These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

44 related articles for article (PubMed ID: 25479882)

  • 1. The myth of data acquisition rate.
    Felinger A; Kilár A; Boros B
    Anal Chim Acta; 2015 Jan; 854():178-82. PubMed ID: 25479882
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [High-resolution functional cardiac MR imaging using density-weighted real-time acquisition and a combination of compressed sensing and parallel imaging for image reconstruction].
    Wech T; Gutberlet M; Greiser A; Stäb D; Ritter CO; Beer M; Hahn D; Köstler H
    Rofo; 2010 Aug; 182(8):676-81. PubMed ID: 20563957
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Compressed sensing for reduction of noise and artefacts in direct PET image reconstruction.
    Richter D; Basse-Lüsebrink TC; Kampf T; Fischer A; Israel I; Schneider M; Jakob PM; Samnick S
    Z Med Phys; 2014 Mar; 24(1):16-26. PubMed ID: 23756331
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Digital timing: sampling frequency, anti-aliasing filter and signal interpolation filter dependence on timing resolution.
    Cho S; Grazioso R; Zhang N; Aykac M; Schmand M
    Phys Med Biol; 2011 Dec; 56(23):7569-83. PubMed ID: 22086164
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low frequency noise elimination technique for 24-bit Σ-Δ data acquisition systems.
    Qu SB; Robert O; Lognonné P; Zhou ZB; Yang SQ
    Rev Sci Instrum; 2015 Mar; 86(3):034708. PubMed ID: 25832259
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Acquisition of low-frequency signals immersed in noise by random sampling and finite impulse response filters.
    Carrica DO; Petrocelli R; Benedetti M; Funes MA
    Rev Sci Instrum; 2007 Apr; 78(4):044702. PubMed ID: 17477686
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulsed laser noise analysis and pump-probe signal detection with a data acquisition card.
    Werley CA; Teo SM; Nelson KA
    Rev Sci Instrum; 2011 Dec; 82(12):123108. PubMed ID: 22225200
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Shape-preserving preprocessing for human pulse signals based on adaptive parameter determination.
    Wang H; Wang X; Deller JR; Fu J
    IEEE Trans Biomed Circuits Syst; 2014 Aug; 8(4):594-604. PubMed ID: 24158509
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Time-resolved 3D pulmonary perfusion MRI: comparison of different k-space acquisition strategies at 1.5 and 3 T.
    Attenberger UI; Ingrisch M; Dietrich O; Herrmann K; Nikolaou K; Reiser MF; Schönberg SO; Fink C
    Invest Radiol; 2009 Sep; 44(9):525-31. PubMed ID: 19652608
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of gradient descent adaptive algorithms to remove common mode artifact for improvement of cardiovascular signal quality.
    Ciaccio EJ; Micheli-Tzanakou E
    Ann Biomed Eng; 2007 Jul; 35(7):1146-55. PubMed ID: 17401690
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A simple and versatile data acquisition system for software coincidence and pulse-height discrimination in 4πβ-γ coincidence experiments.
    Kawada Y; Yamada T; Unno Y; Yunoki A; Sato Y; Hino Y
    Appl Radiat Isot; 2012 Sep; 70(9):2031-6. PubMed ID: 22429558
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardinal series to filter oversampled truncated magnetic resonance signals.
    Rodts S; Bytchenkoff D; Fen-Chong T
    J Magn Reson; 2010 May; 204(1):64-75. PubMed ID: 20303807
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel algorithm for the reduction of undersampling artefacts in magnetic resonance images.
    Placidi G; Sotgiu A
    Magn Reson Imaging; 2004 Nov; 22(9):1279-87. PubMed ID: 15607099
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nyquist interpolation improves neuron yield in multiunit recordings.
    Blanche TJ; Swindale NV
    J Neurosci Methods; 2006 Jul; 155(1):81-91. PubMed ID: 16481043
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Interpolation methods for time-delay estimation using cross-correlation method for blood velocity measurement.
    Lai X; Torp H
    IEEE Trans Ultrason Ferroelectr Freq Control; 1999; 46(2):277-90. PubMed ID: 18238424
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accelerated radial Fourier-velocity encoding using compressed sensing.
    Hilbert F; Wech T; Hahn D; Köstler H
    Z Med Phys; 2014 Sep; 24(3):190-200. PubMed ID: 24239136
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Digital-signal-processor-based dynamic imaging system for optical tomography.
    Lasker JM; Masciotti JM; Schoenecker M; Schmitz CH; Hielscher AH
    Rev Sci Instrum; 2007 Aug; 78(8):083706. PubMed ID: 17764328
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardinal series to restore NMR-signals dominated by strong inhomogeneous broadening.
    Rodts S; Bytchenkoff D
    J Magn Reson; 2011 Sep; 212(1):26-39. PubMed ID: 21737327
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Suppression of power-line interference by analog notch filtering in the ECG signal for heart rate variability analysis: to do or not to do?
    Hejjel L
    Med Sci Monit; 2004 Jan; 10(1):MT6-13. PubMed ID: 14704641
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Whole-heart cine MRI in a single breath-hold--a compressed sensing accelerated 3D acquisition technique for assessment of cardiac function.
    Wech T; Pickl W; Tran-Gia J; Ritter C; Beer M; Hahn D; Köstler H
    Rofo; 2014 Jan; 186(1):37-41. PubMed ID: 23996623
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.