These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. An improved 191Os/191mIr generator using a hybrid anion exchanger. Packard AB; Day PJ; Treves ST Nucl Med Biol; 1995 Oct; 22(7):887-91. PubMed ID: 8547886 [TBL] [Abstract][Full Text] [Related]
5. Influence of pH adjustment agents on the biologic behavior of osmium-191 impurity in iridium-191m generator eluates. Weininger J; Issachar D; Lubin E; Zabari M; Trumper J J Nucl Med; 1990 Apr; 31(4):523-5. PubMed ID: 2109051 [TBL] [Abstract][Full Text] [Related]
6. A new osmium-191 leads to iridium-191m generator. Cheng C; Treves S; Samuel A; Davis MA J Nucl Med; 1980 Dec; 21(12):1169-76. PubMed ID: 7441355 [TBL] [Abstract][Full Text] [Related]
8. An improved 191Os-191mIr generator for radionuclide angiocardiography. Hnatowich DJ; Kulprathipanja S; Treves S Radiology; 1977 Apr; 123(1):189-94. PubMed ID: 403568 [TBL] [Abstract][Full Text] [Related]
9. Angiocardiography with iridium-191m: an ultrashort-lived radionuclide (T1/2 4.9 sec). Treves S; Kulprathipanja S; Hnatowich DJ Circulation; 1976 Aug; 54(2):275-9. PubMed ID: 820485 [TBL] [Abstract][Full Text] [Related]
10. Clinical usefulness of ultrashort-lived iridium-191m from a carbon-based generator system for the evaluation of the left ventricular function. Franken PR; Dobbeleir AA; Ham HR; Brihaye C; Guillaume M; Knapp FF; Vandevivere J J Nucl Med; 1989 Jun; 30(6):1025-31. PubMed ID: 2738684 [TBL] [Abstract][Full Text] [Related]
11. The development of an 191Os----191mIr generator using an osmium chelate parent complex--I. Trans-dioxobismalonatoosmate(VI). Packard AB; O'Brien GM; Treves S Int J Rad Appl Instrum B; 1986; 13(5):519-22. PubMed ID: 3818315 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of osmium(II)-nitrosyl complexes as a method to increase the yield of the 191Os-191mIr generator. Packard AB; Lambert C Int J Rad Appl Instrum B; 1992 Apr; 19(3):357-62. PubMed ID: 1629025 [TBL] [Abstract][Full Text] [Related]
14. Use of the Oak Ridge National Laboratory tungsten-188/rhenium-188 generator for preparation of the rhenium-188 HDD/lipiodol complex for trans-arterial liver cancer therapy. Jeong JM; Knapp FF Semin Nucl Med; 2008 Mar; 38(2):S19-29. PubMed ID: 18243839 [TBL] [Abstract][Full Text] [Related]
15. [191mIr: distribution and retention in animal experiments]. Kairemo KJ; Kestilä MS; Svahn RI; Hiltunen JV Nuklearmedizin; 1995 Jun; 34(3):115-7. PubMed ID: 7630744 [TBL] [Abstract][Full Text] [Related]
16. Iridium- 191 angiocardiography for the detection and quantitation of left-to-right shunting. Treves S; Cheng C; Samuel A; Lambrecht R; Babchyck B; Zimmerman R; Norwood W J Nucl Med; 1980 Dec; 21(12):1151-7. PubMed ID: 7192313 [TBL] [Abstract][Full Text] [Related]
17. Comparison of ultrashort-lived iridium-191m with technetium-99m for first pass radionuclide angiocardiographic evaluation of right and left ventricular function in adults. Heller GV; Treves ST; Parker JA; Duke LA; O'Brien GM; Davis RT; Fitzgibbon C; Packard AB J Am Coll Cardiol; 1986 Jun; 7(6):1295-302. PubMed ID: 3711486 [TBL] [Abstract][Full Text] [Related]
18. Development of a reliable Hg-195m--Au-195m generator for the production of Au-195m, a short-lived nuclide for vascular imaging. Brihaye C; Guillaume M; Lavi N; Cogneau M J Nucl Med; 1982 Dec; 23(12):1114-20. PubMed ID: 7143093 [TBL] [Abstract][Full Text] [Related]
19. Simple new method for effective concentration of 188Re solutions from alumina-based 188W-188Re generator. Guhlke S; Beets AL; Oetjen K; Mirzadeh S; Biersack HJ; Knapp FF J Nucl Med; 2000 Jul; 41(7):1271-8. PubMed ID: 10914921 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of two methods for concentrating perrhenate (188 Re) eluates obtained from 188 W-188 Re generator. Sarkar SK; Venkatesh M; Ramamoorthy N Appl Radiat Isot; 2009 Feb; 67(2):234-9. PubMed ID: 19056284 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]