These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1296 related articles for article (PubMed ID: 25436913)

  • 21. Continuous Glucose Monitoring: A Review of Recent Studies Demonstrating Improved Glycemic Outcomes.
    Rodbard D
    Diabetes Technol Ther; 2017 Jun; 19(S3):S25-S37. PubMed ID: 28585879
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The effectiveness of continuous subcutaneous insulin pumps with continuous glucose monitoring in outpatient adolescents with type 1 diabetes: A systematic review.
    Matsuda E; Brennan P
    JBI Libr Syst Rev; 2012; 10(42 Suppl):1-10. PubMed ID: 27820140
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Type-1 Diabetes Patient Decision Simulator for In Silico Testing Safety and Effectiveness of Insulin Treatments.
    Vettoretti M; Facchinetti A; Sparacino G; Cobelli C
    IEEE Trans Biomed Eng; 2018 Jun; 65(6):1281-1290. PubMed ID: 28866479
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Long-Term Home Study on Nocturnal Hypoglycemic Alarms Using a New Fully Implantable Continuous Glucose Monitoring System in Type 1 Diabetes.
    Wang X; Ioacara S; DeHennis A
    Diabetes Technol Ther; 2015 Nov; 17(11):780-6. PubMed ID: 26177299
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Feasibility and Performance of Continuous Glucose Monitoring to Guide Computerized Insulin Infusion Therapy in Cardiovascular Intensive Care Unit.
    Ang L; Lin YK; Schroeder LF; Huang Y; DeGeorge CA; Arnold P; Akanbi F; Knotts S; DuBois E; Desbrough N; Qu Y; Freeman R; Esfandiari NH; Pop-Busui R; Gianchandani R
    J Diabetes Sci Technol; 2024 May; 18(3):562-569. PubMed ID: 38563491
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Randomized Evaluation of Glycemic Control in the Medical Intensive Care Unit Using Real-Time Continuous Glucose Monitoring (REGIMEN Trial).
    De Block CE; Gios J; Verheyen N; Manuel-y-Keenoy B; Rogiers P; Jorens PG; Scuffi C; Van Gaal LF
    Diabetes Technol Ther; 2015 Dec; 17(12):889-98. PubMed ID: 26305390
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Model of glucose sensor error components: identification and assessment for new Dexcom G4 generation devices.
    Facchinetti A; Del Favero S; Sparacino G; Cobelli C
    Med Biol Eng Comput; 2015 Dec; 53(12):1259-69. PubMed ID: 25416850
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluation of Accuracy of Six Blood Glucose Monitoring Systems and Modeling of Possibly Related Insulin Dosing Errors.
    Baumstark A; Jendrike N; Pleus S; Haug C; Freckmann G
    Diabetes Technol Ther; 2017 Oct; 19(10):580-588. PubMed ID: 28704063
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Taking a Closer Look--Continuous Glucose Monitoring in Non-Critically Ill Hospitalized Patients with Type 2 Diabetes Mellitus Under Basal-Bolus Insulin Therapy.
    Schaupp L; Donsa K; Neubauer KM; Mader JK; Aberer F; Höll B; Spat S; Augustin T; Beck P; Pieber TR; Plank J
    Diabetes Technol Ther; 2015 Sep; 17(9):611-8. PubMed ID: 25927357
    [TBL] [Abstract][Full Text] [Related]  

  • 30. An online failure detection method of the glucose sensor-insulin pump system: improved overnight safety of type-1 diabetic subjects.
    Facchinetti A; Del Favero S; Sparacino G; Cobelli C
    IEEE Trans Biomed Eng; 2013 Feb; 60(2):406-16. PubMed ID: 23193300
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Performance of Subcutaneous Continuous Glucose Monitoring in Adult Critically Ill Patients Receiving Vasopressor Therapy.
    Friman O; Soltani N; Lind M; Zetterqvist P; Balintescu A; Perner A; Oldner A; Rooyackers O; Mårtensson J
    Diabetes Technol Ther; 2024 Oct; 26(10):763-772. PubMed ID: 38758211
    [No Abstract]   [Full Text] [Related]  

  • 32. Sensitivity of the Predictive Hypoglycemia Minimizer System to the Algorithm Aggressiveness Factor.
    Finan DA; Dassau E; Breton MD; Patek SD; McCann TW; Kovatchev BP; Doyle FJ; Levy BL; Venugopalan R
    J Diabetes Sci Technol; 2015 Jun; 10(1):104-10. PubMed ID: 26134834
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Accuracy Evaluation of Four Blood Glucose Monitoring Systems in Unaltered Blood Samples in the Low Glycemic Range and Blood Samples in the Concentration Range Defined by ISO 15197.
    Freckmann G; Pleus S; Link M; Baumstark A; Schmid C; Högel J; Haug C
    Diabetes Technol Ther; 2015 Sep; 17(9):625-34. PubMed ID: 26062008
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Patient-reported outcomes for an integrated real-time continuous glucose monitoring/insulin pump system.
    Peyrot M; Rubin RR
    Diabetes Technol Ther; 2009 Jan; 11(1):57-62. PubMed ID: 19132857
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Simple Post-Processing of Continuous Glucose Monitoring Measurements Improves Endpoints in Clinical Trials.
    Jensen MH; Dethlefsen C; Hejlesen O; Vestergaard P
    J Diabetes Sci Technol; 2020 Nov; 14(6):1074-1078. PubMed ID: 31096765
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm.
    Bailey TS; Chang A; Christiansen M
    J Diabetes Sci Technol; 2015 Mar; 9(2):209-14. PubMed ID: 25370149
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Performance evaluation of three continuous glucose monitoring systems: comparison of six sensors per subject in parallel.
    Freckmann G; Pleus S; Link M; Zschornack E; Klötzer HM; Haug C
    J Diabetes Sci Technol; 2013 Jul; 7(4):842-53. PubMed ID: 23911165
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Vascular Glucose Sensor Symposium: Continuous Glucose Monitoring Systems (CGMS) for Hospitalized and Ambulatory Patients at Risk for Hyperglycemia, Hypoglycemia, and Glycemic Variability.
    Joseph JI; Torjman MC; Strasma PJ
    J Diabetes Sci Technol; 2015 Jul; 9(4):725-38. PubMed ID: 26078254
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment.
    Obermaier K; Schmelzeisen-Redeker G; Schoemaker M; Klötzer HM; Kirchsteiger H; Eikmeier H; del Re L
    J Diabetes Sci Technol; 2013 Jul; 7(4):824-32. PubMed ID: 23911163
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Insulin Sensitivity Index-Based Optimization of Insulin to Carbohydrate Ratio: In Silico Study Shows Efficacious Protection Against Hypoglycemic Events Caused by Suboptimal Therapy.
    Schiavon M; Dalla Man C; Cobelli C
    Diabetes Technol Ther; 2018 Feb; 20(2):98-105. PubMed ID: 29355438
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 65.