102 related articles for article (PubMed ID: 25474807)
1. Apparent Ultra-High b-Value Diffusion-Weighted Image Reconstruction via Hidden Conditional Random Fields.
Shafiee MJ; Haider SA; Wong A; Lui D; Cameron A; Modhafar A; Fieguth P; Haider MA
IEEE Trans Med Imaging; 2015 May; 34(5):1111-24. PubMed ID: 25474807
[TBL] [Abstract][Full Text] [Related]
2. Noise-Compensated, Bias-Corrected Diffusion Weighted Endorectal Magnetic Resonance Imaging via a Stochastically Fully-Connected Joint Conditional Random Field Model.
Boroomand A; Shafiee MJ; Khalvati F; Haider MA; Wong A
IEEE Trans Med Imaging; 2016 Dec; 35(12):2587-2597. PubMed ID: 27392347
[TBL] [Abstract][Full Text] [Related]
3. High and ultra-high b-value diffusion-weighted imaging in prostate cancer: a quantitative analysis.
Wetter A; Nensa F; Lipponer C; Guberina N; Olbricht T; Schenck M; Schlosser TW; Gratz M; Lauenstein TC
Acta Radiol; 2015 Aug; 56(8):1009-15. PubMed ID: 25168023
[TBL] [Abstract][Full Text] [Related]
4. Diffusion-weighted imaging of the prostate: Comparison of b1000 and b2000 image sets for index lesion detection.
Rosenkrantz AB; Hindman N; Lim RP; Das K; Babb JS; Mussi TC; Taneja SS
J Magn Reson Imaging; 2013 Sep; 38(3):694-700. PubMed ID: 23371846
[TBL] [Abstract][Full Text] [Related]
5. Monte Carlo bias field correction in endorectal diffusion imaging.
Lui D; Modhafar A; Glaister J; Wong A; Haider MA
IEEE Trans Biomed Eng; 2014 Feb; 61(2):368-80. PubMed ID: 24448596
[TBL] [Abstract][Full Text] [Related]
6. Comparison of apparent diffusion coefficient calculation between two-point and multipoint B value analyses in prostate cancer and benign prostate tissue at 3 T: preliminary experience.
Park SY; Kim CK; Park BK; Kwon GY
AJR Am J Roentgenol; 2014 Sep; 203(3):W287-94. PubMed ID: 25148186
[TBL] [Abstract][Full Text] [Related]
7. Optimization of b-value distribution for four mathematical models of prostate cancer diffusion-weighted imaging using b values up to 2000 s/mm(2): simulation and repeatability study.
Merisaari H; Jambor I
Magn Reson Med; 2015 May; 73(5):1954-69. PubMed ID: 25045885
[TBL] [Abstract][Full Text] [Related]
8. High-b-value diffusion-weighted MRI for the detection of prostate cancer at 3 T.
Wang X; Qian Y; Liu B; Cao L; Fan Y; Zhang JJ; Yu Y
Clin Radiol; 2014 Nov; 69(11):1165-70. PubMed ID: 25182363
[TBL] [Abstract][Full Text] [Related]
9. Diffusion-weighted imaging in the prostate: an apparent diffusion coefficient comparison of half-Fourier acquisition single-shot turbo spin-echo and echo planar imaging.
Babourina-Brooks B; Cowin GJ; Wang D
Magn Reson Imaging; 2012 Feb; 30(2):189-94. PubMed ID: 22055748
[TBL] [Abstract][Full Text] [Related]
10. Differentiation of central gland prostate cancer from benign prostatic hyperplasia using monoexponential and biexponential diffusion-weighted imaging.
Liu X; Zhou L; Peng W; Wang C; Wang H
Magn Reson Imaging; 2013 Oct; 31(8):1318-24. PubMed ID: 23791546
[TBL] [Abstract][Full Text] [Related]
11. Quantitative investigative analysis of tumour separability in the prostate gland using ultra-high b-value computed diffusion imaging.
Glaister J; Cameron A; Wong A; Haider MA
Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():420-3. PubMed ID: 23365918
[TBL] [Abstract][Full Text] [Related]
12. Sparse reconstruction of compressive sensing MRI using cross-domain stochastically fully connected conditional random fields.
Li E; Khalvati F; Shafiee MJ; Haider MA; Wong A
BMC Med Imaging; 2016 Aug; 16(1):51. PubMed ID: 27566536
[TBL] [Abstract][Full Text] [Related]
13. Quantitative evaluation of computed high B value diffusion-weighted magnetic resonance imaging of the prostate.
Maas MC; Fütterer JJ; Scheenen TW
Invest Radiol; 2013 Nov; 48(11):779-86. PubMed ID: 23907102
[TBL] [Abstract][Full Text] [Related]
14. In vivo measurement of the apparent diffusion coefficient in normal and malignant prostatic tissue using thin-slice echo-planar imaging.
Manenti G; Squillaci E; Di Roma M; Carlani M; Mancino S; Simonetti G
Radiol Med; 2006 Dec; 111(8):1124-33. PubMed ID: 17171522
[TBL] [Abstract][Full Text] [Related]
15. Impact of measurement parameters on apparent diffusion coefficient quantification in diffusion-weighted-magnetic resonance imaging.
Schmidt H; Gatidis S; Schwenzer NF; Martirosian P
Invest Radiol; 2015 Jan; 50(1):46-56. PubMed ID: 25247326
[TBL] [Abstract][Full Text] [Related]
16. High-resolution diffusion-weighted imaging of the prostate.
Medved M; Soylu-Boy FN; Karademir I; Sethi I; Yousuf A; Karczmar GS; Oto A
AJR Am J Roentgenol; 2014 Jul; 203(1):85-90. PubMed ID: 24951199
[TBL] [Abstract][Full Text] [Related]
17. High b-value diffusion-weighted MR imaging of normal brain at 3T.
Cihangiroglu M; Uluğ AM; Firat Z; Bayram A; Kovanlikaya A; Kovanlikaya I
Eur J Radiol; 2009 Mar; 69(3):454-8. PubMed ID: 18162352
[TBL] [Abstract][Full Text] [Related]
18. High resolution diffusion weighted magnetic resonance imaging of the pancreas using reduced field of view single-shot echo-planar imaging at 3 T.
Ma C; Li YJ; Pan CS; Wang H; Wang J; Chen SY; Lu JP
Magn Reson Imaging; 2014 Feb; 32(2):125-31. PubMed ID: 24231348
[TBL] [Abstract][Full Text] [Related]
19. Clinical utility of apparent diffusion coefficient values obtained using high b-value when diagnosing prostate cancer using 3 tesla MRI: comparison between ultra-high b-value (2000 s/mm²) and standard high b-value (1000 s/mm²).
Kitajima K; Takahashi S; Ueno Y; Yoshikawa T; Ohno Y; Obara M; Miyake H; Fujisawa M; Sugimura K
J Magn Reson Imaging; 2012 Jul; 36(1):198-205. PubMed ID: 22371381
[TBL] [Abstract][Full Text] [Related]
20. Apparent diffusion coefficient for prostate cancer imaging: impact of B values.
Peng Y; Jiang Y; Antic T; Sethi I; Schmid-Tannwald C; Eggener S; Oto A
AJR Am J Roentgenol; 2014 Mar; 202(3):W247-53. PubMed ID: 24555621
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]