358 related articles for article (PubMed ID: 25471948)
1. Accuracy of surface registration compared to conventional volumetric registration in patient positioning for head-and-neck radiotherapy: a simulation study using patient data.
Kim Y; Li R; Na YH; Lee R; Xing L
Med Phys; 2014 Dec; 41(12):121701. PubMed ID: 25471948
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of the accuracy of a 3D surface imaging system for patient setup in head and neck cancer radiotherapy.
Gopan O; Wu Q
Int J Radiat Oncol Biol Phys; 2012 Oct; 84(2):547-52. PubMed ID: 22365627
[TBL] [Abstract][Full Text] [Related]
3. A novel surrogate to identify anatomical changes during radiotherapy of head and neck cancer patients.
Gros SA; Xu W; Roeske JC; Choi M; Emami B; Surucu M
Med Phys; 2017 Mar; 44(3):924-934. PubMed ID: 28019647
[TBL] [Abstract][Full Text] [Related]
4. A new markerless patient-to-image registration method using a portable 3D scanner.
Fan Y; Jiang D; Wang M; Song Z
Med Phys; 2014 Oct; 41(10):101910. PubMed ID: 25281962
[TBL] [Abstract][Full Text] [Related]
5. Characterization of a real-time surface image-guided stereotactic positioning system.
Peng JL; Kahler D; Li JG; Samant S; Yan G; Amdur R; Liu C
Med Phys; 2010 Oct; 37(10):5421-33. PubMed ID: 21089778
[TBL] [Abstract][Full Text] [Related]
6. Accuracy of low-dose proton CT image registration for pretreatment alignment verification in reference to planning proton CT.
Cassetta R; Piersimoni P; Riboldi M; Giacometti V; Bashkirov V; Baroni G; Ordonez C; Coutrakon G; Schulte R
J Appl Clin Med Phys; 2019 Apr; 20(4):83-90. PubMed ID: 30933433
[TBL] [Abstract][Full Text] [Related]
7. Cone beam CT imaging with limited angle of projections and prior knowledge for volumetric verification of non-coplanar beam radiation therapy: a proof of concept study.
Meng B; Xing L; Han B; Koong A; Chang D; Cheng J; Li R
Phys Med Biol; 2013 Nov; 58(21):7777-89. PubMed ID: 24140954
[TBL] [Abstract][Full Text] [Related]
8. Is ExacTrac x-ray system an alternative to CBCT for positioning patients with head and neck cancers?
Clemente S; Chiumento C; Fiorentino A; Simeon V; Cozzolino M; Oliviero C; Califano G; Caivano R; Fusco V
Med Phys; 2013 Nov; 40(11):111725. PubMed ID: 24320433
[TBL] [Abstract][Full Text] [Related]
9. Phantom validation of coregistration of PET and CT for image-guided radiotherapy.
Lavely WC; Scarfone C; Cevikalp H; Li R; Byrne DW; Cmelak AJ; Dawant B; Price RR; Hallahan DE; Fitzpatrick JM
Med Phys; 2004 May; 31(5):1083-92. PubMed ID: 15191296
[TBL] [Abstract][Full Text] [Related]
10. Improving superficial target delineation in radiation therapy with endoscopic tracking and registration.
Weersink RA; Qiu J; Hope AJ; Daly MJ; Cho BC; Dacosta RS; Sharpe MB; Breen SL; Chan H; Jaffray DA
Med Phys; 2011 Dec; 38(12):6458-68. PubMed ID: 22149829
[TBL] [Abstract][Full Text] [Related]
11. Image guidance during head-and-neck cancer radiation therapy: analysis of alignment trends with in-room cone-beam computed tomography scans.
Zumsteg Z; DeMarco J; Lee SP; Steinberg ML; Lin CS; McBride W; Lin K; Wang PC; Kupelian P; Lee P
Int J Radiat Oncol Biol Phys; 2012 Jun; 83(2):712-9. PubMed ID: 22099037
[TBL] [Abstract][Full Text] [Related]
12. Daily kV cone-beam CT and deformable image registration as a method for studying dosimetric consequences of anatomic changes in adaptive IMRT of head and neck cancer.
Elstrøm UV; Wysocka BA; Muren LP; Petersen JB; Grau C
Acta Oncol; 2010 Oct; 49(7):1101-8. PubMed ID: 20831502
[TBL] [Abstract][Full Text] [Related]
13. Towards clinical implementation of ultrafast combined kV-MV CBCT for IGRT of lung cancer : Evaluation of registration accuracy based on phantom study.
Arns A; Blessing M; Fleckenstein J; Stsepankou D; Boda-Heggemann J; Simeonova-Chergou A; Hesser J; Lohr F; Wenz F; Wertz H
Strahlenther Onkol; 2016 May; 192(5):312-21. PubMed ID: 26864049
[TBL] [Abstract][Full Text] [Related]
14. Integration of optical imaging with a small animal irradiator.
Weersink RA; Ansell S; Wang A; Wilson G; Shah D; Lindsay PE; Jaffray DA
Med Phys; 2014 Oct; 41(10):102701. PubMed ID: 25281980
[TBL] [Abstract][Full Text] [Related]
15. Motion monitoring for cranial frameless stereotactic radiosurgery using video-based three-dimensional optical surface imaging.
Li G; Ballangrud A; Kuo LC; Kang H; Kirov A; Lovelock M; Yamada Y; Mechalakos J; Amols H
Med Phys; 2011 Jul; 38(7):3981-94. PubMed ID: 21858995
[TBL] [Abstract][Full Text] [Related]
16. Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for "dose of the day" calculations.
Veiga C; McClelland J; Moinuddin S; Lourenço A; Ricketts K; Annkah J; Modat M; Ourselin S; D'Souza D; Royle G
Med Phys; 2014 Mar; 41(3):031703. PubMed ID: 24593707
[TBL] [Abstract][Full Text] [Related]
17. Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT.
Rampado O; Giglioli FR; Rossetti V; Fiandra C; Ragona R; Ropolo R
Med Phys; 2016 May; 43(5):2515. PubMed ID: 27147362
[TBL] [Abstract][Full Text] [Related]
18. A 3D global-to-local deformable mesh model based registration and anatomy-constrained segmentation method for image guided prostate radiotherapy.
Zhou J; Kim S; Jabbour S; Goyal S; Haffty B; Chen T; Levinson L; Metaxas D; Yue NJ
Med Phys; 2010 Mar; 37(3):1298-308. PubMed ID: 20384267
[TBL] [Abstract][Full Text] [Related]
19. Set-up errors and planning margins in planar and CBCT image-guided radiotherapy using three different imaging systems: A clinical study for prostate and head-and-neck cancer.
Dzierma Y; Beyhs M; Palm J; Niewald M; Bell K; Nuesken F; Licht N; Rübe C
Phys Med; 2015 Dec; 31(8):1055-1059. PubMed ID: 26476789
[TBL] [Abstract][Full Text] [Related]
20. Fast time-of-flight camera based surface registration for radiotherapy patient positioning.
Placht S; Stancanello J; Schaller C; Balda M; Angelopoulou E
Med Phys; 2012 Jan; 39(1):4-17. PubMed ID: 22225270
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]