These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

204 related articles for article (PubMed ID: 25452970)

  • 1. Intra-aortic balloon pump in coronary artery bypass graft - factors affecting outcome.
    Okonta K; Anbarasu M; Kanagarajan K
    J West Afr Coll Surg; 2011 Oct; 1(4):28-40. PubMed ID: 25452970
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of preoperative intra-aortic balloon pump on outcomes in coronary artery bypass grafting for unprotected left-main coronary artery disease.
    Daoulah A; Elmahrouk A; Arafat AA; Alzahrani B; Alshehri M; Qenawi W; Elganady A; Almahmeed W; Jamjoom A; Elmahrouk Y; Qutub MA; Dahdouh Z; Yousif N; Kanbr O; Hassan T; Chachar TS; Abohasan A; Alqahtani AM; Aldossari A; Ghani MA; Refaat W; Balghith M; Kazim HM; Abdulhabeeb IAM; Aithal J; Altnji I; Selim E; Hashmani S; Ibrahim AM; Abuelatta R; Ghonim AA; Shawky AM; Ahmad O; Alkaluf A; Hussien AF; Alama MN; Abualnaja S; Baqais RT; Alhassoun A; Elghaysha E; Al Wabisi SO; Algublan AN; Nasim N; Lotfi A
    Cardiovasc Diagn Ther; 2024 Jun; 14(3):340-351. PubMed ID: 38975005
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Preoperative intraaortic balloon pump enhances cardiac performance and improves the outcome of redo CABG.
    Christenson JT; Badel P; Simonet F; Schmuziger M
    Ann Thorac Surg; 1997 Nov; 64(5):1237-44. PubMed ID: 9386685
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Beneficial effect of preventative intra-aortic balloon pumping in high-risk patients undergoing first-time coronary artery bypass grafting-a single center experience.
    Gong Q; Xing J; Miao N; Zhao Y; Jia Z; Li J; Chen Y; Gao Q; Liu A; Sun Z; Liu X; Ji B
    Artif Organs; 2009 Aug; 33(8):587-92. PubMed ID: 19624583
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [A clinical study of preoperative prophylactic application of intra-aortic balloon pump in extreme high-risk patients undergoing coronary artery bypass grafting].
    Wang R; Chen X; Xu M; Jiang YS; Liu PS
    Zhonghua Wai Ke Za Zhi; 2013 Sep; 51(9):808-11. PubMed ID: 24330961
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of peri-operative intra-aortic balloon pump in patients undergoing coronary artery bypass grafting on outcomes in a resource limited setting.
    Sohail AA; Samejo A; Bajwa H; Wahab R; Asif N; Inam H; Shahabuddin S
    Perfusion; 2024 Oct; 39(7):1396-1404. PubMed ID: 37534589
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Single-centre experience with perioperative use of intraaortic balloon pump in cardiac surgery.
    Kucuker A; Cetin L; Kucuker SA; Gokcimen M; Hidiroglu M; Kunt A; Saglam F; Sener E
    Heart Lung Circ; 2014 May; 23(5):475-81. PubMed ID: 24345379
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of preoperative intra-aortic balloon pump support in high risk patients requiring myocardial revascularization.
    Christenson JT; Simonet F; Schmuziger M
    J Cardiovasc Surg (Torino); 1997 Aug; 38(4):397-402. PubMed ID: 9267351
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [The use of Intra Aortic Balloon Pump in Coronary Artery Bypass Graft Surgery].
    Gunnarsdóttir SLX; Gunnarsdóttir ELT; Heimisdottir AA; Heidarsdottir SR; Helgadottir S; Sigurdsson MI; Guðbjartsson T
    Laeknabladid; 2020 Feb; 106(2):63-70. PubMed ID: 32009623
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Outcomes after intra-aortic balloon pump insertion in cardiac surgery patients.
    Samanidis G; Georgiopoulos G; Bousounis S; Zoumpourlis P; Perreas K
    Rev Bras Ter Intensiva; 2020; 32(4):542-550. PubMed ID: 33470355
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Short-term outcomes of preoperative intra-aortic balloon pump use in patients undergoing adjunctive coronary endarterectomy: a retrospective observational study.
    Wang L; Hao X; Wang X; Gu C; Wang H; Hou X
    Perfusion; 2018 Sep; 33(6):426-432. PubMed ID: 29451075
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting.
    Field ML; Rengarajan A; Khan O; Spyt T; Richens D
    Cochrane Database Syst Rev; 2007 Jan; (1):CD004472. PubMed ID: 17253509
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preoperative intra-aortic counterpulsation in high-risk patients undergoing cardiac surgery: a meta-analysis of randomized controlled trials†.
    Pilarczyk K; Boening A; Jakob H; Langebartels G; Markewitz A; Haake N; Heringlake M; Trummer G
    Eur J Cardiothorac Surg; 2016 Jan; 49(1):5-17. PubMed ID: 26245629
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficacy of prophylactic intra-aortic balloon pump therapy in chronic heart failure patients undergoing cardiac surgery.
    Yildirim Y; Pecha S; Kubik M; Alassar Y; Deuse T; Hakmi S; Reichenspurner H
    Artif Organs; 2014 Nov; 38(11):967-72. PubMed ID: 24571119
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Frequency of intra-aortic balloon pump insertion and associated factors in coronary artery bypass Grafting in a tertiary care hospital.
    Ahmad I; Islam MU; Rehman MU; Khan B
    Pak J Med Sci; 2021; 37(2):393-397. PubMed ID: 33679920
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preoperative frontal QRS-T angle is an independent correlate of hospital length of stay and predictor of haemodynamic support requirement following off-pump coronary artery bypass graft surgery.
    Kaya E; Karabacak K; Kadan M; Gurses KM; Kocyigit D; Doganci S; Yildirim V; Demirkilic U
    Interact Cardiovasc Thorac Surg; 2015 Jul; 21(1):96-101. PubMed ID: 25911679
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An 11-year, single-institution analysis of intra-aortic balloon pump use in cardiac surgery.
    Zaky SS; Hanna AH; Sakr Esa WA; Xu M; Lober C; Sessler DI; Gonzalez-Stawinski G; Savage RM; Bashour CA
    J Cardiothorac Vasc Anesth; 2009 Aug; 23(4):479-83. PubMed ID: 19285430
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preventive use of intra-aortic balloon pump in patients undergoing high-risk coronary artery bypass grafting: a retrospective study.
    Zhang J; Lang Y; Guo L; Song X; Shu L; Su G; Liu H; Xu J
    Med Sci Monit; 2015 Mar; 21():855-60. PubMed ID: 25797193
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of preoperative intra-aortic balloon pump support in patients with coronary artery disease, poor left-ventricular function (LVEF < 40%), and hypertensive LV hypertrophy.
    Christenson JT; Simonet F; Badel P; Schmuziger M
    Thorac Cardiovasc Surg; 1997 Apr; 45(2):60-4. PubMed ID: 9175220
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Aggressive preoperative use of intraaortic balloon pump in elderly patients undergoing coronary artery bypass grafting.
    Gutfinger DE; Ott RA; Miller M; Selvan A; Codini MA; Alimadadian H; Tanner TM
    Ann Thorac Surg; 1999 Mar; 67(3):610-3. PubMed ID: 10215196
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.