BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 25450730)

  • 1. [Infusion of vasoactive drugs at low flow rate: effects of the syringe switch and syringe volume (experimental study)].
    Rakza T; Fily A; Mur S; Pennaforte T; Storme L
    Ann Fr Anesth Reanim; 2014 Nov; 33(11):572-5. PubMed ID: 25450730
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Warming of infusion syringes caused by electronic syringe pumps.
    Cornelius A; Frey B; Neff TA; Gerber AC; Weiss M
    Acta Anaesthesiol Scand; 2003 May; 47(5):549-53. PubMed ID: 12699511
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of syringe size on the performance of an infusion pump.
    Kim DW; Steward DJ
    Paediatr Anaesth; 1999; 9(4):335-7. PubMed ID: 10411770
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fluctuations in syringe-pump infusions: association with blood pressure variations in infants.
    Capes DF; Dunster KR; Sunderland VB; McMillan D; Colditz PB; McDonald C
    Am J Health Syst Pharm; 1995 Aug; 52(15):1646-53. PubMed ID: 7583827
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Syringe size and flow rate affect drug delivery from syringe pumps.
    Weiss M; Hug MI; Neff T; Fischer J
    Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fluid delivery from infusion-pump syringes.
    Carl JL; Erstad BL; Murphy JE; Slack MK
    Am J Health Syst Pharm; 1995 Jul; 52(13):1428-32. PubMed ID: 7671041
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [[The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems] ].
    Schulz G; Fischer J; Neff T; Bänziger O; Weiss M
    Anaesthesist; 2000 Dec; 49(12):1018-23. PubMed ID: 11202074
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Fluctuation of injection pressure of syringe pumps; the effect of syringe volumes and speed settings].
    Takahashi H; Okubo N; Naito H
    Masui; 1994 Jun; 43(6):905-11. PubMed ID: 8072151
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Syringe pumps for infusion of vasoactive drugs: mechanical idiosyncrasies and recommended operating procedures.
    Rooke GA; Bowdle TA
    Anesth Analg; 1994 Jan; 78(1):150-6. PubMed ID: 8267151
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps.
    Weiss M; Fischer J; Neff T; Baenziger O
    Anaesthesia; 2000 Nov; 55(11):1094-8. PubMed ID: 11069336
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantitative evaluation of the stability and delivery of interleukin-1B by infusion.
    Visor GC; Tsai KP; Duffy J; Miller MD; Calderwood T; Knepp VM
    J Parenter Sci Technol; 1990; 44(3):130-2. PubMed ID: 2370622
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of infusion line compliance on drug delivery rate during acute line loop formation.
    Weiss M; Bänziger O; Neff T; Fanconi S
    Intensive Care Med; 2000 Jun; 26(6):776-9. PubMed ID: 10945397
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Causes of failure and dangers in the use of motor driven infusion pumps. Accidental closure of the infusion system].
    Heise D; Rathgeber J; Kettler D
    Anaesthesist; 1998 Jan; 47(1):54-8. PubMed ID: 9530448
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The accuracy and variability of bolus injections with different sized syringes.
    Thobani SU; Steward DJ
    Can J Anaesth; 1992 Feb; 39(2):198-201. PubMed ID: 1544205
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Feasibility and optimization of the combined injection of contrast medium and normal saline with a single-syringe CT injection system].
    Raatschen HJ; Albrecht T
    Rofo; 2003 Jun; 175(6):844-8. PubMed ID: 12811699
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Downward movement of syringe pumps reduces syringe output.
    Kern H; Kuring A; Redlich U; Döpfmer UR; Sims NM; Spies CD; Kox WJ
    Br J Anaesth; 2001 Jun; 86(6):828-31. PubMed ID: 11573591
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Start-up delays of infusion syringe pumps.
    Neff T; Fischer J; Fehr S; Baenziger O; Weiss M
    Paediatr Anaesth; 2001; 11(5):561-5. PubMed ID: 11696120
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of a multiple-dose syringe pump system for intermittent i.v. drug delivery.
    Hola ET; Cronin CM; DeMonaco HJ; Franco ER; Pauley SY
    Am J Hosp Pharm; 1986 Oct; 43(10):2474-8. PubMed ID: 3788999
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Infusion phlebitis associated with a programmable syringe-pump system versus gravity-feed minibottles.
    Baptista RJ; Driscoll DF; Gallagher JA; O'Keefe E; Dumas GJ; Hammer SM; Pacella PP
    Clin Pharm; 1987 Apr; 6(4):314-8. PubMed ID: 3665384
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Clinical evaluation of a new programmable syringe infusion pump].
    Konishi R; Mitsuhata H; Saitoh K; Saitoh J; Hirabayashi Y; Fukuda H; Igarashi T; Hotta K; Shimizu R
    Masui; 1996 Aug; 45(8):1031-4. PubMed ID: 8818107
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.