164 related articles for article (PubMed ID: 25435456)
1. Enrichment of circulating tumor cells using a centrifugal affinity plate system.
Lee SW; Hyun KA; Kim SI; Kang JY; Jung HI
J Chromatogr A; 2014 Dec; 1373():25-30. PubMed ID: 25435456
[TBL] [Abstract][Full Text] [Related]
2. All-in-one centrifugal microfluidic device for size-selective circulating tumor cell isolation with high purity.
Lee A; Park J; Lim M; Sunkara V; Kim SY; Kim GH; Kim MH; Cho YK
Anal Chem; 2014 Nov; 86(22):11349-56. PubMed ID: 25317565
[TBL] [Abstract][Full Text] [Related]
3. Improved detection by ensemble-decision aliquot ranking of circulating tumor cells with low numbers of a targeted surface antigen.
Johnson ES; Anand RK; Chiu DT
Anal Chem; 2015 Sep; 87(18):9389-95. PubMed ID: 26302174
[TBL] [Abstract][Full Text] [Related]
4. EpCAM-independent capture of circulating tumor cells with a 'universal CTC-chip'.
Chikaishi Y; Yoneda K; Ohnaga T; Tanaka F
Oncol Rep; 2017 Jan; 37(1):77-82. PubMed ID: 27840987
[TBL] [Abstract][Full Text] [Related]
5. Optimization and Evaluation of a Novel Size Based Circulating Tumor Cell Isolation System.
Xu L; Mao X; Imrali A; Syed F; Mutsvangwa K; Berney D; Cathcart P; Hines J; Shamash J; Lu YJ
PLoS One; 2015; 10(9):e0138032. PubMed ID: 26397728
[TBL] [Abstract][Full Text] [Related]
6. Detection of EpCAM positive and negative circulating tumor cells in metastatic breast cancer patients.
Königsberg R; Obermayr E; Bises G; Pfeiler G; Gneist M; Wrba F; de Santis M; Zeillinger R; Hudec M; Dittrich C
Acta Oncol; 2011 Jun; 50(5):700-10. PubMed ID: 21261508
[TBL] [Abstract][Full Text] [Related]
7. Biotin-triggered decomposable immunomagnetic beads for capture and release of circulating tumor cells.
Lu NN; Xie M; Wang J; Lv SW; Yi JS; Dong WG; Huang WH
ACS Appl Mater Interfaces; 2015 Apr; 7(16):8817-26. PubMed ID: 25853336
[TBL] [Abstract][Full Text] [Related]
8. Negative enrichment of circulating tumor cells using a geometrically activated surface interaction chip.
Hyun KA; Lee TY; Jung HI
Anal Chem; 2013 May; 85(9):4439-45. PubMed ID: 23521012
[TBL] [Abstract][Full Text] [Related]
9. Spiral shape microfluidic channel for selective isolating of heterogenic circulating tumor cells.
Kwak B; Lee J; Lee J; Kim HS; Kang S; Lee Y
Biosens Bioelectron; 2018 Mar; 101():311-316. PubMed ID: 29055574
[TBL] [Abstract][Full Text] [Related]
10. Feasibility of a novel one-stop ISET device to capture CTCs and its clinical application.
Chen F; Wang S; Fang Y; Zheng L; Zhi X; Cheng B; Chen Y; Zhang C; Shi D; Song H; Cai C; Zhou P; Xiong B
Oncotarget; 2017 Jan; 8(2):3029-3041. PubMed ID: 27935872
[TBL] [Abstract][Full Text] [Related]
11. Cytometric characterization of circulating tumor cells captured by microfiltration and their correlation to the CellSearch(®) CTC test.
Adams DL; Stefansson S; Haudenschild C; Martin SS; Charpentier M; Chumsri S; Cristofanilli M; Tang CM; Alpaugh RK
Cytometry A; 2015 Feb; 87(2):137-44. PubMed ID: 25515318
[TBL] [Abstract][Full Text] [Related]
12. A novel method for downstream characterization of breast cancer circulating tumor cells following CellSearch isolation.
Frithiof H; Welinder C; Larsson AM; Rydén L; Aaltonen K
J Transl Med; 2015 Apr; 13():126. PubMed ID: 25896421
[TBL] [Abstract][Full Text] [Related]
13. Detection of circulating tumor cells in breast cancer may improve through enrichment with anti-CD146.
Mostert B; Kraan J; Bolt-de Vries J; van der Spoel P; Sieuwerts AM; Schutte M; Timmermans AM; Foekens R; Martens JW; Gratama JW; Foekens JA; Sleijfer S
Breast Cancer Res Treat; 2011 May; 127(1):33-41. PubMed ID: 20379845
[TBL] [Abstract][Full Text] [Related]
14. Detection of circulating tumor cells in prostate cancer based on carboxylated graphene oxide modified light addressable potentiometric sensor.
Gu Y; Ju C; Li Y; Shang Z; Wu Y; Jia Y; Niu Y
Biosens Bioelectron; 2015 Apr; 66():24-31. PubMed ID: 25460877
[TBL] [Abstract][Full Text] [Related]
15. Vita-Assay™ Method of Enrichment and Identification of Circulating Cancer Cells/Circulating Tumor Cells (CTCs).
Tulley S; Zhao Q; Dong H; Pearl ML; Chen WT
Methods Mol Biol; 2016; 1406():107-19. PubMed ID: 26820949
[TBL] [Abstract][Full Text] [Related]
16. Selective isolation of magnetic nanoparticle-mediated heterogeneity subpopulation of circulating tumor cells using magnetic gradient based microfluidic system.
Kwak B; Lee J; Lee D; Lee K; Kwon O; Kang S; Kim Y
Biosens Bioelectron; 2017 Feb; 88():153-158. PubMed ID: 27503409
[TBL] [Abstract][Full Text] [Related]
17. Two-stage microfluidic chip for selective isolation of circulating tumor cells (CTCs).
Hyun KA; Lee TY; Lee SH; Jung HI
Biosens Bioelectron; 2015 May; 67():86-92. PubMed ID: 25060749
[TBL] [Abstract][Full Text] [Related]
18. High-Throughput Isolation of Circulating Tumor Cells Using Cascaded Inertial Focusing Microfluidic Channel.
Abdulla A; Liu W; Gholamipour-Shirazi A; Sun J; Ding X
Anal Chem; 2018 Apr; 90(7):4397-4405. PubMed ID: 29537252
[TBL] [Abstract][Full Text] [Related]
19. Sensitive detection of viable circulating tumor cells using a novel conditionally telomerase-selective replicating adenovirus in non-small cell lung cancer patients.
Togo S; Katagiri N; Namba Y; Tulafu M; Nagahama K; Kadoya K; Takamochi K; Oh S; Suzuki K; Sakurai F; Mizuguchi H; Urata Y; Takahashi K
Oncotarget; 2017 May; 8(21):34884-34895. PubMed ID: 28432274
[TBL] [Abstract][Full Text] [Related]
20. Micropallet arrays for the capture, isolation and culture of circulating tumor cells from whole blood of mice engrafted with primary human pancreatic adenocarcinoma.
Gach PC; Attayek PJ; Whittlesey RL; Yeh JJ; Allbritton NL
Biosens Bioelectron; 2014 Apr; 54():476-83. PubMed ID: 24316450
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]