubMed ID: 34091686
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Finite element analysis of implant-supported prosthesis with pontic and cantilever in the posterior maxilla.
    de Souza Batista VE; Verri FR; Almeida DA; Santiago Junior JF; Lemos CA; Pellizzer EP
    Comput Methods Biomech Biomed Engin; 2017 May; 20(6):663-670. PubMed ID: 28349769
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of bicortical techniques in internal connection placed in premaxillary area by 3D finite element analysis.
    Verri FR; Cruz RS; Lemos CA; de Souza Batista VE; Almeida DA; Verri AC; Pellizzer EP
    Comput Methods Biomech Biomed Engin; 2017 Feb; 20(2):193-200. PubMed ID: 27409042
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of Different Heights of Prosthetic Crowns Supported by an Ultra-Short Implant Using Three-Dimensional Finite Element Analysis.
    Elias DM; Valerio CS; de Oliveira DD; Manzi FR; Zenóbio EG; Seraidarian PI
    Int J Prosthodont; 2020; 33(1):81-90. PubMed ID: 31860917
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of parafunctional loading and prosthetic connection on stress distribution: a 3D finite element analysis.
    Torcato LB; Pellizzer EP; Verri FR; Falcón-Antenucci RM; Santiago Júnior JF; de Faria Almeida DA
    J Prosthet Dent; 2015 Nov; 114(5):644-51. PubMed ID: 26187105
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of the parafunctional occlusal loading and crown height on stress distribution.
    Torcato LB; Pellizzer EP; Verri FR; Falcón-Antenucci RM; Batista VE; Lopes LF
    Braz Dent J; 2014; 25(6):554-60. PubMed ID: 25590205
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown.
    Sevimay M; Turhan F; Kiliçarslan MA; Eskitascioglu G
    J Prosthet Dent; 2005 Mar; 93(3):227-34. PubMed ID: 15775923
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-dimensional finite element analysis of vertical and angular misfit in implant-supported fixed prostheses.
    Assunção WG; Gomes EA; Rocha EP; Delben JA
    Int J Oral Maxillofac Implants; 2011; 26(4):788-96. PubMed ID: 21841989
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of Framework Type on the Biomechanical Behavior of Provisional Crowns: Strain Gauge and Finite Element Analyses.
    Tribst JPM; de Oliveira Dal Piva AM; Borges ALS; Nishioka RS; Bottino MA; Rodrigues VA
    Int J Periodontics Restorative Dent; 2020; 40(1):e9-e18. PubMed ID: 31815975
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of Offset Implant Placement on the Stress Distribution Around a Dental Implant: A Three-Dimensional Finite Element Analysis.
    Siadat H; Hashemzadeh S; Geramy A; Bassir SH; Alikhasi M
    J Oral Implantol; 2015 Dec; 41(6):646-51. PubMed ID: 24666333
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Platform switching: biomechanical evaluation using three-dimensional finite element analysis.
    Tabata LF; Rocha EP; Barão VA; Assunção WG
    Int J Oral Maxillofac Implants; 2011; 26(3):482-91. PubMed ID: 21691594
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retention System and Splinting on Morse Taper Implants in the Posterior Maxilla by 3D Finite Element Analysis.
    Lemos CAA; Verri FR; Santiago JF; Almeida DAF; Batista VES; Noritomi PY; Pellizzer DP
    Braz Dent J; 2018; 29(1):30-35. PubMed ID: 29267521
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of different implant designs on replacement of four teeth of the posterior free-end edentulism: Three-dimensional finite element analysis and clinic case validation.
    Ye Z; Ye H; Jiang Z; Wu S; Feng Z; Liu H; Wang X; Lan R; Lin X; Ding C; Zhang Q; Ding X; Wu L
    Ann Anat; 2023 Aug; 249():152111. PubMed ID: 37247761
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical Three-Dimensional Finite Element Analysis of Single Implant-Supported Prostheses in the Anterior Maxilla, with Different Surgical Techniques and Implant Types.
    Verri FR; Santiago JF; Almeida DA; de Souza Batista VE; Araujo Lemos CA; Mello CC; Pellizzer EP
    Int J Oral Maxillofac Implants; 2017; 32(4):e191-e198. PubMed ID: 28708909
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical analysis of different implant-abutments interfaces in different bone types: An in silico analysis.
    Pellizzer EP; Lemos CAA; Almeida DAF; de Souza Batista VE; Santiago Júnior JF; Verri FR
    Mater Sci Eng C Mater Biol Appl; 2018 Sep; 90():645-650. PubMed ID: 29853134
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.