BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 25467950)

  • 1. Slow cooling protocol improves fatigue life of zirconia crowns.
    Paula VG; Lorenzoni FC; Bonfante EA; Silva NR; Thompson VP; Bonfante G
    Dent Mater; 2015 Feb; 31(2):77-87. PubMed ID: 25467950
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Influence of veneering porcelain thickness and cooling rate on residual stresses in zirconia molar crowns.
    Al-Amleh B; Neil Waddell J; Lyons K; Swain MV
    Dent Mater; 2014 Mar; 30(3):271-80. PubMed ID: 24361198
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Thermal-induced residual stresses affect the lifetime of zirconia-veneer crowns.
    Belli R; Frankenberger R; Appelt A; Schmitt J; Baratieri LN; Greil P; Lohbauer U
    Dent Mater; 2013 Feb; 29(2):181-90. PubMed ID: 23261021
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of core thickness differences on post-fatigue indentation fracture resistance of veneered zirconia crowns.
    Alhasanyah A; Vaidyanathan TK; Flinton RJ
    J Prosthodont; 2013 Jul; 22(5):383-90. PubMed ID: 23387466
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lifetime prediction of zirconia and metal ceramic crowns loaded on marginal ridges.
    Fardin VP; de Paula VG; Bonfante EA; Coelho PG; Bonfante G
    Dent Mater; 2016 Dec; 32(12):1543-1554. PubMed ID: 27697333
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A photoelastic assessment of residual stresses in zirconia-veneer crowns.
    Belli R; Monteiro S; Baratieri LN; Katte H; Petschelt A; Lohbauer U
    J Dent Res; 2012 Mar; 91(3):316-20. PubMed ID: 22262632
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Conventional and modified veneered zirconia vs. metalloceramic: fatigue and finite element analysis.
    Silva NR; Bonfante E; Rafferty BT; Zavanelli RA; Martins LL; Rekow ED; Thompson VP; Coehlo PG
    J Prosthodont; 2012 Aug; 21(6):433-9. PubMed ID: 22672220
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Failure probability and stress distribution of milled porcelain-zirconia crowns with bioinspired/traditional design and graded interface.
    Ramos GF; Ramos NC; Alves LMM; Kaizer MR; Borges ALS; Campos TMB; Melo RM
    J Mech Behav Biomed Mater; 2021 Jul; 119():104438. PubMed ID: 33798936
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The fracture load and failure types of veneered anterior zirconia crowns: an analysis of normal and Weibull distribution of complete and censored data.
    Stawarczyk B; Ozcan M; Hämmerle CH; Roos M
    Dent Mater; 2012 May; 28(5):478-87. PubMed ID: 22196897
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of core design and veneering technique on damage and reliability of Y-TZP-supported crowns.
    Guess PC; Bonfante EA; Silva NR; Coelho PG; Thompson VP
    Dent Mater; 2013 Mar; 29(3):307-16. PubMed ID: 23228337
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Probability of survival of implant-supported metal ceramic and CAD/CAM resin nanoceramic crowns.
    Bonfante EA; Suzuki M; Lorenzoni FC; Sena LA; Hirata R; Bonfante G; Coelho PG
    Dent Mater; 2015 Aug; 31(8):e168-77. PubMed ID: 26074312
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of thermal distributions in veneered zirconia and metal restorations during firing.
    Benetti P; Kelly JR; Della Bona A
    Dent Mater; 2013 Nov; 29(11):1166-72. PubMed ID: 24075225
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Residual stresses in Y-TZP crowns due to changes in the thermal contraction coefficient of veneers.
    Meira JB; Reis BR; Tanaka CB; Ballester RY; Cesar PF; Versluis A; Swain MV
    Dent Mater; 2013 May; 29(5):594-601. PubMed ID: 23561942
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Residual stress of porcelain-fused to zirconia 3-unit fixed dental prostheses measured by nanoindentation.
    Fardin VP; Bonfante EA; Coelho PG; Janal MN; Tovar N; Witek L; Bordin D; Bonfante G
    Dent Mater; 2018 Feb; 34(2):260-271. PubMed ID: 29258696
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effect of various veneering techniques on mechanical strength of computer-controlled zirconia framework designs.
    Kanat B; Cömlekoğlu EM; Dündar-Çömlekoğlu M; Hakan Sen B; Ozcan M; Ali Güngör M
    J Prosthodont; 2014 Aug; 23(6):445-55. PubMed ID: 24417370
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of fatigue resistance and failure modes between metal-ceramic and all-ceramic crowns by cyclic loading in water.
    Nicolaisen MH; Bahrami G; Finlay S; Isidor F
    J Dent; 2014 Dec; 42(12):1613-20. PubMed ID: 25174946
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thermal gradients and residual stresses in veneered Y-TZP frameworks.
    Tholey MJ; Swain MV; Thiel N
    Dent Mater; 2011 Nov; 27(11):1102-10. PubMed ID: 21907400
    [TBL] [Abstract][Full Text] [Related]  

  • 18. High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings--a new fabrication mode for all-ceramic restorations.
    Beuer F; Schweiger J; Eichberger M; Kappert HF; Gernet W; Edelhoff D
    Dent Mater; 2009 Jan; 25(1):121-8. PubMed ID: 18620748
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fatigue behavior and damage modes of high performance poly-ether-ketone-ketone PEKK bilayered crowns.
    Alsadon O; Wood D; Patrick D; Pollington S
    J Mech Behav Biomed Mater; 2020 Oct; 110():103957. PubMed ID: 32957248
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization of residual stresses in zirconia veneered bilayers assessed via sharp and blunt indentation.
    Wendler M; Belli R; Petschelt A; Lohbauer U
    Dent Mater; 2015 Aug; 31(8):948-57. PubMed ID: 26037789
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.