2117 related articles for article (PubMed ID: 25457314)
1. Is it really necessary to restore radial anatomic parameters after distal radius fractures?
Dario P; Matteo G; Carolina C; Marco G; Cristina D; Daniele F; Andrea F
Injury; 2014 Dec; 45 Suppl 6():S21-6. PubMed ID: 25457314
[TBL] [Abstract][Full Text] [Related]
2. Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation.
Wright TW; Horodyski M; Smith DW
J Hand Surg Am; 2005 Mar; 30(2):289-99. PubMed ID: 15781351
[TBL] [Abstract][Full Text] [Related]
3. Orthogonal plating of intra-articular distal radius fractures with an associated radial column fracture via a single volar approach.
Helmerhorst GT; Kloen P
Injury; 2012 Aug; 43(8):1307-12. PubMed ID: 22648016
[TBL] [Abstract][Full Text] [Related]
4. Surgical treatment of unstable distal radius fractures with volar locking plates.
Murakami K; Abe Y; Takahashi K
J Orthop Sci; 2007 Mar; 12(2):134-40. PubMed ID: 17393268
[TBL] [Abstract][Full Text] [Related]
5. Volar fixed-angle plate osteosynthesis of unstable distal radius fractures: 12 months results.
Figl M; Weninger P; Liska M; Hofbauer M; Leixnering M
Arch Orthop Trauma Surg; 2009 May; 129(5):661-9. PubMed ID: 19225792
[TBL] [Abstract][Full Text] [Related]
6. Treatment of distal radial fractures with the DVR-A plate--the early Bristol experience.
Loveridge J; Ahearn N; Gee C; Pearson D; Sivaloganathan S; Bhatia R
Hand Surg; 2013; 18(2):159-67. PubMed ID: 24164118
[TBL] [Abstract][Full Text] [Related]
7. Prospective study of comminuted articular distal radius fractures stabilized by volar plating in the elderly.
Martinez-Mendez D; Lizaur-Utrilla A; de Juan-Herrero J
Int Orthop; 2018 Sep; 42(9):2243-2248. PubMed ID: 29626236
[TBL] [Abstract][Full Text] [Related]
8. Unstable distal radius fractures in the elderly patient--volar fixed-angle plate osteosynthesis prevents secondary loss of reduction.
Figl M; Weninger P; Jurkowitsch J; Hofbauer M; Schauer J; Leixnering M
J Trauma; 2010 Apr; 68(4):992-8. PubMed ID: 20065876
[TBL] [Abstract][Full Text] [Related]
9. Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures.
Perugia D; Guzzini M; Mazza D; Iorio C; Civitenga C; Ferretti A
Injury; 2017 Oct; 48 Suppl 3():S24-S29. PubMed ID: 29025605
[TBL] [Abstract][Full Text] [Related]
10. Intramedullary nail versus volar plate fixation of extra-articular distal radius fractures. Two year results of a prospective randomized trial.
Gradl G; Mielsch N; Wendt M; Falk S; Mittlmeier T; Gierer P; Gradl G
Injury; 2014 Jan; 45 Suppl 1():S3-8. PubMed ID: 24268189
[TBL] [Abstract][Full Text] [Related]
11. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius.
Rozental TD; Blazar PE
J Hand Surg Am; 2006 Mar; 31(3):359-65. PubMed ID: 16516728
[TBL] [Abstract][Full Text] [Related]
12. [Plate Osteosynthesis of Distal Ulna Fractures with Associated Distal Radius Fractures Treated by Open Reduction and Internal Fixation. Short-Term Functional and Radiographic Results].
Meluzinová P; Kopp L; Dráč P; Edelmann K; Obruba P
Acta Chir Orthop Traumatol Cech; 2015; 82(5):369-76. PubMed ID: 26516956
[TBL] [Abstract][Full Text] [Related]
13. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
[TBL] [Abstract][Full Text] [Related]
14. Fixed-angle volar plates in corrective osteotomies of malunions of dorsally angulated distal radius fractures.
Kiliç A; Kabukçuoğlu YS; Gül M; Sökücü S; Ozdoğan U
Acta Orthop Traumatol Turc; 2011; 45(5):297-303. PubMed ID: 22032994
[TBL] [Abstract][Full Text] [Related]
15. Radiographic outcomes of volar locked plating for distal radius fractures.
Mignemi ME; Byram IR; Wolfe CC; Fan KH; Koehler EA; Block JJ; Jordanov MI; Watson JT; Weikert DR; Lee DH
J Hand Surg Am; 2013 Jan; 38(1):40-8. PubMed ID: 23218558
[TBL] [Abstract][Full Text] [Related]
16. Prospective evaluation of distal radius fractures treated with variable-angle volar locking plates.
Fowler JR; Ilyas AM
J Hand Surg Am; 2013 Nov; 38(11):2198-203. PubMed ID: 24206983
[TBL] [Abstract][Full Text] [Related]
17. Volar plate versus k-wire fixation of distal radius fractures.
Brennan SA; Kiernan C; Beecher S; O'Reilly RT; Devitt BM; Kearns SR; O'Sullivan ME
Injury; 2016 Feb; 47(2):372-6. PubMed ID: 26592093
[TBL] [Abstract][Full Text] [Related]
18. Surgical correction of dorsally angulated distal radius malunions with fixed angle volar plating: a case series.
Malone KJ; Magnell TD; Freeman DC; Boyer MI; Placzek JD
J Hand Surg Am; 2006 Mar; 31(3):366-72. PubMed ID: 16516729
[TBL] [Abstract][Full Text] [Related]
19. Results of volar locking plating for unstable distal radius fractures.
Sügün TS; Gürbüz Y; Ozaksar K; Toros T; Kayalar M; Bal E
Acta Orthop Traumatol Turc; 2012; 46(1):22-5. PubMed ID: 22441447
[TBL] [Abstract][Full Text] [Related]
20. [Osteotomy after Distal Radius Fractures - Five-Year Clinical and Radiological Outcomes].
Cibula Z; Hrubina M; Melišík M; Mudrák I; Nečas L
Acta Chir Orthop Traumatol Cech; 2018; 85(4):254-260. PubMed ID: 30257755
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]