These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 25459245)

  • 21. Anterior surgery with insertion of titanium mesh cage and posterior instrumented fusion performed sequentially on the same day under one anesthesia for septic spondylitis of thoracolumbar spine: is the use of titanium mesh cages safe?
    Korovessis P; Petsinis G; Koureas G; Iliopoulos P; Zacharatos S
    Spine (Phila Pa 1976); 2006 Apr; 31(9):1014-9. PubMed ID: 16641778
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Follow-up of a new titaniumcoated polyetheretherketone cage for the cervical spine.
    Arregui R; Aso J; Martínez Quiñones JV; Sebastián C; Consolini F; Aso Vizan A
    Orthop Rev (Pavia); 2020 Apr; 12(1):8359. PubMed ID: 32391132
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Application of polyetheretherketone cages through minimally invasive oblique retroperitoneal approach for the treatment of lumbar polymicrobial spondylodiscitis: A STROBE-compliant retrospective study with 7 cases.
    Luo W; Zhu Y; Zhao ZH; Ou YS
    Medicine (Baltimore); 2020 Apr; 99(17):e18594. PubMed ID: 32332592
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Successful treatment of spondylodiscitis using titanium cages: a 3-year follow-up of 22 consecutive patients.
    Robinson Y; Tschoeke SK; Finke T; Kayser R; Ertel W; Heyde CE
    Acta Orthop; 2008 Oct; 79(5):660-4. PubMed ID: 18839373
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Surgical treatment of spondylodiscitis in the cervical spine: a minimum 2-year follow-up.
    Heyde CE; Boehm H; El Saghir H; Tschöke SK; Kayser R
    Eur Spine J; 2006 Sep; 15(9):1380-7. PubMed ID: 16868782
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Titanium (Ti) cages may be superior to polyetheretherketone (PEEK) cages in lumbar interbody fusion: a systematic review and meta-analysis of clinical and radiological outcomes of spinal interbody fusions using Ti versus PEEK cages.
    Tan JH; Cheong CK; Hey HWD
    Eur Spine J; 2021 May; 30(5):1285-1295. PubMed ID: 33555365
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The in vitro stabilising effect of polyetheretherketone cages versus a titanium cage of similar design for anterior lumbar interbody fusion.
    Spruit M; Falk RG; Beckmann L; Steffen T; Castelein RM
    Eur Spine J; 2005 Oct; 14(8):752-8. PubMed ID: 16133078
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Influence of instrumentation type on outcomes after surgical management of spondylodiscitis: a systematic review and meta-analysis.
    Maddy KS; Tigre JY; Lu VM; Costello MC; Errante EL; Levi AD; Burks SS
    Eur Spine J; 2024 Aug; 33(8):3175-3190. PubMed ID: 38148366
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Distractable titanium cages versus PEEK cages versus iliac crest bone grafts for the replacement of cervical vertebrae.
    König SA; Spetzger U
    Minim Invasive Ther Allied Technol; 2014 Mar; 23(2):102-5. PubMed ID: 24289173
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Vertebral Endplate Cyst as a Predictor of Nonunion After Lumbar Interbody Fusion: Comparison of Titanium and Polyetheretherketone Cages.
    Tanida S; Fujibayashi S; Otsuki B; Masamoto K; Takahashi Y; Nakayama T; Matsuda S
    Spine (Phila Pa 1976); 2016 Oct; 41(20):E1216-E1222. PubMed ID: 27054449
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Radiological and clinical outcomes in patients undergoing anterior cervical discectomy and fusion: Comparing titanium and PEEK (polyetheretherketone) cages.
    Junaid M; Rashid MU; Bukhari SS; Ahmed M
    Pak J Med Sci; 2018; 34(6):1412-1417. PubMed ID: 30559795
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparative effectiveness of PEEK rods versus titanium alloy rods in lumbar fusion: a preliminary report.
    Qi L; Li M; Zhang S; Xue J; Si H
    Acta Neurochir (Wien); 2013 Jul; 155(7):1187-93. PubMed ID: 23708088
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Surgical treatment of spondylodiscitis].
    Vcelák J; Tóth L
    Acta Chir Orthop Traumatol Cech; 2008 Apr; 75(2):110-6. PubMed ID: 18454915
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Is PEEK cage better than titanium cage in anterior cervical discectomy and fusion surgery? A meta-analysis.
    Li ZJ; Wang Y; Xu GJ; Tian P
    BMC Musculoskelet Disord; 2016 Sep; 17(1):379. PubMed ID: 27585553
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Posterior lumbar interbody fusion using rhBMP-2.
    Meisel HJ; Schnöring M; Hohaus C; Minkus Y; Beier A; Ganey T; Mansmann U
    Eur Spine J; 2008 Dec; 17(12):1735-44. PubMed ID: 18839225
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [The finite element analysis of polyetheretherketone/hydroxyapatite/carbon fiber cage].
    Liu X; Zhu H; Jing Y; Sui G; Zhang Z
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2013 Aug; 30(4):873-8. PubMed ID: 24059073
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Surgical treatment of cervical spondylodiscitis: a review of 30 consecutive patients.
    Shousha M; Boehm H
    Spine (Phila Pa 1976); 2012 Jan; 37(1):E30-6. PubMed ID: 21494200
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Treatment of vertebral osteomyelitis by radical debridement and stabilization using titanium mesh cages.
    Ruf M; Stoltze D; Merk HR; Ames M; Harms J
    Spine (Phila Pa 1976); 2007 Apr; 32(9):E275-80. PubMed ID: 17450059
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of Interbody Composition on the Development of Pseudarthrosis Following Anterior Cervical Discectomy and Fusion.
    D'Antonio N; Lambrechts MJ; Heard J; Bertiaume E; Toci G; Karamian B; Breyer G; Bodnar J; Canseco J; Hilibrand A; Schroeder G; Vaccaro AR; Kepler C
    Asian Spine J; 2023 Jun; 17(3):518-528. PubMed ID: 37160266
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation.
    Ponnappan RK; Serhan H; Zarda B; Patel R; Albert T; Vaccaro AR
    Spine J; 2009 Mar; 9(3):263-7. PubMed ID: 18838341
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.