These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 25478903)

  • 21. Solid immunoassay and immunonephelemetric methods for serum C reactive protein (CRP) determination: discrepancy in CRP value for a patient presenting a monoclonal immunoglobulin G.
    Lelong M; Renard MF; Giraudeaux V
    Clin Chim Acta; 1999 Oct; 288(1-2):147-52. PubMed ID: 10529466
    [No Abstract]   [Full Text] [Related]  

  • 22. Oxaprozin and 5-(p-hydroxyphenyl)-5-phenylhydantoin interference in phenytoin immunoassays.
    Datta P
    Clin Chem; 1997 Aug; 43(8 Pt 1):1468-9. PubMed ID: 9267337
    [No Abstract]   [Full Text] [Related]  

  • 23. [An improved processing of turbidimetric immunoassay data by means of a personal computer system].
    Matsuda K
    Rinsho Byori; 1987 Jun; 35(6):621-30. PubMed ID: 3669371
    [No Abstract]   [Full Text] [Related]  

  • 24. False-positive serum tricyclic antidepressant concentrations using fluorescence polarization immunoassay due to the presence of hydroxyzine and cetirizine.
    Dasgupta A; Wells A; Datta P
    Ther Drug Monit; 2007 Feb; 29(1):134-9. PubMed ID: 17333576
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Hydroxyzine and cetirizine interfere with the PENTINA carbamazepine assay but not with the ADVIA CENTEUR carbamazepine assay.
    Dasgupta A; Tso G; Johnson M; Chow L
    Ther Drug Monit; 2010 Feb; 32(1):112-5. PubMed ID: 20040899
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Assay-specific differences in lipemic interference in native and intralipid-supplemented samples.
    Bornhorst JA; Roberts RF; Roberts WL
    Clin Chem; 2004 Nov; 50(11):2197-201. PubMed ID: 15375017
    [No Abstract]   [Full Text] [Related]  

  • 27. Synthesis of new hydrophilic microspheres: optimized carriers for microparticle-enhanced nephelometric immunoassays.
    Marchand J; Varcin P; Riochet D; Montagne P; Cuilliere ML; Duheille J; Pau B
    Biopolymers; 1992 Aug; 32(8):971-80. PubMed ID: 1420980
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Not the usual suspect: Polymeric IgA paraprotein causes false positive results in kinetic interaction of microparticles in solution (KIMS) immunoassays.
    Kemble DJ; Lamothe S; Uhl L
    Clin Biochem; 2021 Jun; 92():82-85. PubMed ID: 33713635
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Factors Affecting Non-Specific Reaction in Latex Agglutination Turbidimetric Immunoassay for Detection of Matrix Metalloproteinase-3].
    Kitaaki S; Hayashi N; Sato I; Watanabe K; Saegusa J; Kawano S
    Rinsho Byori; 2015 Apr; 63(4):427-34. PubMed ID: 26536775
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Laboratory assessment of the acute phase response: using CRP as a model.
    Ritchie RF; Ledue TB
    Methods Mol Biol; 2003; 225():343-52. PubMed ID: 12769501
    [No Abstract]   [Full Text] [Related]  

  • 31. [Determination of C-reactive protein in serum using a fluorescence polarization immunoassay--comparison with the method of kinetic nephelometry (KNM)].
    Liappis N; Jäkel A
    Klin Padiatr; 1987; 199(1):45-7. PubMed ID: 3560764
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Interference in turbidimetric immunoassay for serum C-reactive protein due to serum protein abnormalities an immune complex and rheumatoid factor].
    Ohtake T; Kano S; Watanabe K
    Rinsho Byori; 2000 Aug; 48(8):752-9. PubMed ID: 11064600
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Analytical evaluation of a new liquid immunoturbidimetric assay for the determination of ferritin in serum.
    Molinario R; Autilio C; Pocino K; Daloiso PD; Di Leva S; Zuppi C; Antenucci M
    Clin Chem Lab Med; 2015 Nov; 53(12):e351-3. PubMed ID: 26087064
    [No Abstract]   [Full Text] [Related]  

  • 34. An automated nanoparticle-based homogeneous immunoassay for determining docetaxel concentrations in plasma.
    Cline DJ; Zhang H; Lundell GD; Harney RL; Riaz HK; Jarrah J; Li Y; Miyazaki M; Courtney JB; Baburina I; Salamone SJ
    Ther Drug Monit; 2013 Dec; 35(6):803-8. PubMed ID: 24263639
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Immunoturbidimetric method for determination hemoglobin A1c.
    Grey V; Perlas M; Aebi C
    Clin Chem; 1996 Dec; 42(12):2046-7. PubMed ID: 8969652
    [No Abstract]   [Full Text] [Related]  

  • 36. Improved assay characteristics of an immunoturbidimetric assay for cystatin C.
    Gorst J
    Ann Clin Biochem; 2001 Mar; 38(Pt 2):153. PubMed ID: 11269758
    [No Abstract]   [Full Text] [Related]  

  • 37. Latex-enhanced turbidimetric immunoassay for everolimus in whole blood using the Nanopia TDM everolimus assay with the JCA-BM6010 automatic analyzer.
    Mori K; Kimura S; Matsui M; Suehisa E; Hidaka Y; Fukushima N
    Ther Drug Monit; 2014 Oct; 36(5):677-80. PubMed ID: 25222856
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Immunoglobulin quantitation by latex agglutination immunoassay--new sample treatment to reduce differences in measured values by turbidimetric immunoassay].
    Kubota N
    Rinsho Byori; 2010 Apr; 58(4):387-92. PubMed ID: 20496767
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Correction to 'improved immunoturbidimetric assay for cystatin C'.
    McGuire JB; James TJ; Taylor RP
    Ann Clin Biochem; 2001 Sep; 38(Pt 5):572-3. PubMed ID: 11587141
    [No Abstract]   [Full Text] [Related]  

  • 40. Methods for evaluation of protein components in bronchoalveolar lavage fluids.
    Capelli A; Cerutti CG; Lusuardi M; Colombo M; Donner CF
    Clin Chem; 1993 Oct; 39(10):2201-2. PubMed ID: 8403409
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.