629 related articles for article (PubMed ID: 25478820)
21. Biomechanical evaluation of fixation strength among different sizes of pedicle screws using the cortical bone trajectory: what is the ideal screw size for optimal fixation?
Matsukawa K; Yato Y; Imabayashi H; Hosogane N; Abe Y; Asazuma T; Chiba K
Acta Neurochir (Wien); 2016 Mar; 158(3):465-71. PubMed ID: 26769471
[TBL] [Abstract][Full Text] [Related]
22. Pedicle screw augmentation with polyethylene tape: a biomechanical study in the osteoporotic thoracolumbar spine.
Hamasaki T; Tanaka N; Kim J; Okada M; Ochi M; Hutton WC
J Spinal Disord Tech; 2010 Apr; 23(2):127-32. PubMed ID: 20051920
[TBL] [Abstract][Full Text] [Related]
23. Biomechanical evaluation of different surgical procedures in single-level transforaminal lumbar interbody fusion in vitro.
Cao Y; Liu F; Wan S; Liang Y; Jiang C; Feng Z; Jiang X; Chen Z
Clin Biomech (Bristol, Avon); 2017 Nov; 49():91-95. PubMed ID: 28898815
[TBL] [Abstract][Full Text] [Related]
24. Biomechanical Evaluation of Cross Trajectory Technique for Pedicle Screw Insertion: Combined Use of Traditional Trajectory and Cortical Bone Trajectory.
Matsukawa K; Yato Y; Imabayashi H; Hosogane N; Asazuma T; Nemoto K
Orthop Surg; 2015 Nov; 7(4):317-23. PubMed ID: 26792576
[TBL] [Abstract][Full Text] [Related]
25. [Biomechanical stability of unilateral pedicle screw fixation on cadaveric model simulated two-level posterior lumbar interbody fusion].
Dong JW; Feng F; Zhao WD; Rong LM; Liu XM
Zhonghua Wai Ke Za Zhi; 2011 May; 49(5):436-9. PubMed ID: 21733402
[TBL] [Abstract][Full Text] [Related]
26. Cortical bone trajectory screws used to save failed traditional trajectory screws in the osteoporotic lumbar spine and vice versa: a human cadaveric biomechanical study.
Zhang RJ; Li HM; Gao H; Jia CY; Xing T; Dong FL; Shen CL
J Neurosurg Spine; 2019 Mar; 30(6):759-766. PubMed ID: 30849746
[TBL] [Abstract][Full Text] [Related]
27. Biomechanical evaluation of lumbosacral reconstruction techniques for spondylolisthesis: an in vitro porcine model.
Cunningham BW; Lewis SJ; Long J; Dmitriev AE; Linville DA; Bridwell KH
Spine (Phila Pa 1976); 2002 Nov; 27(21):2321-7. PubMed ID: 12438979
[TBL] [Abstract][Full Text] [Related]
28. Primary stiffness of a modified transforaminal lumbar interbody fusion cage with integrated screw fixation: cadaveric biomechanical study.
Keiler A; Schmoelz W; Erhart S; Gnanalingham K
Spine (Phila Pa 1976); 2014 Aug; 39(17):E994-E1000. PubMed ID: 24875958
[TBL] [Abstract][Full Text] [Related]
29. Pedicle screw fixation strength: pullout versus insertional torque.
Inceoglu S; Ferrara L; McLain RF
Spine J; 2004; 4(5):513-8. PubMed ID: 15363421
[TBL] [Abstract][Full Text] [Related]
30. Biomechanical comparison of an interspinous fusion device and bilateral pedicle screw system as additional fixation for lateral lumbar interbody fusion.
Doulgeris JJ; Aghayev K; Gonzalez-Blohm SA; Lee WE; Vrionis FD
Clin Biomech (Bristol, Avon); 2015 Feb; 30(2):205-10. PubMed ID: 25577548
[TBL] [Abstract][Full Text] [Related]
31. Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures.
Norton RP; Milne EL; Kaimrajh DN; Eismont FJ; Latta LL; Williams SK
Spine J; 2014 Aug; 14(8):1734-9. PubMed ID: 24462814
[TBL] [Abstract][Full Text] [Related]
32. Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies.
Inceoğlu S; Montgomery WH; St Clair S; McLain RF
J Neurosurg Spine; 2011 May; 14(5):670-6. PubMed ID: 21388287
[TBL] [Abstract][Full Text] [Related]
33. Biomechanical study of unilateral pedicle screw combined with contralateral translaminar facet screw in transforaminal lumbar interbody fusion.
Luo B; Yan M; Huang J; Duan W; Huang Z; Chen J; Luo Z; Zhu Q; Li M
Clin Biomech (Bristol, Avon); 2015 Aug; 30(7):657-61. PubMed ID: 26043936
[TBL] [Abstract][Full Text] [Related]
34. Dynamic lumbar pedicle screw-rod stabilization: in vitro biomechanical comparison with standard rigid pedicle screw-rod stabilization.
Bozkuş H; Senoğlu M; Baek S; Sawa AG; Ozer AF; Sonntag VK; Crawford NR
J Neurosurg Spine; 2010 Feb; 12(2):183-9. PubMed ID: 20121354
[TBL] [Abstract][Full Text] [Related]
35. Biomechanical Effects of Lateral Inclination C
Zhang L; Wang H
Orthop Surg; 2021 Oct; 13(7):2027-2033. PubMed ID: 34541829
[TBL] [Abstract][Full Text] [Related]
36. Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spines.
Brasiliense LB; Lazaro BC; Reyes PM; Newcomb AG; Turner JL; Crandall DG; Crawford NR
Spine J; 2013 Aug; 13(8):947-56. PubMed ID: 23602373
[TBL] [Abstract][Full Text] [Related]
37. A biomechanical evaluation of three revision screw strategies for failed lateral mass fixation.
Hostin RA; Wu C; Perra JH; Polly DW; Akesen B; Wroblewski JM
Spine (Phila Pa 1976); 2008 Oct; 33(22):2415-21. PubMed ID: 18923316
[TBL] [Abstract][Full Text] [Related]
38. Radiographic feasibility study of cortical bone trajectory and traditional pedicle screw dual trajectories.
Mullin JP; Perlmutter B; Schmidt E; Benzel E; Steinmetz MP
J Neurosurg Spine; 2016 Dec; 25(6):727-732. PubMed ID: 27391396
[TBL] [Abstract][Full Text] [Related]
39. A titanium expandable pedicle screw improves initial pullout strength as compared with standard pedicle screws.
Vishnubhotla S; McGarry WB; Mahar AT; Gelb DE
Spine J; 2011 Aug; 11(8):777-81. PubMed ID: 21802996
[TBL] [Abstract][Full Text] [Related]
40. Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out.
Abshire BB; McLain RF; Valdevit A; Kambic HE
Spine J; 2001; 1(6):408-14. PubMed ID: 14588297
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]