475 related articles for article (PubMed ID: 25447004)
1. Double tension band wiring for treatment of olecranon fractures.
Kim W; Choi S; Yoon JO; Park HY; Kim SH; Kim JS
J Hand Surg Am; 2014 Dec; 39(12):2438-43. PubMed ID: 25447004
[TBL] [Abstract][Full Text] [Related]
2. The effect of Ding's screws and tension band wiring for treatment of olecranon fractures: a biomechanical study.
Zhao Y; Tian H; Yin N; Du L; Pan M; Ding L
Sci Rep; 2024 May; 14(1):9999. PubMed ID: 38693300
[TBL] [Abstract][Full Text] [Related]
3. Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures.
Kim JY; Lee YH; Gong HS; Lee SL; Lee SK; Baek GH
J Hand Surg Am; 2013 Sep; 38(9):1762-7. PubMed ID: 23849734
[TBL] [Abstract][Full Text] [Related]
4. Simple and comminuted displaced olecranon fractures: a clinical comparison between tension band wiring and plate fixation techniques.
Tarallo L; Mugnai R; Adani R; Capra F; Zambianchi F; Catani F
Arch Orthop Trauma Surg; 2014 Aug; 134(8):1107-14. PubMed ID: 24935660
[TBL] [Abstract][Full Text] [Related]
5. Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones.
Gruszka D; Arand C; Greenfield J; Nowak TE; Kuechle R; Kuhn S; Rommens PM
Arch Orthop Trauma Surg; 2017 Dec; 137(12):1651-1658. PubMed ID: 28864862
[TBL] [Abstract][Full Text] [Related]
6. Olecranon fracture fixation with a new implant: biomechanical and clinical considerations.
Koslowsky TC; Mader K; Dargel J; Schadt R; Koebke J; Pennig D
Injury; 2009 Jun; 40(6):618-24. PubMed ID: 19394014
[TBL] [Abstract][Full Text] [Related]
7. Outcome after olecranon fracture repair: Does construct type matter?
DelSole EM; Pean CA; Tejwani NC; Egol KA
Eur J Orthop Surg Traumatol; 2016 Feb; 26(2):153-9. PubMed ID: 26573486
[TBL] [Abstract][Full Text] [Related]
8. Comparison of tension band wiring and plate fixation in Mayo type 2A olecranon fractures.
Çağlar C; Akçaalan S; Özaslan Hİ; Yağar H; Uğurlu M
Jt Dis Relat Surg; 2021; 32(1):85-92. PubMed ID: 33463422
[TBL] [Abstract][Full Text] [Related]
9. Olecranon tension plating or olecranon tension band wiring? A comparative biomechanical study.
Gruszka D; Arand C; Nowak T; Dietz SO; Wagner D; Rommens P
Int Orthop; 2015 May; 39(5):955-60. PubMed ID: 25711396
[TBL] [Abstract][Full Text] [Related]
10. Modified tension band wiring technique for olecranon fractures: where and how should the K-wires be inserted to avoid articular penetration?
Özsoy MH; Kızılay O; Günenç C; Özsoy A; Demiryürek D; Hayran M; Erçakmak B; Sakaoğulları A
Acta Orthop Traumatol Turc; 2015; 49(2):190-6. PubMed ID: 26012941
[TBL] [Abstract][Full Text] [Related]
11. [Treatment of isolated fractures of the olecranon: percutaneous double-screw fixation versus conventional tension band wiring].
Uhlmann M; Barg A; Valderrabano V; Weber O; Wirtz DC; Pagenstert G
Unfallchirurg; 2014 Jul; 117(7):614-23. PubMed ID: 23754551
[TBL] [Abstract][Full Text] [Related]
12. WIRELESS TENSION BAND WIRING FOR OLECRANON FRACTURES. Case Series.
Roukoz S; Bayoud W
J Med Liban; 2016; 64(3):160-3. PubMed ID: 28850204
[TBL] [Abstract][Full Text] [Related]
13. Outcomes of displaced olecranon fractures treated with the Olecranon Sled.
Lovy AJ; Levy I; Keswani A; Rubin T; Hausman MR
J Shoulder Elbow Surg; 2018 Mar; 27(3):393-397. PubMed ID: 29195898
[TBL] [Abstract][Full Text] [Related]
14. Surgical interventions for treating fractures of the olecranon in adults.
Matar HE; Ali AA; Buckley S; Garlick NI; Atkinson HD
Cochrane Database Syst Rev; 2014 Nov; 2014(11):CD010144. PubMed ID: 25426876
[TBL] [Abstract][Full Text] [Related]
15. Comminuted Olecranon Fractures (Mayo IIB): Is Dynamic Tension Band Wiring Enough?
Esper GW; Herbosa CG; Moses MJ; Egol KA
J Orthop Trauma; 2023 Feb; 37(2):96-101. PubMed ID: 36658697
[TBL] [Abstract][Full Text] [Related]
16. Factors Affecting the Range of Motion of the Elbow after Open Reduction of Olecranon Fractures.
Fujihara Y; Ota H; Watanabe K
J Hand Surg Asian Pac Vol; 2021 Mar; 26(1):60-64. PubMed ID: 33559569
[No Abstract] [Full Text] [Related]
17. Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures.
Midtgaard KS; Søreide E; Brattgjerd JE; Moatshe G; Madsen JE; Flugsrud GB
J Shoulder Elbow Surg; 2020 Jun; 29(6):1242-1248. PubMed ID: 32139286
[TBL] [Abstract][Full Text] [Related]
18. Tension band wiring versus locking plate fixation for simple, two-part Mayo 2A olecranon fractures: a comparison of post-operative outcomes, complications, reoperations and economics.
Powell AJ; Farhan-Alanie OM; McGraw IWW
Musculoskelet Surg; 2019 Aug; 103(2):155-160. PubMed ID: 30006804
[TBL] [Abstract][Full Text] [Related]
19. Olecranon fractures: A biomechanical comparison of three tension band wiring fixation methods on bone models.
Calisal E; Uğur L
J Orthop Surg (Hong Kong); 2023; 31(3):10225536231223109. PubMed ID: 38115708
[TBL] [Abstract][Full Text] [Related]
20. The ideal implant for Mayo 2A olecranon fractures? An economic evaluation.
Tan BYJ; Pereira MJ; Ng J; Kwek EBK
J Shoulder Elbow Surg; 2020 Nov; 29(11):2347-2352. PubMed ID: 32569869
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]