136 related articles for article (PubMed ID: 25463420)
21. [Experience in using a molecular resonance coagulator in neurooncology].
Cherekaev VA; Bekiashev AKh; Filippov IuA; Belov AI; Gol'bin DA
Zh Vopr Neirokhir Im N N Burdenko; 2005; (3):33-6. PubMed ID: 16485825
[TBL] [Abstract][Full Text] [Related]
22. Tissue thermal damage caused by bipolar forceps can be reduced with a combination of plastic and metal.
Remorgida V
Surg Endosc; 1998 Jul; 12(7):936-9. PubMed ID: 9632865
[TBL] [Abstract][Full Text] [Related]
23. A new bipolar suction-cautery forceps for micro-neurosurgical use.
Scarff TB
Surg Neurol; 1974 May; 2(3):213. PubMed ID: 4829036
[No Abstract] [Full Text] [Related]
24. Computerized bipolar diathermy with scissors and forceps in cutaneous surgery.
Stenquist BC; Holt PJ; Motley RJ
Dermatol Surg; 2002 Jul; 28(7):601-2. PubMed ID: 12135515
[TBL] [Abstract][Full Text] [Related]
25. Comparison of a new automatically controlled electrocoagulator (Valleylab NS 2000-INSTANT RESPONSE technology) with a high-frequency coagulator.
Lee JY; Ebel H; Balogh A; Lammers E; Klug N; Schröder R
Minim Invasive Neurosurg; 1999 Dec; 42(4):212-5. PubMed ID: 10667829
[TBL] [Abstract][Full Text] [Related]
26. Determination of the optimal technique for bipolar electrocoagulation treatment. An experimental evaluation of the BICAP and Gold probes.
Laine L
Gastroenterology; 1991 Jan; 100(1):107-12. PubMed ID: 1983812
[TBL] [Abstract][Full Text] [Related]
27. Modified malis bayonet forceps aids application of the cyberonics vagus nerve stimulator electrode: technical note.
Carey ME; Kutz S
Neurosurgery; 2000 Oct; 47(4):985-6; discussion 986-7. PubMed ID: 11014443
[TBL] [Abstract][Full Text] [Related]
28. [Temperature-controlled bipolar electrocoagulation].
Bühler K; Kato K; Klessen C; Koch R; Reich M; Winkler U; Schindler AE
Zentralbl Gynakol; 1991; 113(12):713-22. PubMed ID: 1833936
[TBL] [Abstract][Full Text] [Related]
29. Short-Burst Bipolar Coagulation for Repairing Partially Damaged Brain Arteries Preserving Their Flow: Technical Note.
Choque-Velasquez J; Colasanti R; Jahromi BR; Rafei A; Sharafeddin F; Hernesniemi J
World Neurosurg; 2016 Sep; 93():324-9. PubMed ID: 27312393
[TBL] [Abstract][Full Text] [Related]
30. Studies on coagulation and the development of an automatic computerized bipolar coagulator. Technical note.
Bergdahl B; Vällfors B
J Neurosurg; 1991 Jul; 75(1):148-51. PubMed ID: 2045902
[TBL] [Abstract][Full Text] [Related]
31. Infrared evaluation of the heat-sink bipolar diathermy dissection technique.
Allan J; Dusseldorp J; Rabey NG; Malata CM; Goltsman D; Phoon AF
J Plast Reconstr Aesthet Surg; 2015 Aug; 68(8):1145-51. PubMed ID: 26195271
[TBL] [Abstract][Full Text] [Related]
32. Functional and physical outcomes following use of a flexible CO2 laser fiber and bipolar electrocautery in close proximity to the rat sciatic nerve with correlation to an in vitro thermal profile model.
Robinson AM; Fishman AJ; Bendok BR; Richter CP
Biomed Res Int; 2015; 2015():280254. PubMed ID: 25699266
[TBL] [Abstract][Full Text] [Related]
33. A randomized comparison of a new flexible bipolar hemostasis forceps designed principally for NOTES versus a conventional surgical laparoscopic bipolar forceps for intra-abdominal vessel sealing in a porcine model.
Park PO; Long GL; Bergström M; Cunningham C; Vakharia OJ; Bakos GJ; Bally KR; Rothstein RI; Swain CP
Gastrointest Endosc; 2010 Apr; 71(4):835-41. PubMed ID: 19942215
[TBL] [Abstract][Full Text] [Related]
34. A new device for electrocoagulation of small vessels.
Casotto A; Piattelli M
Acta Neurochir (Wien); 1984; 71(1-2):151-60. PubMed ID: 6731057
[TBL] [Abstract][Full Text] [Related]
35. Reducing bipolar sterilization failures.
Soderstrom RM; Levy BS; Engel T
Obstet Gynecol; 1989 Jul; 74(1):60-3. PubMed ID: 2733944
[TBL] [Abstract][Full Text] [Related]
36. [Clinical experiences with a newly developed bipolar cutting and coagulation system (Malis CMC-III bipolar system)].
Niijima K; Yonekawa Y; Malis LI
No Shinkei Geka; 1994 Apr; 22(4):317-20. PubMed ID: 8164794
[No Abstract] [Full Text] [Related]
37. Surgical vein occlusion--comparison of four different methods in a rat model.
Schubert HM; Stuetz P; Hohlrieder M; Groesswang S; Moser TM; Glodny B; Petersen J; Haufe H; Zimmermann RF; Hager M
J Trauma; 2011 Sep; 71(3):E55-61. PubMed ID: 21336189
[TBL] [Abstract][Full Text] [Related]
38. Monopolar soft-mode coagulation using hemostatic forceps for peptic ulcer bleeding.
Yamasaki Y; Takenaka R; Nunoue T; Kono Y; Takemoto K; Taira A; Tsugeno H; Fujiki S
Hepatogastroenterology; 2014; 61(136):2272-6. PubMed ID: 25699366
[TBL] [Abstract][Full Text] [Related]
39. Two point coagulation: a follow-up report of a new technic and instrument for electrocoagulation in neurosurgery.
Greenwood J
Arch Phys Ther; 1942 Sep; 23(9):552-4. PubMed ID: 12336540
[TBL] [Abstract][Full Text] [Related]
40. Comparison of lateral thermal spread using monopolar and bipolar diathermy, and the bipolar vessel sealing system ThermoStapler™ during thyroidectomy.
Brzeziński J; Kałużna-Markowska K; Naze M; Stróżyk G; Dedecjus M
Pol Przegl Chir; 2011 Jul; 83(7):355-60. PubMed ID: 22166662
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]