These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

411 related articles for article (PubMed ID: 25491823)

  • 21. Determination of thiocyanate ions at nanolevel in real samples using coated graphite electrode based on synthesised macrocyclic Zn(II) complex.
    Singh P; Singh AK
    Anal Bioanal Chem; 2011 Jun; 400(7):2261-9. PubMed ID: 21475945
    [TBL] [Abstract][Full Text] [Related]  

  • 22. PVC membrane and coated graphite potentiometric sensors based on Et4todit for selective determination of samarium(III).
    Shamsipur M; Hosseini M; Alizadeh K; Talebpour Z; Mousavi MF; Ganjali MR; Arca M; Lippolis V
    Anal Chem; 2003 Nov; 75(21):5680-6. PubMed ID: 14588005
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Chromium(III) selective membrane sensors based on Schiff bases as chelating ionophores.
    Singh AK; Gupta VK; Gupta B
    Anal Chim Acta; 2007 Feb; 585(1):171-8. PubMed ID: 17386662
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The anion recognition properties of a novel hydrazone based on colorimetric and potentiometric studies.
    Singhal D; Gupta N; Singh AK
    Mater Sci Eng C Mater Biol Appl; 2016 Jan; 58():548-57. PubMed ID: 26478343
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Selective electrochemical sensor for copper (II) ion based on chelating ionophores.
    Singh AK; Mehtab S; Jain AK
    Anal Chim Acta; 2006 Aug; 575(1):25-31. PubMed ID: 17723567
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Construction of a new selective coated disk electrode for Ag (I) based on modified polypyrrole-carbon nanotubes composite with new lariat ether.
    Abbaspour A; Tashkhourian J; Ahmadpour S; Mirahmadi E; Sharghi H; Khalifeh R; Shahriyari MR
    Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():326-33. PubMed ID: 24268265
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cobalt(II)-selective membrane sensor based on a [Me2(13)dieneN4] macrocyclic cobalt complex.
    Singh AK; Saxena P; Mehtab S; Panwar A
    Anal Bioanal Chem; 2006 Aug; 385(7):1342-6. PubMed ID: 16794813
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Selective uranyl ion detection by polymeric ion-selective electrodes based on salphenH2 derivatives.
    Kim DW; Park KW; Yang MH; Kim TH; Mahajan RK; Kim JS
    Talanta; 2007 Nov; 74(2):223-8. PubMed ID: 18371633
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II).
    Gupta VK; Singh AK; Al Khayat M; Gupta B
    Anal Chim Acta; 2007 May; 590(1):81-90. PubMed ID: 17416226
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Preparation of a new chromium(III) selective electrode based on 1-[(2-hydroxy ethyl) amino]-4-methyl-9H-thioxanthen-9-one as a neutral carrier.
    Ghaedi M; Shokrollahi A; Salimibeni AR; Noshadi S; Joybar S
    J Hazard Mater; 2010 Jun; 178(1-3):157-63. PubMed ID: 20362393
    [TBL] [Abstract][Full Text] [Related]  

  • 31. ppt level detection of samarium(III) with a coated graphite sensor based on an antibiotic.
    Ganjali MR; Rezapour M; Pourjavid MR; Haghgoo S
    Anal Sci; 2004 Jul; 20(7):1007-11. PubMed ID: 15293392
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Perchlorate-selective polymeric membrane electrode based on bis(dibenzoylmethanato)cobalt(II) complex as a neutral carrier.
    Rezaei B; Meghdadi S; Bagherpour S
    J Hazard Mater; 2009 Jan; 161(2-3):641-8. PubMed ID: 18486336
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Optimization of polymeric triiodide membrane electrode based on clozapine-triiodide ion-pair using experimental design.
    Farhadi K; Bahram M; Shokatynia D; Salehiyan F
    Talanta; 2008 Jul; 76(2):320-6. PubMed ID: 18585284
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Optimization of a new polymeric chromium (III) membrane electrode based on methyl violet by using experimental design.
    Kazemi SY; Hamidi As; Asanjarani N; Zolgharnein J
    Talanta; 2010 Jun; 81(4-5):1681-7. PubMed ID: 20441958
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A Schiff base complex of Zn(II) as a neutral carrier for highly selective PVC membrane sensors for the sulfate ion.
    Shamsipur M; Yousefi M; Hosseini M; Ganjali MR; Sharghi H; Naeimi H
    Anal Chem; 2001 Jul; 73(13):2869-74. PubMed ID: 11467529
    [TBL] [Abstract][Full Text] [Related]  

  • 36. 8-hydroxyquinoline based neutral tripodal ionophore as a copper (II) selective electrode and the effect of remote substitutents on electrode properties.
    Mittal SK; Kumar A; Gupta N; Kaur S; Kumar S
    Anal Chim Acta; 2007 Feb; 585(1):161-70. PubMed ID: 17386661
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A 9,10-anthraquinone derivative having two propenyl arms as a neutral ionophore for highly selective and sensitive membrane sensors for copper(II) ion.
    Shamsipur M; Avanes A; Javanbakht M; Ganjali MR; Sharghi H
    Anal Sci; 2002 Aug; 18(8):875-9. PubMed ID: 12200832
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A Ho(III) potentiometric polymeric membrane sensor based on a new four dentate neutral ion carrier.
    Zamani HA; Zanganeh-Asadabadi A; Rohani M; Zabihi MS; Fadaee J; Ganjali MR; Faridbod F; Meghdadi S
    Mater Sci Eng C Mater Biol Appl; 2013 Mar; 33(2):984-8. PubMed ID: 25427515
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Polymeric membrane ion-selective electrode for determination of bismuth (III) in pharmaceutical substances.
    Kharitonov S
    J Pharm Biomed Anal; 2002 Sep; 30(2):181-7. PubMed ID: 12191702
    [TBL] [Abstract][Full Text] [Related]  

  • 40. PVC membrane, coated-wire, and carbon-paste ion-selective electrodes for potentiometric determination of galantamine hydrobromide in physiological fluids.
    Abdel-Haleem FM; Saad M; Barhoum A; Bechelany M; Rizk MS
    Mater Sci Eng C Mater Biol Appl; 2018 Aug; 89():140-148. PubMed ID: 29752082
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.