These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

183 related articles for article (PubMed ID: 25484345)

  • 1. The "neuro-mapping locator" software. A real-time intraoperative objective paraesthesia mapping tool to evaluate paraesthesia coverage of the painful zone in patients undergoing spinal cord stimulation lead implantation.
    Guetarni F; Rigoard P
    Neurochirurgie; 2015 Mar; 61 Suppl 1():S90-8. PubMed ID: 25484345
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel, objective, quantitative method of evaluation of the back pain component using comparative computerized multi-parametric tactile mapping before/after spinal cord stimulation and database analysis: the "Neuro-Pain't" software.
    Rigoard P; Nivole K; Blouin P; Monlezun O; Roulaud M; Lorgeoux B; Bataille B; Guetarni F
    Neurochirurgie; 2015 Mar; 61 Suppl 1():S99-S108. PubMed ID: 25484344
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Franco-Canadian multicolumn spinal cord stimulation prospective study: a subgroup analysis focusing on the decisive role of lead positioning.
    Delmotte A; Jacques L; Kumar K; Poon K; Monlezun O; Roulaud M; Prevost A; Munson R; Guetarni F; Bataille B; Rigoard P
    Neurochirurgie; 2015 Mar; 61 Suppl 1():S83-9. PubMed ID: 25245918
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multicolumn spinal cord stimulation for significant low back pain in failed back surgery syndrome: design of a national, multicentre, randomized, controlled health economics trial (ESTIMET Study).
    Roulaud M; Durand-Zaleski I; Ingrand P; Serrie A; Diallo B; Peruzzi P; Hieu PD; Voirin J; Raoul S; Page P; Fontaine D; Lantéri-Minet M; Blond S; Buisset N; Cuny E; Cadenne M; Caire F; Ranoux D; Mertens P; Naous H; Simon E; Emery E; Gadan B; Regis J; Sol JC; Béraud G; Debiais F; Durand G; Guetarni Ging F; Prévost A; Brandet C; Monlezun O; Delmotte A; d'Houtaud S; Bataille B; Rigoard P
    Neurochirurgie; 2015 Mar; 61 Suppl 1():S109-16. PubMed ID: 25456442
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An algorithmic programming approach for back pain symptoms in failed back surgery syndrome using spinal cord stimulation with a multicolumn surgically implanted epidural lead: a multicenter international prospective study.
    Rigoard P; Jacques L; Delmotte A; Poon K; Munson R; Monlezun O; Roulaud M; Prevost A; Guetarni F; Bataille B; Kumar K
    Pain Pract; 2015 Mar; 15(3):195-207. PubMed ID: 24571497
    [TBL] [Abstract][Full Text] [Related]  

  • 6. "MAST" prospective study: value of minimal access spine technologies technique for multicolumn spinal cord stimulation surgical lead implantation in the context of a French multicentre randomized controlled trial (ESTIMET study).
    Monlezun O; Voirin J; Roulaud M; Ingrand P; Veyrieras C; Brandet C; Bataille B; Guetarni F; Prévost A; Rigoard P;
    Neurochirurgie; 2015 Mar; 61 Suppl 1():S125-30. PubMed ID: 25224961
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A prospective study evaluating sleep quality in Failed Back Surgery Syndrome patients treated by multicolumn spinal cord stimulation: study design protocol and presentation of the study population.
    Monlezun O; Lode-Kolz K; Roulaud M; Paquereau J; Ingrand P; Veyrieras C; Brandet C; Guetarni F; Prévost A; Bataille B; Rigoard P;
    Neurochirurgie; 2015 Mar; 61 Suppl 1():S117-24. PubMed ID: 25245920
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Implanter's Integrated Information (I3) System: An Aid for Spinal Cord Stimulation Procedures.
    Meier K; Knudsen ALH; Boudreau SA; Sørensen JCH
    Neuromodulation; 2019 Apr; 22(3):290-294. PubMed ID: 30325079
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nonawake vs Awake Placement of Spinal Cord Stimulators: A Prospective, Multicenter Study Comparing Safety and Efficacy.
    Falowski SM; Sharan A; McInerney J; Jacobs D; Venkatesan L; Agnesi F
    Neurosurgery; 2019 Jan; 84(1):198-205. PubMed ID: 29547957
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraoperative Motor Evoked Responses to Double-Train Paradigm Stimulation for Guiding Lead Placement and Postoperative Programming in Spinal Cord Stimulation for Pain.
    Schlaeppi JA; Schreen R; Mija R; Nowacki A; Pollo C; Seidel K
    Neuromodulation; 2023 Jan; 26(1):147-156. PubMed ID: 35599160
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Paresthesia-Independence: An Assessment of Technical Factors Related to 10 kHz Paresthesia-Free Spinal Cord Stimulation.
    De Carolis G; Paroli M; Tollapi L; Doust MW; Burgher AH; Yu C; Yang T; Morgan DM; Amirdelfan K; Kapural L; Sitzman BT; Bundschu R; Vallejo R; Benyamin RM; Yearwood TL; Gliner BE; Powell AA; Bradley K
    Pain Physician; 2017 May; 20(4):331-341. PubMed ID: 28535555
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Duration of intra-operative stimulation as a predictor of success of spinal cord stimulation for chronic pain syndromes.
    Al-Jehani H; Essawi W; Jacques L
    Turk Neurosurg; 2012; 22(5):588-90. PubMed ID: 23015335
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Spinal cord stimulation and failed back surgery syndrome. Clinical results with laminectomy electrodes].
    García March G; Bordes V; Roldán P; Real L; González Darder JM
    Neurocirugia (Astur); 2015; 26(2):78-83. PubMed ID: 25455763
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of Paresthesia Mapping With Anatomic Placement in Burst Spinal Cord Stimulation: Long-Term Results of the Prospective, Multicenter, Randomized, Double-Blind, Crossover CRISP Study.
    Al-Kaisy A; Baranidharan G; Sharon H; Palmisani S; Pang D; Will O; Wesley S; Crowther T; Ward K; Castino P; Raza A; Pathak YJ; Agnesi F; Yearwood T
    Neuromodulation; 2022 Jan; 25(1):85-93. PubMed ID: 35041591
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biplanar Fluoroscopy-Guided Percutaneous Lead Implantation for Spinal Cord Stimulation: Technical Note.
    Lawson McLean A; Frank S; Staribacher D; Kalff R; Reichart R
    World Neurosurg; 2017 Sep; 105():760-764. PubMed ID: 28645599
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Back pain: a real target for spinal cord stimulation?
    Rigoard P; Delmotte A; D'Houtaud S; Misbert L; Diallo B; Roy-Moreau A; Durand S; Royoux S; Giot JP; Bataille B
    Neurosurgery; 2012 Mar; 70(3):574-84; discussion 584-5. PubMed ID: 21937929
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The Added Value of Intraoperative Hypnosis during Spinal Cord Stimulation Lead Implantation under Awake Anesthesia in Patients Presenting with Refractory Chronic Pain.
    Wood C; Martiné G; Espagne-Dubreuilh G; Le Goff K; Moens M; Goudman L; Baron S; David R; Naïditch N; Billot M; Rigoard P
    Medicina (Kaunas); 2022 Feb; 58(2):. PubMed ID: 35208543
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical Paresthesia Atlas Illustrates Likelihood of Coverage Based on Spinal Cord Stimulator Electrode Location.
    Taghva A; Karst E; Underwood P
    Neuromodulation; 2017 Aug; 20(6):582-588. PubMed ID: 28370724
    [TBL] [Abstract][Full Text] [Related]  

  • 19. New advancements in spinal cord stimulation for chronic pain management.
    Xu J; Liu A; Cheng J
    Curr Opin Anaesthesiol; 2017 Dec; 30(6):710-717. PubMed ID: 28938297
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spinal Cord Stimulation via Percutaneous and Open Implantation: Systematic Review and Meta-Analysis Examining Complication Rates.
    Blackburn AZ; Chang HH; DiSilvestro K; Veeramani A; McDonald C; Zhang AS; Daniels A
    World Neurosurg; 2021 Oct; 154():132-143.e1. PubMed ID: 34343680
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.