These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 25470564)

  • 1. Anatomic relationship between the spermatic cord and the pubic tubercle: are our clamps injuring the cord during symphyseal repair?
    Collinge CA; Beltran MJ
    J Orthop Trauma; 2015 Jun; 29(6):290-4. PubMed ID: 25470564
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Anterior pelvic subcutaneous internal fixator application: an anatomic study.
    Moazzam C; Heddings AA; Moodie P; Cole PA
    J Orthop Trauma; 2012 May; 26(5):263-8. PubMed ID: 22337488
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Danger zone - The spermatic cord during anterior plating of the symphysis pubis.
    Hörlesberger N; Hohenberger G; Grechenig P; Schwarz A; Grechenig C; Ornig M; Tackner E; Gänsslen A
    Injury; 2022 Feb; 53(2):519-522. PubMed ID: 34620470
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A preliminary anatomical study on design of cannulated screw channels for fixation of symphysis pubis diastasis in small samples].
    Ma K; Zhu L; Fang Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Jan; 28(1):43-6. PubMed ID: 24693777
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Anatomical measurement and finite element study on screw channel parameter in percutaneous fixation of canulated screw for symphyseolysis.
    Yu K; Hong J; Sun Y; Shi C; Guo X; Zhou D
    Cell Biochem Biophys; 2015 Mar; 71(2):1243-8. PubMed ID: 25388836
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Minimally invasive anterior pelvic internal fixation: An anatomic study comparing Pelvic Bridge to INFIX.
    Reichel LM; MacCormick LM; Dugarte AJ; Rizkala AR; Graves SC; Cole PA
    Injury; 2018 Feb; 49(2):309-314. PubMed ID: 29277392
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Identifying safe corridors for anterior pelvic percutaneous instrumentation using computed tomography-based anatomical relationships.
    Green A; Feldman G; Moore DS; Ashikyan O; Sims GC; Sanders D; Starr A; Grewal I
    Injury; 2022 Oct; 53(10):3390-3393. PubMed ID: 35820984
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Treatment of old Tile B1 pelvic fracture by staged pelvic closure using external fixator combined with reconstruction plate].
    Tian Y; Fu Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Mar; 22(3):324-7. PubMed ID: 18396713
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The secondary external inguinal ring and associated fascial planes: surgical anatomy, embryology, applications.
    Mirilas P; Mentessidou A
    Hernia; 2013 Jun; 17(3):379-89. PubMed ID: 23404213
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Locked versus standard unlocked plating of the symphysis pubis in a Type-C pelvic injury: a cadaver biomechanical study.
    Moed BR; O'Boynick CP; Bledsoe JG
    Injury; 2014 Apr; 45(4):748-51. PubMed ID: 24326027
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Three-dimensionally-navigated cross-cannulated screw fixation for traumatic pubic symphysis diastasis: an anatomical study.
    Sun G; Yin C; Liu Z; Wang L; Mu W
    Acta Orthop Traumatol Turc; 2016; 50(2):214-21. PubMed ID: 26969958
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous iliosacral fixation in external rotational pelvic fractures. A biomechanical analysis.
    Giráldez-Sánchez MA; Lázaro-Gonzálvez Á; Martínez-Reina J; Serrano-Toledano D; Navarro-Robles A; Cano-Luis P; Fragkakis EM; Giannoudis PV
    Injury; 2015 Feb; 46(2):327-32. PubMed ID: 25554422
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Superior pubic ramus fractures fixed with percutaneous screws: what predicts fixation failure?
    Starr AJ; Nakatani T; Reinert CM; Cederberg K
    J Orthop Trauma; 2008 Feb; 22(2):81-7. PubMed ID: 18349774
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Safety Precautions for the Corona Mortis using Minimally Invasive Ilioinguinal Approach in Treatment of Anterior Pelvic Ring Fracture.
    Du MM; Wang AG; Shi XH; Zhao B; Liu M
    Orthop Surg; 2020 Jun; 12(3):957-963. PubMed ID: 32291959
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Risk of Spermatic Cord Injury During Anterior Pelvic Ring and Acetabular Surgery: An Anatomical Study.
    Firoozabadi R; Stafford P; Routt M
    Arch Bone Jt Surg; 2015 Oct; 3(4):269-73. PubMed ID: 26550592
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Anterior subcutaneous internal fixation of the pelvis - what rod-to-bone distance is anatomically optimal?
    Osterhoff G; Aichner EV; Scherer J; Simmen HP; Werner CML; Feigl GC
    Injury; 2017 Oct; 48(10):2162-2168. PubMed ID: 28859843
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Digital Anatomy to Improve Screw Insertion Techniques for Plate-Screw Fixation of the Pubic Body.
    Li W; Zhao F; Sun Z; Wang X; Gao S; Xu B; Mu W
    Biomed Res Int; 2018; 2018():4690879. PubMed ID: 30643807
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new method of spermatic cord mobilization in herniorrhaphy.
    Tan YH; Xiao YG; Du GN; Liu JW; Li M; Xu LX; Qiu WS
    Clin Anat; 2012 Nov; 25(8):1074-9. PubMed ID: 22308072
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Single cannulated screws for stabilisation of pelvic ring and acetabular fractures].
    Taller S; Lukáš R; Srám J
    Acta Chir Orthop Traumatol Cech; 2011; 78(6):568-77. PubMed ID: 22217412
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new modified pararectus approach and visualization: an anatomical study.
    Atlihan D; Aydin M; Capkin S; Surucu S; Gunaydin F; Acar HI
    Arch Orthop Trauma Surg; 2023 May; 143(5):2493-2501. PubMed ID: 35648218
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.