244 related articles for article (PubMed ID: 25441889)
21. Effect of energy per atom (E/n) on the Ar gas cluster ion beam (Ar-GCIB) and O
Wang SK; Chang HY; Chu YH; Kao WL; Wu CY; Lee YW; You YW; Chu KJ; Hung SH; Shyue JJ
Analyst; 2019 May; 144(10):3323-3333. PubMed ID: 30968864
[TBL] [Abstract][Full Text] [Related]
22. Depth profiling of peptide films with TOF-SIMS and a C60 probe.
Cheng J; Winograd N
Anal Chem; 2005 Jun; 77(11):3651-9. PubMed ID: 15924401
[TBL] [Abstract][Full Text] [Related]
23. Determination of lithium-ion distributions in nanostructured block polymer electrolyte thin films by X-ray photoelectron spectroscopy depth profiling.
Gilbert JB; Luo M; Shelton CK; Rubner MF; Cohen RE; Epps TH
ACS Nano; 2015 Jan; 9(1):512-20. PubMed ID: 25526511
[TBL] [Abstract][Full Text] [Related]
24. Enhanced surface sensitivity in secondary ion mass spectrometric analysis of organic thin films using size-selected Ar gas-cluster ion projectiles.
Tanaka M; Moritani K; Hirota T; Toyoda N; Yamada I; Inui N; Mochiji K
Rapid Commun Mass Spectrom; 2010 May; 24(10):1405-10. PubMed ID: 20411579
[TBL] [Abstract][Full Text] [Related]
25. Depth resolution at organic interfaces sputtered by argon gas cluster ions: the effect of energy, angle and cluster size.
Seah MP; Spencer SJ; Havelund R; Gilmore IS; Shard AG
Analyst; 2015 Oct; 140(19):6508-16. PubMed ID: 26325511
[TBL] [Abstract][Full Text] [Related]
26. Carbon-13 labeled polymers: an alternative tracer for depth profiling of polymer films and multilayers using secondary ion mass spectrometry.
Harton SE; Stevie FA; Zhu Z; Ade H
Anal Chem; 2006 May; 78(10):3452-60. PubMed ID: 16689549
[TBL] [Abstract][Full Text] [Related]
27. Impact energy dependence of SF5+-induced damage in poly(methyl methacrylate) studied using time-of-flight secondary ion mass spectrometry.
Wagner MS
Anal Chem; 2004 Mar; 76(5):1264-72. PubMed ID: 14987080
[TBL] [Abstract][Full Text] [Related]
28. X-ray photoelectron spectrometry depth profiling of organic thin films using C60 sputtering.
Chen YY; Yu BY; Wang WB; Hsu MF; Lin WC; Lin YC; Jou JH; Shyue JJ
Anal Chem; 2008 Jan; 80(2):501-5. PubMed ID: 18081326
[TBL] [Abstract][Full Text] [Related]
29. Determination of the sputtering yield of cholesterol using Arn(+) and C60(+(+)) cluster ions.
Rakowska PD; Seah MP; Vorng JL; Havelund R; Gilmore IS
Analyst; 2016 Aug; 141(16):4893-901. PubMed ID: 27299934
[TBL] [Abstract][Full Text] [Related]
30. Ambient low temperature plasma etching of polymer films for secondary ion mass spectrometry molecular depth profiling.
Muramoto S; Staymates ME; Brewer TM; Gillen G
Anal Chem; 2012 Dec; 84(24):10763-7. PubMed ID: 23137275
[TBL] [Abstract][Full Text] [Related]
31. Sample cooling or rotation improves C60 organic depth profiles of multilayered reference samples: results from a VAMAS interlaboratory study.
Sjövall P; Rading D; Ray S; Yang L; Shard AG
J Phys Chem B; 2010 Jan; 114(2):769-74. PubMed ID: 20020719
[TBL] [Abstract][Full Text] [Related]
32. Sputter-depth profiling for thin-film analysis.
Hofmann S
Philos Trans A Math Phys Eng Sci; 2004 Jan; 362(1814):55-75. PubMed ID: 15306276
[TBL] [Abstract][Full Text] [Related]
33. Molecular depth profiling of multilayer polymer films using time-of-flight secondary ion mass spectrometry.
Wagner MS
Anal Chem; 2005 Feb; 77(3):911-22. PubMed ID: 15679361
[TBL] [Abstract][Full Text] [Related]
34. Precise and fast secondary ion mass spectrometry depth profiling of polymer materials with large Ar cluster ion beams.
Ninomiya S; Ichiki K; Yamada H; Nakata Y; Seki T; Aoki T; Matsuo J
Rapid Commun Mass Spectrom; 2009 Jun; 23(11):1601-6. PubMed ID: 19399762
[TBL] [Abstract][Full Text] [Related]
35. Hybrid Perovskites Depth Profiling with Variable-Size Argon Clusters and Monatomic Ions Beams.
Noël C; Pescetelli S; Agresti A; Franquet A; Spampinato V; Felten A; di Carlo A; Houssiau L; Busby Y
Materials (Basel); 2019 Mar; 12(5):. PubMed ID: 30832309
[TBL] [Abstract][Full Text] [Related]
36. Argon cluster ion beams for organic depth profiling: results from a VAMAS interlaboratory study.
Shard AG; Havelund R; Seah MP; Spencer SJ; Gilmore IS; Winograd N; Mao D; Miyayama T; Niehuis E; Rading D; Moellers R
Anal Chem; 2012 Sep; 84(18):7865-73. PubMed ID: 22897795
[TBL] [Abstract][Full Text] [Related]
37. Protocols for three-dimensional molecular imaging using mass spectrometry.
Wucher A; Cheng J; Winograd N
Anal Chem; 2007 Aug; 79(15):5529-39. PubMed ID: 17583913
[TBL] [Abstract][Full Text] [Related]
38. Quantification problems in depth profiling of pwr steels using Ar+ ion sputtering and XPS analysis.
Ignatova VA; Van Den Berghe S; Van Dyck S; Popok VN
Microsc Microanal; 2006 Oct; 12(5):432-7. PubMed ID: 16984670
[TBL] [Abstract][Full Text] [Related]
39. XPS for non-destructive depth profiling and 3D imaging of surface nanostructures.
Hajati S; Tougaard S
Anal Bioanal Chem; 2010 Apr; 396(8):2741-55. PubMed ID: 20091159
[TBL] [Abstract][Full Text] [Related]
40. Partnering analytic models and dynamic secondary ion mass spectrometry simulations to interpret depth profiles due to kiloelectronvolt cluster bombardment.
Paruch RJ; Garrison BJ; Postawa Z
Anal Chem; 2012 Mar; 84(6):3010-6. PubMed ID: 22397617
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]