These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 25479031)

  • 1. The aortic reservoir-wave as a paradigm for arterial haemodynamics: insights from three-dimensional fluid-structure interaction simulations in a model of aortic coarctation.
    Segers P; Taelman L; Degroote J; Bols J; Vierendeels J
    J Hypertens; 2015 Mar; 33(3):554-63; discussion 563. PubMed ID: 25479031
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The reservoir wave paradigm discussion.
    Westerhof N; Westerhof BE
    J Hypertens; 2015 Mar; 33(3):458-60. PubMed ID: 25629360
    [No Abstract]   [Full Text] [Related]  

  • 3. Accuracy of Doppler methods for estimating peak-to-peak and peak instantaneous gradients across coarctation of the aorta: An In vitro study.
    Seifert BL; DesRochers K; Ta M; Giraud G; Zarandi M; Gharib M; Sahn DJ
    J Am Soc Echocardiogr; 1999 Sep; 12(9):744-53. PubMed ID: 10477419
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The ebbing tide of the reservoir-wave model.
    Mynard JP; Smolich JJ; Avolio A
    J Hypertens; 2015 Mar; 33(3):461-4. PubMed ID: 25629361
    [No Abstract]   [Full Text] [Related]  

  • 5. The case for the reservoir-wave approach.
    Tyberg JV; Bouwmeester JC; Parker KH; Shrive NG; Wang JJ
    Int J Cardiol; 2014 Mar; 172(2):299-306. PubMed ID: 24485224
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Beyond the aorta: partial transmission of reflected waves from aortic coarctation into supra-aortic branches modulates cerebral hemodynamics and left ventricular load.
    Mynard JP; Kowalski R; Cheung MM; Smolich JJ
    Biomech Model Mechanobiol; 2017 Apr; 16(2):635-650. PubMed ID: 27730475
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Exercise central (aortic) blood pressure is predominantly driven by forward traveling waves, not wave reflection.
    Schultz MG; Davies JE; Roberts-Thomson P; Black JA; Hughes AD; Sharman JE
    Hypertension; 2013 Jul; 62(1):175-82. PubMed ID: 23716581
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The reservoir-wave paradigm introduces error into arterial wave analysis: a computer modelling and in-vivo study.
    Mynard JP; Penny DJ; Davidson MR; Smolich JJ
    J Hypertens; 2012 Apr; 30(4):734-43. PubMed ID: 22278142
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reservoir and reservoir-less pressure effects on arterial waves in the canine aorta.
    Borlotti A; Park C; Parker KH; Khir AW
    J Hypertens; 2015 Mar; 33(3):564-74; discussion 574. PubMed ID: 25462708
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computational models of aortic coarctation in hypoplastic left heart syndrome: considerations on validation of a detailed 3D model.
    Biglino G; Corsini C; Schievano S; Dubini G; Giardini A; Hsia TY; Pennati G; Taylor AM;
    Int J Artif Organs; 2014 May; 37(5):371-81. PubMed ID: 24968194
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Wave intensity analysis and the development of the reservoir-wave approach.
    Tyberg JV; Davies JE; Wang Z; Whitelaw WA; Flewitt JA; Shrive NG; Francis DP; Hughes AD; Parker KH; Wang JJ
    Med Biol Eng Comput; 2009 Feb; 47(2):221-32. PubMed ID: 19189147
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mathematical, numerical and experimental study in the human aorta with coexisting models of bicuspid aortic stenosis and coarctation of the aorta.
    Keshavarz-Motamed Z; Garcia J; Kadem L
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():182-5. PubMed ID: 22254280
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation: comparison with young healthy volunteers.
    Rengier F; Delles M; Eichhorn J; Azad YJ; von Tengg-Kobligk H; Ley-Zaporozhan J; Dillmann R; Kauczor HU; Unterhinninghofen R; Ley S
    Int J Cardiovasc Imaging; 2015 Apr; 31(4):823-30. PubMed ID: 25645544
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Uncertainty Quantification for Non-invasive Assessment of Pressure Drop Across a Coarctation of the Aorta Using CFD.
    Brüning J; Hellmeier F; Yevtushenko P; Kühne T; Goubergrits L
    Cardiovasc Eng Technol; 2018 Dec; 9(4):582-596. PubMed ID: 30284186
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of arterial waves derived by classical wave separation and wave intensity analysis in a model of aortic coarctation.
    van den Wijngaard JP; Siebes M; Westerhof BE
    Med Biol Eng Comput; 2009 Feb; 47(2):211-20. PubMed ID: 18763006
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coarctation of the aorta--a theoretical and experimental analysis of the effects of a centrally located arterial stenosis.
    Engvall J; Ask P; Loyd D; Wranne B
    Med Biol Eng Comput; 1991 May; 29(3):291-6. PubMed ID: 1943261
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reservoir pressure analysis of aortic blood pressure: an in-vivo study at five locations in humans.
    Narayan O; Parker KH; Davies JE; Hughes AD; Meredith IT; Cameron JD
    J Hypertens; 2017 Oct; 35(10):2025-2033. PubMed ID: 28582283
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computational fluid dynamic simulations of aortic coarctation comparing the effects of surgical- and stent-based treatments on aortic compliance and ventricular workload.
    Coogan JS; Chan FP; Taylor CA; Feinstein JA
    Catheter Cardiovasc Interv; 2011 Apr; 77(5):680-91. PubMed ID: 21061250
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Elimination of Transcoarctation Pressure Gradients Has No Impact on Left Ventricular Function or Aortic Shear Stress After Intervention in Patients With Mild Coarctation.
    Keshavarz-Motamed Z; Rikhtegar Nezami F; Partida RA; Nakamura K; Staziaki PV; Ben-Assa E; Ghoshhajra B; Bhatt AB; Edelman ER
    JACC Cardiovasc Interv; 2016 Sep; 9(18):1953-65. PubMed ID: 27659574
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Insights into the effect of aortic compliance on Doppler diastolic flow patterns seen in coarctation of the aorta: a numeric study.
    DeGroff CG; Orlando W; Shandas R
    J Am Soc Echocardiogr; 2003 Feb; 16(2):162-9. PubMed ID: 12574743
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.