60 related articles for article (PubMed ID: 25460861)
1. Effects of radiofrequency energy delivered through partially insulated metallic catheter tips on myocardial tissue heating and ablation lesion characteristics.
Nguyen DT; Moss JD; Zheng L; Huang J; Barham W; Sauer WH
Heart Rhythm; 2015 Mar; 12(3):623-630. PubMed ID: 25460861
[TBL] [Abstract][Full Text] [Related]
2. In Vivo Findings of a Novel Focal Ablation Catheter: Focused Electric Field Catheter Tip.
Huang HD; Melman P; Yavin H; Dye C; Melman Y
JACC Clin Electrophysiol; 2024 Apr; 10(4):762-767. PubMed ID: 38456859
[TBL] [Abstract][Full Text] [Related]
3. Safety verification of a novel irrigation catheter with flexible tip of laser-cut kerfs and contact force sensor.
Yamaguchi J; Takigawa M; Goya M; Yamamoto T; Ikenouchi T; Iwakawa H; Negishi M; Goto K; Shigeta T; Nishimura T; Takamiya T; Tao S; Miyazaki S; Sasano T
Pacing Clin Electrophysiol; 2023 Dec; 46(12):1536-1545. PubMed ID: 37957924
[TBL] [Abstract][Full Text] [Related]
4. Exploring the Full Potential of Radiofrequency Technology: A Practical Guide to Advanced Radiofrequency Ablation for Complex Ventricular Arrhythmias.
Tonko JB; Lambiase P
Curr Cardiol Rep; 2024 May; 26(5):269-282. PubMed ID: 38700597
[TBL] [Abstract][Full Text] [Related]
5. Ambient circulation surrounding an ablation catheter tip affects ablation lesion characteristics.
Nussinovitch U; Wang P; Babakhanian M; Narayan SM; Viswanathan M; Badhwar N; Zheng L; Sauer WH; Nguyen DT
J Cardiovasc Electrophysiol; 2023 Apr; 34(4):918-927. PubMed ID: 36852908
[TBL] [Abstract][Full Text] [Related]
6. Influence of the irrigation flow pattern and catheter tip design on the lesion formation: an ex vivo experimental model.
Kuroda M; Takeo A; Kobayashi H; Kuji R; Mori H; Tsutsui K; Fukunaga M; Nagashima M; Korai K; Ando K; Hiroshima K
J Interv Card Electrophysiol; 2024 Apr; 67(3):589-597. PubMed ID: 37691083
[TBL] [Abstract][Full Text] [Related]
7. Bipolar endo-epicardial RF ablation: Animal feasibility study.
Derejko P; Janus I; Kułakowski P; Kuśnierz J; Baran J; Hangiel U; Proszek J; Frydrychowski P; Michałek M; Noszczyk-Nowak A
Heart Rhythm; 2024 Jun; 21(6):790-798. PubMed ID: 38336196
[TBL] [Abstract][Full Text] [Related]
8. Radiofrequency lesion formation prediction with contact force versus local impedance.
Issa ZF
Curr Opin Cardiol; 2024 Jan; 39(1):6-14. PubMed ID: 37820074
[TBL] [Abstract][Full Text] [Related]
9. Native contrast visualization and tissue characterization of myocardial radiofrequency ablation and acetic acid chemoablation lesions at 0.55 T.
Kolandaivelu A; Bruce CG; Ramasawmy R; Yildirim DK; O'Brien KJ; Schenke WH; Rogers T; Campbell-Washburn AE; Lederman RJ; Herzka DA
J Cardiovasc Magn Reson; 2021 May; 23(1):50. PubMed ID: 33952312
[TBL] [Abstract][Full Text] [Related]
10. An in vivo comparison of radiofrequency cardiac lesions formed by standard and magnetically steered 4 mm tip catheters.
Thornton AS; De Castro CA; van Deel E; van Beusekom HM; Jordaens L
Neth Heart J; 2010 Feb; 18(2):66-71. PubMed ID: 20200611
[TBL] [Abstract][Full Text] [Related]
11. Sequential activation of a segmented ground pad reduces skin heating during radiofrequency tumor ablation: optimization via computational models.
Schutt DJ; Haemmerich D
IEEE Trans Biomed Eng; 2008 Jul; 55(7):1881-9. PubMed ID: 18595807
[TBL] [Abstract][Full Text] [Related]
12. Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapy.
Kim DH; Lu N; Ghaffari R; Kim YS; Lee SP; Xu L; Wu J; Kim RH; Song J; Liu Z; Viventi J; de Graff B; Elolampi B; Mansour M; Slepian MJ; Hwang S; Moss JD; Won SM; Huang Y; Litt B; Rogers JA
Nat Mater; 2011 Apr; 10(4):316-23. PubMed ID: 21378969
[TBL] [Abstract][Full Text] [Related]
13. Feasibility of a Novel
Joo MW; Jin S; Lee GJ; Lee YS; Chung YG
Clin Orthop Surg; 2024 Feb; 16(1):157-167. PubMed ID: 38304211
[TBL] [Abstract][Full Text] [Related]
14. "Honey pot"-like lesion formation: Impact of catheter contact angle on lesion formation by novel diamond-embedded temperature-controlled ablation catheter in a porcine experimental model.
Ogiso S; Fukaya H; Ogawa E; Mori H; Masuda Y; Yazaki Y; Murayama Y; Saito D; Kobayashi S; Nakamura H; Ishizue N; Kishihara J; Niwano S; Oikawa J; Ako J
Heart Rhythm; 2024 May; ():. PubMed ID: 38759918
[TBL] [Abstract][Full Text] [Related]
15. Thermal modeling of lesion growth with radiofrequency ablation devices.
Chang IA; Nguyen UD
Biomed Eng Online; 2004 Aug; 3(1):27. PubMed ID: 15298708
[TBL] [Abstract][Full Text] [Related]
16. Lesion modeling, characterization, and visualization for image-guided cardiac ablation therapy monitoring.
Linte CA; Camp JJ; Rettmann ME; Haemmerich D; Aktas MK; Huang DT; Packer DL; Holmes DR
J Med Imaging (Bellingham); 2018 Apr; 5(2):021218. PubMed ID: 29531966
[TBL] [Abstract][Full Text] [Related]
17. Editorial to "The effect of ablation settings on lesion characteristics with DiamondTemp ablation system: An ex vivo experiment".
Futyma P; Chen S
J Arrhythm; 2024 Apr; 40(2):228-229. PubMed ID: 38586836
[No Abstract] [Full Text] [Related]
18. Top 10 tips for performing cancer ablation.
Kachaamy T
Gastrointest Endosc; 2024 Mar; ():. PubMed ID: 38462056
[No Abstract] [Full Text] [Related]
19. Effect of Irrigant Characteristics on Lesion Formation After Radiofrequency Energy Delivery Using Ablation Catheters with Actively Cooled Tips.
Nguyen DT; Olson M; Zheng L; Barham W; Moss JD; Sauer WH
J Cardiovasc Electrophysiol; 2015 Jul; 26(7):792-8. PubMed ID: 25864402
[TBL] [Abstract][Full Text] [Related]
20.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
[Next] [New Search]