These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
191 related articles for article (PubMed ID: 25441883)
21. Determination of Cl, Br and I in granola: Development of an accurate analytical method using ICP-MS. Druzian GT; Nascimento MS; Cerqueira UMFM; Novaes CG; Bezerra MA; Duarte FA; Flores EMM Food Chem; 2021 May; 344():128677. PubMed ID: 33261993 [TBL] [Abstract][Full Text] [Related]
22. Electrothermal vaporization inductively coupled plasma atomic emission spectrometry determination of gold, palladium, and platinum using chelating resin YPA(4) as both extractant and chemical modifier. Wu Y; Jiang Z; Hu B; Duan J Talanta; 2004 Jun; 63(3):585-92. PubMed ID: 18969473 [TBL] [Abstract][Full Text] [Related]
23. Determination of platinum and rhodium in environmental matrixes by solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry. Vanhaecke F; Resano M; Pruneda-Lopez M; Moens L Anal Chem; 2002 Dec; 74(23):6040-8. PubMed ID: 12498200 [TBL] [Abstract][Full Text] [Related]
24. Hollow-fiber liquid-phase microextraction prior to low-temperature electrothermal vaporization ICP-MS for trace element analysis in environmental and biological samples. Xia L; Wu Y; Hu B J Mass Spectrom; 2007 Jun; 42(6):803-10. PubMed ID: 17511015 [TBL] [Abstract][Full Text] [Related]
25. Concentrations of chlorine, bromine and iodine in Japanese rivers. Tagami K; Uchida S Chemosphere; 2006 Dec; 65(11):2358-65. PubMed ID: 16777185 [TBL] [Abstract][Full Text] [Related]
26. Determination of Cu, As, Hg and Pb in vegetable oils by electrothermal vaporization inductively coupled plasma mass spectrometry with palladium nanoparticles as modifier. Hsu WH; Jiang SJ; Sahayam AC Talanta; 2013 Dec; 117():268-72. PubMed ID: 24209340 [TBL] [Abstract][Full Text] [Related]
27. Determination of Pd, Rh, Pt, Au in road dust by electrothermal vaporization inductively coupled plasma mass spectrometry with slurry sampling. Hsu WH; Jiang SJ; Sahayam AC Anal Chim Acta; 2013 Sep; 794():15-9. PubMed ID: 23972970 [TBL] [Abstract][Full Text] [Related]
28. Solid sampling ETV-ICPOES coupled to a nebulization/pre-evaporation system for direct elemental analysis of glutinous rice by external calibration with standard solutions. Sadiq N; Huang L; Kaveh F; Beauchemin D Food Chem; 2017 Dec; 237():1-6. PubMed ID: 28763942 [TBL] [Abstract][Full Text] [Related]
29. [Use of x-ray fluorescence analysis for determination of bromine in drug synthesis, with a look at chlorine (sulfur) and fluorine]. Sanner G; Usbeck H Pharmazie; 1985 Aug; 40(8):544-8. PubMed ID: 4080799 [TBL] [Abstract][Full Text] [Related]
30. Detection of bromine by ICP-oa-ToF-MS following photochemical vapor generation. Sturgeon RE Anal Chem; 2015 Mar; 87(5):3072-9. PubMed ID: 25649253 [TBL] [Abstract][Full Text] [Related]
31. Determination of Pt in biological samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) with electrothermal vaporization (ETV). Alimonti A; Petrucci F; Dominici C; Caroli S J Trace Elem Electrolytes Health Dis; 1987 Dec; 1(2):79-83. PubMed ID: 2856573 [TBL] [Abstract][Full Text] [Related]
32. Feasibility of ultra-trace determination of bromine and iodine in honey by ICP-MS using high sample mass in microwave-induced combustion. Costa VC; Picoloto RS; Hartwig CA; Mello PA; Flores EM; Mesko MF Anal Bioanal Chem; 2015 Oct; 407(26):7957-64. PubMed ID: 26310846 [TBL] [Abstract][Full Text] [Related]
33. Quantitative determination of bromine and iodine in food samples using ICP-MS. Nguyen TK; Ludwig R Anal Sci; 2014; 30(11):1089-92. PubMed ID: 25382046 [TBL] [Abstract][Full Text] [Related]
34. Feasibility of Rare Earth Element Determination in Low Concentration in Crude Oil: Direct Sampling Electrothermal Vaporization-Inductively Coupled Plasma Mass Spectrometry. Silva JS; Schneider Henn A; Dressler VL; Mello PA; Flores EMM Anal Chem; 2018 Jun; 90(11):7064-7071. PubMed ID: 29706063 [TBL] [Abstract][Full Text] [Related]
35. Phase transfer hollow fiber liquid phase microextraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of trace heavy metals in environmental and biological samples. Guo X; He M; Chen B; Hu B Talanta; 2012 Nov; 101():516-23. PubMed ID: 23158357 [TBL] [Abstract][Full Text] [Related]
36. Determination of refractory elements in atmospheric particulates using slurry sampling electrothermal vaporization inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry with polyvinylidene fluoride as chemical modifier. Zhang Y; Jiang Z; Hu B Rapid Commun Mass Spectrom; 2006; 20(14):2091-8. PubMed ID: 16773674 [TBL] [Abstract][Full Text] [Related]
37. Low-temperature electrothermal vaporization of thenoyltrifluoroacetone complex of Sc(III) and Y(III) for sample introduction in an inductively coupled plasma atomic emission spectrometry, and their determination in biological samples. Fan Z; Hu B; Jiang Z; Li S Anal Bioanal Chem; 2004 Jan; 378(2):456-9. PubMed ID: 14658024 [TBL] [Abstract][Full Text] [Related]
38. Slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for the determination of As and Se in soil and sludge. Tseng YJ; Liu CC; Jiang SJ Anal Chim Acta; 2007 Apr; 588(2):173-8. PubMed ID: 17386807 [TBL] [Abstract][Full Text] [Related]
39. Cloud point extraction combined with electrothermal vaporization inductively coupled plasma mass spectrometry for the speciation of inorganic selenium in environmental water samples. Chen B; Hu B; He M Rapid Commun Mass Spectrom; 2006; 20(19):2894-900. PubMed ID: 16941541 [TBL] [Abstract][Full Text] [Related]
40. [Direct determination of trace elements in human serum by electrothermal vaporization ICP-AES]. Chen SZ Guang Pu Xue Yu Guang Pu Fen Xi; 2004 Nov; 24(11):1441-3. PubMed ID: 15762499 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]