These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 25459415)

  • 1. Pneumolabyrinth: An atypical complication in a cochlear implant.
    del Prado Venegas M; de Juan J; Orús C; de Juan M
    Acta Otorrinolaringol Esp; 2016; 67(2):114-6. PubMed ID: 25459415
    [No Abstract]   [Full Text] [Related]  

  • 2. Severe Vertigo After Cochlear Implantation: Acute Pneumolabyrinth.
    Karataş E; Toplu Y; Gündüz E; Demir İ
    Balkan Med J; 2018 Sep; 35(5):408-409. PubMed ID: 29769169
    [No Abstract]   [Full Text] [Related]  

  • 3. Pneumolabyrinth as an Early Computed Tomographic Finding After Cochlear Implantation and its Clinical Significance.
    Im SY; Kim MK; Lee S; Chung JH; Choi JW
    Otol Neurotol; 2022 Jan; 43(1):e38-e44. PubMed ID: 34726876
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Labyrinth dysfunction 8 months after cochlear implantation: a case report.
    Hempel JM; Jäger L; Baumann U; Krause E; Rasp G
    Otol Neurotol; 2004 Sep; 25(5):727-9. PubMed ID: 15354003
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Subcutaneous emphysema and pneumolabyrinth plus pneumocephalus as complications of middle ear implant and cochlear implant surgery.
    McKinnon BJ; Watts T
    Ear Nose Throat J; 2013 Jul; 92(7):298-300. PubMed ID: 23904304
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sound-induced vertigo after cochlear implantation.
    Coordes A; Basta D; Götze R; Scholz S; Seidl RO; Ernst A; Todt I
    Otol Neurotol; 2012 Apr; 33(3):335-42. PubMed ID: 22334157
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Incidence and quality of vertigo symptoms after cochlear implantation.
    Krause E; Louza JP; Wechtenbruch J; Hempel JM; Rader T; Gürkov R
    J Laryngol Otol; 2009 Mar; 123(3):278-82. PubMed ID: 18533053
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of cochlear implantation on horizontal semicircular canal function.
    Krause E; Louza JP; Hempel JM; Wechtenbruch J; Rader T; Gürkov R
    Eur Arch Otorhinolaryngol; 2009 Jun; 266(6):811-7. PubMed ID: 18807058
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impaired fixation suppression is a risk factor for vertigo after cochlear implantation.
    Krause E; Wechtenbruch J; Rader T; Berghaus A; Gürkov R
    J Laryngol Otol; 2009 Aug; 123(8):845-50. PubMed ID: 19243644
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Vestibular dysfunction after cochlear implant in adults].
    Holinski F; Elhajzein F; Scholz G; Sedlmaier B
    HNO; 2012 Oct; 60(10):880-5. PubMed ID: 22733278
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Late pneumolabyrinth after stapedectomy.
    Ziade G; Barake R; El Natout T; El Natout MA
    Eur Ann Otorhinolaryngol Head Neck Dis; 2016 Nov; 133(5):361-363. PubMed ID: 27318888
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intracochlear misdirected implantation of a cochlear implant.
    Tange RA; Grolman W; Maat A
    Acta Otolaryngol; 2006 Jun; 126(6):650-2. PubMed ID: 16720451
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pneumolabyrinth after cochlear implantation in large vestibular aqueduct syndrome.
    Ott IO; Schwab B; Becker H; Issing PR
    Otol Neurotol; 2008 Oct; 29(7):1037-8. PubMed ID: 18828208
    [No Abstract]   [Full Text] [Related]  

  • 14. Vestibular Function After Cochlear Implantation: A Comparison of Three Types of Electrodes.
    Frodlund J; Harder H; Mäki-Torkko E; Ledin T
    Otol Neurotol; 2016 Dec; 37(10):1535-1540. PubMed ID: 27749755
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transmastoid labyrinthectomy for disabling vertigo after cochlear implantation.
    Tutar H; Tutar VB; Gunduz B; Bayazit YA
    J Laryngol Otol; 2014 Nov; 128(11):1008-10. PubMed ID: 25204744
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pneumolabyrinth and positional vertigo after stapedectomy.
    Mandalà M; Colletti L; Carner M; Barillari M; Cerini R; Mucelli RP; Colletti V
    Auris Nasus Larynx; 2011 Aug; 38(4):547-50. PubMed ID: 21236609
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pneumolabyrinth as a computed tomographic finding in poststapedectomy vertigo.
    Isaacson JE; Laine F; Williams GH
    Ann Otol Rhinol Laryngol; 1995 Dec; 104(12):974-6. PubMed ID: 7492071
    [No Abstract]   [Full Text] [Related]  

  • 18. Medical or surgical complications related to the Nucleus multichannel cochlear implant.
    Cohen NL; Hoffman RA; Stroschein M
    Ann Otol Rhinol Laryngol Suppl; 1988; 135():8-13. PubMed ID: 3140706
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Rare Complication of Cochlear Implantation After Magnetic Resonance Imaging: Reversion of the Magnet.
    Öztürk E; Doruk C; Orhan KS; Çelik M; Polat B; Güldiken Y
    J Craniofac Surg; 2017 Jun; 28(4):e372-e374. PubMed ID: 28328611
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cochlear implant complications in 403 patients: comparative study of adults and children and review of the literature.
    Farinetti A; Ben Gharbia D; Mancini J; Roman S; Nicollas R; Triglia JM
    Eur Ann Otorhinolaryngol Head Neck Dis; 2014 Jun; 131(3):177-82. PubMed ID: 24889283
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.